Elation TVL1000 Скачать руководство пользователя страница 3

©Elation Pr

o

fessionals®  -  www.elationlighting.com  - TVL1000 Instruction Manual Page 6

©Elation Pr

o

fessionals®  -  www.elationlighting.com  - TVL1000 Instruction Manual Page 5

Power Supply:

 The Elation Professionals

®

 TVL1000 contains an 

electronic ballast, which will auto sense the voltage when it is plugged 

into the power source. With the electronic ballast you do not need to 

worry about wall voltage, this unit can be plugged in anywhere.  Also 

be sure to only use the included I.E.C. power cable supplied with the 

unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The TVL1000 3 DMX channel modes. The DMX address 

is set electronically using the controls on the side of the unit. Your unit 

and your DMX controller require a approved DMX-

512 110 Ohm Data cable for data input and data 

output. We recommend Accu-Cable DMX cables. 

If you are making your own cables, be sure to use 

standard 110-120 Ohm shielded cable (This cable 

may be purchased at almost all professional sound 

and lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

 TVL1000 

 

                                                     Set Up

Figure 1

 TVL1000 

 

 

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Содержание TVL1000

Страница 1: ...a 3 Channel Mode The fixture has two operating modes manual mode or DMX controlled The TVL1000 can only be run as stand alone unit This unit is suitable for theaters studios retail stores and other similar locations For best results use fog or special effects smoke to enhance the light projec tions Customer Support Elation Professionals provides a toll free cus tomer support line to provide help a...

Страница 2: ...len or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance TVL1000 Safety Precautions Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 4 Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 3 3 DMX Channel Mode...

Страница 3: ...ire a approved DMX 512 110 Ohm Data cable for data input and data output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must b...

Страница 4: ...d stays lit it means the battery is at full charge When using the battery power the indicator light will not bet lit If the remaining battery power is less then 16 the indicator will blink fast reminding you that the battery is low and that it needs to be charged 4 Dimmer adjust knob Adjust lightness for the unit from 0 100 5 Color temperature adjustment Adjust the color temperature from 3200k to ...

Страница 5: ...econds the fixture will automatically confirm and lock the change into the system memory To exit without making any changes press the MENU button ADDR DMX Address Setting 1 First set the unit to your desired DMX Channel mode 2 To set your address tap either the MENU UP or DOWN buttons until ADDR is displayed press ENTER 1 will now be displayed and flashing 3 Press the UP or DOWN buttons to find yo...

Страница 6: ... until MANU is displayed press ENTER LED1 LED2 or DINN will be displayed LED 1 is warm white LED 2 is cool white and DIMM is the master dimmer for this mode 2 Use the UP or DOWN buttons to scroll to the color you would like adjust first and press ENTER 3 Use the UP or DOWN buttons to adjust the intensity of the chosen color and press ENTER after the adjustment 4 Continue to make adjustments to the...

Страница 7: ...ws the user to adjust the color intensity to create their own desired color temperature 1 Press the MENU button until MANU is displayed and press ENTER 2 Follow the instructions on pages 10 11 to operate this mode 3 You can also use the Color Adjust Knob and Dimmer Knob to manually create your desired color temperature Please see the Control Panel on page 8 TVL1000 Universal DMX Control TVL1000 Sy...

Страница 8: ...um After 12 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures Powered via battery power With this feature you can connect the fixtures to one another using the IEC input and output sock ets The quantity that can be connected is 5 fixtures maximum After 5 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixt...

Страница 9: ...oth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in TVL1000 Fuse Replacement First unplug the power Locate and remove the unit s power cord Once the cord has been removed located the fuse holder located inside the power socket Insert a flat head screw driver into the power s...

Страница 10: ...liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professionals concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals f...

Отзывы: