©Elation Professionals®  -  www.elationlighting.com  - TVL4000 User Manual Page 6

©Elation Professionals®  -  www.elationlighting.com  - TVL4000 User Manual Page 5

Power Supply:

 The Elation Professionals

®

 TVL4000 contains an 

automatic voltage switch, which will auto sense the voltage when it 

is plugged into the power source. With this switch there is no need 

to worry about the correct power voltage, this unit can be plugged in 

anywhere. Also be sure to only use the included I.E.C. power cable 

supplied with the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The TVL4000 has 3 DMX Channel Modes; Mode 1 has 2 

Channels, Mode 2 has 2 Channels, and Mode 3 has 3 Channels. The 

DMX address is set electronically using the controls on the rear of the 

unit. Your unit and your DMX controller require a 

approved DMX-512 110 Ohm Data cable for data 

input and data output. We recommend Accu-Cable 

DMX cables. If you are making your own cables, be 

sure to use standard 110-120 Ohm shielded cable 

(This cable may be purchased at almost all pro-

fessional sound and lighting stores). Your cables 

should be made with a male and female XLR con-

nector on either end of the cable. Also remember 

 TVL4000                                                                    Set Up

Figure 1

 TVL4000                                                                    Set Up

Notice:

 Be sure to follow figures two and three when making your 

own cables. Do not use the ground post on the XLR connector. Do 

not connect the cable’s shield conductor to the ground lug or allow 

the shield conductor to come in contact with the XLR’s outer casing. 

Grounding the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

that DMX cable must be daisy chained and cannot be split.

Содержание TVL4000

Страница 1: ... TVL4000 has 3 DMX channel modes Mode 1 is 2 DMX Channels Mode 2 is 2 DMX Channels and Mode 3 is 3 DMX Channels This fix ture has two operating modes manual mode or DMX controlled The TVL4000 can be run as stand alone unit or in a master slave configu ration Customer Support Elation Professionals provides a toll free cus tomer support line to provide help and to answer any question should you enco...

Страница 2: ...liance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance TVL4000 Safety Precautions Elation Professionals www elationlighting com TVL4000 User Manual Page 4 Elation Professionals www elationlighting com TVL4000 User Manual Page 3 3 DMX Channel Modes Mode 1 is 2 DMX Channels Mode 2 is 2 DMX Channels Mode ...

Страница 3: ...12 110 Ohm Data cable for data input and data output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all pro fessional sound and lighting stores Your cables should be made with a male and female XLR con nector on either end of the cable Also remember TVL4000 Set Up Figure 1 TVL4000 Set Up ...

Страница 4: ... XLR to 5 Pin XLR Conversion TVL4000 Set Up TVL4000 Control Panel 1 Display To show the various menus and the selected functions 2 Indicator LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode COLOR TEMP Flashing Max power consumption of CW WW 3 Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected function...

Страница 5: ...you have found your desired DMX address press ENTER and connect your DMX Controller CHND This will let you switch between the 3 DMX Chan nel Modes 1 Press the MENU button until CHND is displayed press ENTER Either MOD 1 2 Channel Mode MOD 2 2 Channel Mode or MOD 3 3 Channel Mode will be displayed 2 Press the UP or DOWN buttons to choose your desired DMX mode and press ENTER to confim and exit SLND...

Страница 6: ...t program To stop the self test press either the MENU or ENTER button TVL4000 System Menu 1 Press the MENU button until MANU is displayed press ENTER LED1 LED2 or DINN will be displayed LED 1 is warm white LED 2 is cool white and DIMM is the master dimmer for this mode 2 Use the UP or DOWN buttons to scroll to the color you would like adjust first and press ENTER 3 Use the UP or DOWN buttons to ad...

Страница 7: ...s will allow you to create your own programs 4 Follow the instructions on page 9 to set the DMX address 5 For longer cable runs more than a 100 feet use a terminator on the last fixture 6 For help operating in DMX mode consult the manual included with your DMX controller Manual Mode This mode allows the user to adjust the color intensity to create their own desired color temperature 1 Press the ME...

Страница 8: ... to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp out put 1 Use normal glass clean...

Страница 9: ... not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include mainte nance cleaning or periodic check up During the period specified above Ela tion Professionals will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in mate rial or workmanship The sole...

Страница 10: ...e DMX 3 DMX Channel Modes 2 DMX Channels 2 DMX Channels 3 Channels Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains a automatic volt age switch which will auto sense the voltage when it is plugged into the power source American DJ Europe Junostraat 2 6468 EW Kerkrade Netherlands service adjgroup eu www americandj eu Tel 31 45 546 85 00 F...

Отзывы: