  Protron Color™    

 

        Warranty Registration

©

Elation Professional

® - 

www.elationlighting.com - Protron Color™ Instruction Manual Page 3

The  Protron  Color™  carries  a  two  year  (730  days)  limited  warranty. 
Please fill out the enclosed warranty card to validate your purchase. 
All  returned  service  items  whether  under  warranty  or  not,  must  be 
freight pre-paid and accompany a return authorization (R.A.) number. 
The R.A. number must be clearly written on the outside of the return 
package. A brief description of the problem as well as the R.A. num-
ber must also be written down on a piece of paper and included in 
the shipping container. If the unit is under warranty, you must provide 
a copy of your proof of purchase invoice. You may obtain a R.A. num-
ber by contacting customer support at (323) 582-3322.

  Protron Color™    

 

         Cleaning Instructions

Due  to  fog  residue,  smoke,  and  dust  cleaning  the  fixture  should  be 
carried out periodically to optimize light output.  
1.  Use normal glass cleaner and a soft cloth to wipe down the out-
 

side casing every 20 days.

2.  Use normal glass cleaner with a soft cloth to wipe down the inside 
 

reflector and lens every 30-60 days.

3.  Always be sure to dry all parts completely before plugging the 
 

unit back in.

4.  Frequent cleaning the unit will extend lamp life and ensure the fix-
 

tures reliability.

Cleaning frequency depends on the environment in which the fixture 
operates  (I.e.  smoke,  fog  residue,  dust,  dew).  In  heavy  use  we  rec-
ommend  cleaning  on  a  monthly  basis.  Periodic  cleaning  will  ensure 
longevity, and crisp beam output.

  Protron Color™    

 

 

       Safety Warnings

Safety  Issues:

 

This  unit  may  blow  a  fuse  if  the  maximum  allotted 

load of 20 amps (10 amps 220v version) is reached. If the fuse needs 
replacement, always replace the fuse with same exact type that was 
remove, unless otherwise instructed by an authorized Elation Profes-
sional

®

 service technician. Use of a different type fuse from that which 

is  recommended  may  cause  fire  or  electric  shock  and  will  void  the 
manufactures warranty.

•  To reduce the risk of electrical shock or fire, do not expose this unit
     rain or moisture.
•   Do not spill water or other liquids  into or on to your unit.
•   Do not attempt to remove or break off the ground prong from the
    electrical cord. This prong is used to reduce the risk of electrical  
   shock and fire in case of an internal short. Do not attempt to oper-
   ate this unit if the power cord has been frayed or broken.
•   Disconnect from main power before making any type of connection.
•   Do not remove the cover under any conditions. There are no user  
   serviceable parts inside.
•   Always be sure to mount this unit in an area that will allow proper  
   ventilation. Allow about 6” (15cm) between this device and a wall.
•   Do not attempt to operate this unit, if it becomes damaged.
•   This unit is intended for indoor use only, use of this product out-
   doors voids all warranties.
•   During long periods of non-use, disconnect the unit’s main power.
•   Always mount this unit in safe and stable matter.
•   Power cords should be routed so they are not likely to be walked  
   on, pinched by items placed upon or against them.
• Cleaning -The fixture should be cleaned only as recommended by  
   the manufacturer. See page 3 for cleaning details.
•   Heat -The appliance should be situated away from heat sources  
   such as radiators, heat registers, stoves, or other appliances    
   (including amplifiers) that produce heat.
•   The fixture should be serviced by qualified service personnel when:
    A.  The power-supply cord or the plug has been damaged.
    B.   Objects have fallen, or liquid has been spilled into the unit.
    C.  The unit has been exposed to rain or water.
    D.   The unit does not appear to operate normally or exhibits a  
         marked change in performance.

  Protron Color™    

 

          

         Features

•  Bright 750 Watt Lamp
•  Adjustable Flash Rate, Intenstiy Rate, and Flash Duration 
•  Colorful Strobing
•  Large coverage area
•  Thermostat Protection
•  Easy lamp Replacement
•  Link Up To 16 Units Together
•   Built-In Adjustable Hanging Yoke

Содержание ProTron LED

Страница 1: ... units may be linked together and controlled by single controller The units intensity flash rate and flash duration can be manually adjusted using the dip switches For remote control operation an optional remote control is available from Elation Professional Customer Support Elation Professional provides a customer sup port line to provide set up help and to answer any question should you encounte...

Страница 2: ...d Elation Profes sional service technician Use of a different type fuse from that which is recommended may cause fire or electric shock and will void the manufactures warranty To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Do not attempt to remove or break off the ground prong from the electrical co...

Страница 3: ... 4 address equals 8 Dipswitch 5 address equals 16 Dipswitch 6 address equals 32 Dipswitch 7 address equals 64 Dipswitch 8 address equals 128 Dipswitch 9 address equals 256 Dipswitch 10 Some units omit dipswitch 10 When a unit does include dipswitch 10 it is usually used for special functions such as sound activation Assigning DMX Address Each dipswitch has a preset value A spe cific DMX address is...

Страница 4: ...XLR to 5 Pin XLR Conversion Protron Color Operating Instructions Power Supply This unit is available only in 120v Before plugging your unit in be sure the source voltage in your area matches the required voltage for your Elation Protron Color General Operation This fixture is designed to operate as a stand alone unit or in a Master Slave configuration It can also operate via DMX controller The Pro...

Страница 5: ...minator on the last fixture 3 Assign your desired address to the unit and flip dipswitch 10 to the on postion 4 The Protron Color uses five DMX channels Use your DMX con troller to activate the various built in patterns See page 11 for a list of DMX traits 5 For help operating in DMX mode consult the manual included with your DMX controller NOTE If running in Master Slave address configuration whi...

Страница 6: ...please remember to always replace with the exact same type lamp 1 Be sure to follow the proper procedures when handling halogen lamps Never touch the new lamp with your bare fingers 2 Unscrew the two thumb screws located on the glass cover in the top corners of the unit 3 Loosen the small phillips screw located to the right of the reflector Halogen Lamp Warning This fixture is fitted with halogen ...

Страница 7: ...d this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the produc...

Страница 8: ...t be changed by the user Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Protron Color Specifications Elation Professional Elation World Headquarters 4295 Charter Street Los Angeles CA 90058 USA Tel 323 582 3322 Fax 323 582 3108 Web www elationlighting com E mail info elationlighting com Elation Profession...

Отзывы: