©Elation Professionals® - www.elationlighting.com - TVL4000 User Manual Page 11
©Elation Professionals® - www.elationlighting.com - TVL4000 User Manual Page 12
Dimmer Mode 3 (Inverse Square Law) - Provides finer dimming
control at lower intensities.
Dimmer Mode 4 (S-Curve) - Similar to Linear dimming with finer
dimming control at mid level intensities.
3. Press the UP or DOWN buttons to find your desired show
mode and press ENTER, then press and hold the MENU button
for at least 3 seconds to confirm.
LED -
With this function you can have the LED display
turn off after 20 seconds.
1. Press the MENU button until “
LED
” is displayed, press
ENTER.
2. The display will show either “
ON”
or
“OFF
”. Press the UP or
DOWN buttons to select “
ON
” to keep the LED display On at all
times, or “
OFF
” so that the LED display turns off after 20 sec-
onds.
3. Press ENTER to confirm.
DISP
-
This function will reverse the display 180º.
1. Press the MENU button until “
DISP
” is displayed, press
ENTER.
2. Press the UP button to select “
DISP
” to activate this function,
or “
DSIP
” to deactivate this function.
3. Press ENTER to confirm.
TEST
- This function will run a self test program.
1. Tap the MENU button until “
TEST
” is displayed, press ENTER.
2. The fixture will now run a self test program. To stop the self
test press either the MENU or ENTER button.
TVL4000 System Menu
1. Press the MENU button until “
MANU
” is displayed, press
ENTER. “
LED1
”, “
LED2
” or “
DINN
” will be displayed. LED 1 is
warm white, LED 2 is cool white, and DIMM is the master
dimmer for this mode.
2. Use the UP or DOWN buttons to scroll to the color you
would like adjust first, and press ENTER.
3. Use the UP or DOWN buttons to adjust the intensity of the
chosen color, and press ENTER after the adjustment.
4. Continue to make adjustments to the two colors until your
desired color is reached. Once your desired color is reached do
not leave this mode.
5. To leave this mode, press the MENU button. Once you leave
this mode, all settings will be reset.
BLND -
Blackout or Stand by mode.
1. Press the MENU button until “
BLND
” is displayed, press
ENTER. Either Yes or No will be displayed.
2. To activate Blackout press the UP or DOWN buttons until Yes
is displayed, press ENTER to confim and exit. The fixture will
now be in Blackout mode. To deactivate Blackout mode, select
No and press Enter.
DIND -
In this mode you can select and set the dimmer
curve.
1. Press the MENU button until “
DIND
” is displayed, press ENTER.
2. “
DI X
” will be displayed, “X” representing the displayed dimmer
mode. The modes are explained below.
Dimmer Mode 1 (Linear) - Steady, even increase in dimming.
Dimmer Mode 2 (Square Law) - Provides finer dimming control
near full intensity.
TVL4000