www.elationlighting.com
32
ELATION© PLATINUM 1200 WASH™
E R R O R C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
PAN
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a motor failure (defective motor or a
defective motor IC drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
TILT
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a motor failure (defective motor or defective
motor IC drive on main PCB). This error may also be displayed if the head was blocked
during a reset function.
ZOOM
The Zoom movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).