background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                                                                           

26

                                                PLATINUM SEVEN™ User Manual

 

ELATION© PLATINUM SEVEN™ 

DMX Channel Values / Functions Version 1 - (40 DMX Channels) 

Supports Software Versions: 

 1.1.3 

Features are subject to change without any prior written notice. 

*Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings.

 

MODE / CHANNEL 

VALUE 

FUNCTION 

BASIC 

STAND 

EXTEND 

12 

19 

26 

  

COLOR MACROS 

0-7 

NO FUNCTION 

8-39 

From RED to YELLOW 

40-71 

From YELLOW to GREEN 

72-103 

From GREEN to CYAN 

104-135 

From CYAN to BLUE 

136-167 

From BLUE to MAGENA 

168-199 

From MAGENTA to RED 

200-231 

From RED to WHITE 

232-255 

Crossfading Colors from SLOW to FAST 

13 

20 

27 

  

COLOR PRESETS 

0-4 

NO FUNCTION 

5-9 

WHITE 2700K 

10-14 

WHITE 3200K 

15-19 

WHITE 4300K 

20-24 

WHITE 5600K 

25-29 

WHITE 6500K 

30-34 

WHITE 8000K 

35-39 

RED 

40-44 

GREEN 

45-49 

BLUE 

50-54 

NATURAL WHITE 

55-59 

FULL WHITE 

60-64 

YELLOW 

65-69 

MAGENTA 

70-74 

CYAN 

75-79 

SALMON 

80-84 

TURQUOISE 

85-89 

LIGHT GREEN 

90-94 

STEEL BLUE 

95-99 

ORANGE 

100-104 

STRAW 

105-109 

PALE LAVANDER 

110-114 

PINK 

115-119 

RED/WHITE 

120-124 

GREEN/RED 

125-129 

BLUE/RED 

130-134 

WHITE/RED 

135-139 

WHITE/PINK 

140-144 

WHITE/TURQUOISE 

145-149 

SMALL RED/WHITE 

150-154 

CRI=85 

155-159 

CRI=90 

160-164 

CRI=95 

165-255 

RESERVED 

Содержание PLATINUM SEVEN

Страница 1: ...PLATINUM SEVEN user manual E L A TI ON PLATINUM SEVEN user manual...

Страница 2: ...ries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient an...

Страница 3: ...O N T E N T S General Information 4 Warranty 6 Safety Instructions and Guidelines 7 Overview 9 Installation 10 System Menu 14 DMX Channel Functions And Values 24 LED Groups 29 Error Codes 30 Cleaning...

Страница 4: ...nance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If th...

Страница 5: ...chase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the ret...

Страница 6: ...r by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this war...

Страница 7: ...of this fixture and only the original rigging parts omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included wil...

Страница 8: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safety...

Страница 9: ...rray 2 Control Panel 3 LCD Menu Function Display 4 MODE ESC Button 5 LEFT Button 6 DOWN Button 7 ENTER Button 8 RIGHT Button 9 UP Button 10 Carrying Handle s 11 RJ45 Ethernet Input 12 RJ45 Ethernet Ou...

Страница 10: ...rotection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 1...

Страница 11: ...he included Omega Brackets using a M10 screw fitted through the center hole of the Omega Bracket The fixture provides a built in rigging point for a Safety Cable on the mounting bracket assembly as il...

Страница 12: ...y inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully o...

Страница 13: ...ION OF OTHER LIGHTING FIXTURES WILL VARY ART NET CONNECTION When connecting fixture to a network switch to control multiple devices a Gigabit Ethernet Switch that supports IGMP Internet Group Manageme...

Страница 14: ...u can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that f...

Страница 15: ...DMX ON OFF Address Via DMX No DMX Status Hold Close Shutter Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan De...

Страница 16: ...ode DMX Channel Modes Basic Mode Extended Mode User Mode A User Defined Channel Assignment User Mode B User Mode C Edit User Mode Edit User Mode A Max Channel XX PAN CH01 Edits User Defined Channel As...

Страница 17: ...F Address Via DMX No DMX Status Hold Close Shutter Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Selec...

Страница 18: ...01 SCxxx Program In Loop Program 10 Step 64 SCxxx Save and Exit Edit Scenes Scene 001 Scene 250 Pan Tilt Save and Automatically Return Fade Time Scene Time Manual Scenes Edit Input By Outside Stores...

Страница 19: ...s like adjusting the DMX starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX...

Страница 20: ...fine adjustments EFFECT ADJUST Calibration ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION This function allows small adjustments to be made to the Pan Tilt and Zoom movements to compensate f...

Страница 21: ...to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start an...

Страница 22: ...he same program as the master units U J KK ENTER to confirm U J KK MODE ESC in order to return to the main menu 4 Program Selection for Edit Program U D L ZEdit Program U J KK ENTER to confirm U lect...

Страница 23: ...a group of same model fixtures with varying usage times needs to be calibrated to match as much as possible Once a new White Balance preset is saved to the fixture the maximum dimmer intensity values...

Страница 24: ...3 3 TILT MOVEMENT 8 BIT 0 255 TILT Movement 4 4 4 TILT MOVEMENT 16 BIT 0 255 Fine Control of TILT Movement 5 5 RED ALL LEDs 0 255 Red 0 Black 255 100 6 RED FINE ALL LEDs 0 255 Red FINE Adjustment 6 7...

Страница 25: ...LED GROUP 1 0 255 Amber 0 Black 255 100 10 CYAN LED GROUP 1 0 255 Cyan 0 Black 255 100 11 VIOLET LED GROUP 1 0 255 Violet 0 Black 255 100 12 RED LED GROUP 2 0 255 Red 0 Black 255 100 13 GREEN LED GRO...

Страница 26: ...104 135 From CYAN to BLUE 136 167 From BLUE to MAGENA 168 199 From MAGENTA to RED 200 231 From RED to WHITE 232 255 Crossfading Colors from SLOW to FAST 13 20 27 COLOR PRESETS 0 4 NO FUNCTION 5 9 WHI...

Страница 27: ...utter OPEN LEDs ON 128 159 Pulse Effect In Sequences 160 191 Shutter OPEN LEDs ON 192 223 Random Strobe Effect SLOW to FAST 224 255 Shutter OPEN LEDs ON 16 23 30 DIMMER INTENSITY 0 255 Dimmer 0 to 100...

Страница 28: ...ITE BALANCE 0 189 NO FUNCTION 190 254 EDIT a New WHITE BALANCE Setting 255 SAVE New WHITE BALANCE Setting to Fixture s NOTE DMX Value 91 93 must first be selected on CH24 Basic CH31 Stand or CH40 Exte...

Страница 29: ...w w w e l a t i o n l i g h t i n g c o m 29 PLATINUM SEVEN User Manual L E D G R O U P S...

Страница 30: ...rror message 01Er 02Er and 05Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the moto...

Страница 31: ...during a reset function TILT The TILT movement is not located in the default position after the reset This message will appear after a fixture reset if the magnetic indexing circuit malfunctions sens...

Страница 32: ...fer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points...

Страница 33: ...UV 7 Colors Even and Smooth Color Mixing CONTROL CONNECTIONS 3 DMX Channel Modes 24 31 40 Adjustable Refresh Rate 900 1500 2500 4000 5000 10000 15000 20000 25000 Hz Adjustable Gamma Brightness 2 0 2 2...

Страница 34: ...514 AMBER 2 222 206 1 930 179 1 470 137 972 90 660 61 CYAN 6 316 587 5 680 528 4 162 387 2 625 244 1 776 165 U V 65 6 54 5 40 4 25 2 18 2 FULL ON 38 500 3 577 34 100 3 168 24 860 2 309 15 860 1 473 11...

Страница 35: ...without any prior written notice O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCPLAT7 Dual Road Case For PLATINUM SEVEN EWDMXSYSTEM Wire...

Страница 36: ......

Отзывы: