16
T O R Q U E S E T T I N G S F O R S C R E W S
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT,
TEST THE FIXTURE USING THE IP TESTER. CONTACT ELATION SERVICE
FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO
THE FIXTURE’S LENS WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Test Type
Minimum Pressure
Maximum Pressure
Steady/Hold Time
Vacuum Test
-1.88 psi
(-13.00 KPa)
-2.46 psi
(-17.00 KPa)
10 sec
Pressure Test
1.88 psi
(13.00 KPa)
2.46 psi
(17.00 KPa)
10 sec