1.

 

Lens  Assembly  -

  This  high  quality  lens  is  a  fully  focusing.  Focus  the  lens  by 

manually turning the lens in a clockwise or counter-clockwise direction until the 
desired effect is achieved. 

 

2.

 

DMX Input Jack –

 This 3-Pin XLR jack is used to receive an incoming DMX signal. 

 

3.

 

DMX  Output  Jack  – 

This 3-Pin XLR jack is used to send an outgoing DMX signal. 

For  best  results  this  jack  should  be  terminated  if  it  is  the  last  fixture  in  a  DMX 
daisy-chain (see termination on page 14). 

 

4.

 

Microphone  Sensitivity  Adjustment  Knob  –

 This knob is used to adjust the frequency 

sensitivity of the internal microphone when operating in “audio” mode. When the 
knob  is  turned  counter-clockwise  the  unit  is  less  sensitive  to  sound.  When  the 
knob is turned clockwise the unit is more sensitive sound.  

 

5.

 

Firmware  Connection  –

  This  connection  is  designed  to  be  used  solely  by  an 

authorized technician to upgrade the operating software and to test the fixture. 

 

6.

 

Internal  Cooling  Fan  – 

This  fixture  is  equipped  with  two  high-velocity  variable 

speed fans mounted in the base to aid in the cooling process. These fans are 
designed  to  vary  their  velocity  at  different  operating  temperatures.  When  the 
fixture reaches a predetermined internal operating temperature the fans function 
at high speeds. The higher speeds provide better cooling associated with higher 
operating temperatures during long use. When the fixture is operating at a lower 
temperature  the  fans  operate  at  low  speed.  Be  sure  to  keep  all  vents  clean, 
blocked  cooling  vents  can  shorten  lamp  life  and  reduce  the  fixtures  reliability. 
For more information on the fan functions see page 23, section 3.9.7. 

 

7.

 

Base  –

 The main base holds the majority of the electronics and logic boards. The 

base also provides a means to securely mount the fixture to the floor or ceiling. 

 

8.

 

Retaining  Arm  – 

These  arm  hold  the  head  in  place  and  provide  a  means  of  tilt 

movement.  These  arms  also  provide  a  conduit  for  all  the  electronics  traveling 
from the base to the head. 

 

9.

 

Lamp  Fuse  Holder  –

 This housing holds a 8A/250V GMA fuse. Never defeat this 

fuse,  this  fuse  is  designed  to  protect  the  lamp  in  the  event  of  severer  power 
fluctuations. In the event of fuse failure, always be sure to replace this fuse with 
an exact match unless otherwise instructed by an authorized Elation technician. 

10.

 

Electronics  Fuse  Holder  –

 This housing holds a 1A/250V GMA fuse. Never defeat 

this fuse, this fuse is designed to protect the electronics in the event of severer 
power  fluctuations.  In  the  event  of  fuse  failure,  always  be  sure  to  replace  this 

Содержание Power Spot 575IE II

Страница 1: ...II User Manual S oftware V ers ion 1 17 Rev is ed...

Страница 2: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 2 2 26 2008...

Страница 3: ...out 8 4 Mounting and Installation 11 a Mounting Positions 11 b Mounting Points 12 c Securing 12 5 Understanding DMX 14 a DMX Cable Requirements 14 b DMX Terminator 16 c 3 Pin to 5 Pin Conversion 16 d...

Страница 4: ...carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our custome...

Страница 5: ...rned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 DIS...

Страница 6: ...itial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from t...

Страница 7: ...performing any service related issues 4 Lamp Replacement Allow at least 30 minutes after disconnecting main power before you open the Power Spot 575IE II To prevent personal injury never touch the lam...

Страница 8: ...shock do not expose this fixture to rain or moisture 11 Do not attempt to operate this fixture if the power cord has become damaged or frayed Important Notice Damages resulting from the disregard of...

Страница 9: ...phone Sensitivity Adjustment Knob 5 Firmware Connection 6 Internal Cooling Fan 7 Base 8 Retaining Arm 9 Lamp Fuse Holder 10 Electronics Fuse Holder 11 Powercon Connector 12 Power Switch 13 Carrying Ha...

Страница 10: ...fferent operating temperatures When the fixture reaches a predetermined internal operating temperature the fans function at high speeds The higher speeds provide better cooling associated with higher...

Страница 11: ...always handle the fixture by the built in carrying handles Never lift or carry the fixture by the head or retaining arms as this could cause serious damage to the fixture and void your manufactures w...

Страница 12: ...mes the weight of the fixture Never use the carrying handles for secondary attachment Refer to regulations B GV C 1 formerly VB G 70 and DIN VDE 0711 217 for proper installation in E urope To ensure p...

Страница 13: ...g the wing nuts 90 90 b Be sure to always use two cam locks mounted to the bottom of unit to ensure safe truss mounting each two opposite threads max M10x20 4x M10x20mm 4x Camlock Secure the POWER SPO...

Страница 14: ...s are protected by two GMA 5x20mm external fuses Lamp 250V 8A Electronics 250V 1A The fuse requirements are clearly printed on the side of the fixture WA RNING A lways disconnect main power before cha...

Страница 15: ...ch the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end...

Страница 16: ...through serial linking The cable needed should be two conductor shielded cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DM...

Страница 17: ...r from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address...

Страница 18: ...al is being received the display will show A XXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash A XXX XXX representing the actual DMX addre...

Страница 19: ...functions AUDI ASLW Self running audio program slow AFST Self running audio program fast MSTR Master for the audio program SVPT Basic position for the audio program SIZE Size for the audio program NOR...

Страница 20: ...ed RESE will flash in the LED while fixture is in reset mode 2 Press the Mode button to access the main menu Toggle through the menu by pressing the Up and Down buttons until the display shows D001 Ta...

Страница 21: ...Confirm this setting in the SVPT menu by pressing the E nter button You can also set the size of the audio chaser in the SIZE menu You have the choice between NORM no basic position has to bee chosen...

Страница 22: ...Down buttons together for three seconds to reset this function LA 2 Lamp running time non destructible Total lamp hours logged by the unit 6 7 Invert Pan Movement RPAN This function allows you to inve...

Страница 23: ...e the Mode button to cancel at any time Function Value Remark PAN 000 255 Pan Position TILT 000 255 Tilt Position COLO 000 255 Color wheel GOB1 000 255 Gobo wheel 1 GROT 000 255 Gobo rotation GOB2 000...

Страница 24: ...u 6 9 4 DMX Input DMXI This function will display the DMX value of a channel in the LED as the fixture receives it Use the Up and Down buttons to select desired channel and press E nter to read its va...

Страница 25: ...85 C and 95 C Operating temperatures between 96 C and 104 C are considered critical Temperatures above 105 C will send the fixture into protect mode and automatically switch the lamp off the lamp will...

Страница 26: ...unction that requires calibration and press the E nter button to confirm the adjustment or the Mode button to cancel and return to the menu Use the Up and Down buttons to set the adjustment values and...

Страница 27: ...FF Lamp on via DMX DLOF ON OFF Display DISP D ON Cooling fan FANS HIGH REG LOOF LOHI Feedback FEED ON OFF 6 9 10 Feedback APC FEED The POWER SPOT 575IE is equipped with APC automatic position correcti...

Страница 28: ...d or even missed the fixture is overheating or there could be a failure on the igniter or ballast Switch off the power supply and solve the possible problem After the error IG E respectively LAER it i...

Страница 29: ...dual needs The Power Spot 575IE II uses 16 DMX channels See page 27 for detailed description of the DMX traits To control your fixture in DMX mode follow the set up procedures on pages 13 15 as well a...

Страница 30: ...ration Sound Active This function will allow you to link up to 16 fixtures together and operate without a controller The fixtures will be sound activated In Master Slave operation one fixture will act...

Страница 31: ...11 6 5 color 4 color 5 fast 18 19 12 13 7 3 color 5 Pink fast 20 21 14 15 8 0 color 5 color 6 fast 22 23 16 17 8 8 color 6 Orange fast 24 25 18 19 9 6 color 6 color 7 fast 26 27 1A 1 B 10 4 color 7 C...

Страница 32: ...81 50 color rotation slow fast CW min 1 4 turns h 130 191 82 BF 51 75 color rotation fast slow CCW max 2 9 turns sec 192 253 C0 F D 76 98 Audio color chaser slow each 4th sound impulse new color 254 F...

Страница 33: ...7 fast 24 27 18 1B 9 10 9 Gobo 8 fast 28 31 1C 1F 11 12 Gobo 9 fast 32 35 20 23 13 13 9 Gobo 10 fast 36 63 24 3F 14 24 9 Gobo 1 open fast 64 65 40 41 25 25 9 Gobo 1 open slow 66 67 42 43 26 26 9 Gobo...

Страница 34: ...6 Descend with Shutter random 144 159 90 9F 57 62 Ascend with Shutter audio 160 175 A0 A F 63 68 Descend with Shutter audio 176 191 B0 B F 69 75 Ascend with Shutter 192 207 C0 C F 76 81 Descend with S...

Страница 35: ...6 4 90 26 27 1A 1 B 10 4 4 180 28 29 1C 1 D 11 2 4 270 30 31 1E 1F 12 TILT size phase see also PAN 32 63 20 3F 13 25 PAN TILT size phase see also PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see...

Страница 36: ...last operation to cool down the fixture Don t touch the bulb of the lamp with bare fingers this can cause damages Before you put the POWER SPOT 575IE into operation close the casing otherwise your ret...

Страница 37: ...with your bare hands the oils from your skin may damage the lamp Always replace with the lamp with a lamp that meets the orginal lamp specification failure to do so may damage the unit and will void y...

Страница 38: ...instructions you may have to return the unit for servicing Continuing to use the unit may cause serious damage Fuse Replacement Locate and remove the unit s power cord from the main power supply Once...

Страница 39: ...ctive outside casing before attempting operation 1 1Installing Replacing Gobos 1 1 1 Always be sure to disconnect the main power supply before attempting any service 1 1 2 Remove the upper shell of th...

Страница 40: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 40 Special Notice If you use glass gobos the non vaporized side must be fitted towards the lamp direction...

Страница 41: ...nsiderations A lways disconnect main power before attempting any service related issues Allow ample time for the lamp to cool at least 20 minutes before performing any cleaning procedures Never attemp...

Страница 42: ...ners The lens should be changed at the first sign of ware usually in about 1 2 years lens will begin to look cloudy For lens replacement please contact E lation technical support Cleaning the Optical...

Страница 43: ...fixed exchangeable standard gobos plus open Gobo outside diameter 27 mm image size 23 mm All gobos as steel or glass Gobos exchangeable 9 spare Gobos Gobo thickness glass 1 1 mm steel 0 15 mm Shutter...

Страница 44: ...sionals shall have no liability whatsoever for loss of or damage to any such accessories or for the safe return thereof C This warranty is void if the serial number has been altered or removed if the...

Страница 45: ...warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer...

Страница 46: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 46 15 DIMENSIONS...

Страница 47: ...nLighting com Page 47 Laser Warning Labels When installing this fixture be sure that it is mounted in a manner that prevents the audience from directly into the laser beam Be sure the fixture is mount...

Страница 48: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 48...

Страница 49: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 49 Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax...

Страница 50: ...Power Spot 575IE II Elation Professionals Los Angeles Ca wwww ElationLighting com Page 50 www ElationLighting com info ElationLighitng com...

Отзывы: