background image

Elation Professional  -  www.elationlighting.com  - Opti RGBA Instruction Manual Page 13

Elation Professional  -  www.elationlighting.com  - Opti RGBA Instruction Manual Page 14

Channel 1, 2, 3, & 4 will not work, when Channel 5 is being 

used.
When using Channel 7, Channel 6 will control the speed of the 

color changing.

 Opti RGBA    8 Channel Mode - DMX Values and Functions

  Channel     Value 

 

        Function

       

1                                                        RED

                       0 - 255                          0% - 100%           

       2                                                      GREEN

        

                                                                               

                 

                       0 - 255                          0% - 100%

       3                                                       BLUE

                       0 - 255                          0% - 100%

       4                                                     AMBER

                       0 - 255                          0% - 100%

       5              1 - 255                     COLOR MACROS 

                                           

PLEASE SEE 1 CHANNEL MODE

    

       6                                    STROBING/PROGRAM SPEED

                       0 - 15                             NOTHING

                     16 - 255                          STROBING  

                                                          SLOW - FAST

                       1 - 255        PROGRAM SPEED SLOW - FAST

       7                                                       MODE

                       0 - 127                               OFF

                   128 - 159                          AUTO MIX

                   160 - 191                    3 COLOR STROBE

                   192 - 223                    7 COLOR STROBE

                   224 - 255                       SOUND ACTIVE

       8                                              MASTER DIMMER                                                   

                       0 - 255                          0% - 100%

 Opti RGBA                                                             Cleaning

Due to fog residue, smoke, and dust cleaning the internal and exter-

nal optical lenses must be carried out periodically to optimize light 

output.  
1.   Use normal glass cleaner and a soft cloth to wipe down the 

  outside casing.

2.   Clean the external optics with glass cleaner and a soft cloth 

  every 20 days.

3.  Always be sure to dry all parts completely before plugging 

  the unit back in.

Cleaning frequency depends on the environment in which the fixture 

operates (i.e. smoke, fog residue, dust, dew). 

 Opti RGBA                                                Trouble Shooting

Listed below are a few common problems the user may encounter, 

with solutions.
Unit not responding to DMX:
1.  Check that the DMX cables are connected properly and are    

  wired correctly (pin 3 is “hot”; on some other DMX devices    

  pin 2 may be ‘hot’). Also, check that all cables are connected   

  to the right connectors; it does matter which way the inputs    

  and outputs are connected.
Unit does not respond to sound:
1.  Quiet or high pitched sounds will not activate the unit.

Содержание OPTI RGBA

Страница 1: ...owerful DMX intelligent 4 in 1 RGBA Red Green Blue Amber LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or...

Страница 2: ...inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has bee...

Страница 3: ...re to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either...

Страница 4: ...n Professional www elationlighting com Opti RGBA Instruction Manual Page 7 RGB Mode 1 Plug the fixture in and press the MODE button until 2 When rXXX is displayed you are in Red dimming mode Press the...

Страница 5: ...r Slave Operation This function will allows you to link units together to run in a Master Slave mode In Master Slave operation one unit will act as the controlling unit and the others will react to th...

Страница 6: ...55 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 Opti RGBA 5 Channel Mode DMX Values and Functions Elation Professional www elationlighting com Opti RGBA Instruction Manual...

Страница 7: ...residue smoke and dust cleaning the internal and exter nal optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside...

Страница 8: ...fessionals All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design a...

Отзывы: