Elation Lumina Strip Скачать руководство пользователя страница 5

5

5

POWER IN: 
100-240V~, 50/60Hz
FUSE:
T3.15A 250V 5x20mm
Power Consumption: 
90W max.

WARNING: / ATTENTION:

DRY LOCATIONS
EMPLACEMENTS SECS

NOT FOR RESIDENTIAL / HOUSEHOLD USE.
PAS POUR USAGE RESIDENTIEL / MENAGE.

RISK OF FIRE AND ELECTRIC SHOCK
RISQUE DE CHOC ELECTRIQUE ET INCENDIE

O

FOR SUPPLY CONNECTION S USE WITH WIR E RATED AT LEAST 60 C
POUR LES CONNEXIONS D'ALIMENTATION D E FIL D'UNE NOTATION 

O

MINIMALE DE 60 C

MINIMUM SAFE TY DISTANCE TO FLAMMABLE MATERIALS: 0.2m.
DISTANCE DE SECURITE AUX MATERIAUX COMBUSTIBLES: 0.2m.

O

MAXIMUM OPERATING TEMPERATURE OF ENCLOSURE SURFACE IS 60 C

O

TEMPER ATURE DE FONCTIONNEMENT 

DE SURFACE ENCEINTE EST A 60 C

FUSE

POWER

MODE

MENU

RDM/DMX

POWER

UP

DOWN

Made in China

RDM/DMX OUT

POWER THRU

(15A Max.)

Earth

Neutral

Live

RDM/DMX IN

POWER IN

(15A Max.)

Earth

Neutral

Live

Safety chain/cord 
attachment point

Safety chain/cord 
attachment point

1=Ground
2=Data-
3=Data+
4,5=NC

1=Ground
2=Data-
3=Data+
4,5=NC

MODE

MENU

DISPLAY

DMX

Program

Address

Channel

No DMX

Glide

Program

Speed

Master

Lamp Mode

Fade Time

001 -- 512

07 / 08 / 10 / 11 / 16

OFF / Hold / Program

OFF / ON

Full / 01-- 16 / Auto

01 -- 100

00 -- 100

Tungsten / LED

00 -- 100

o

40 C 

0.2m 

Lumina Strip

FOR SAFETY INSTRUCTION AND MOUNTING OPTIONS REFER TO USER MANUAL

4

1

Layout Overview

1. Lamp:

 

Totally 10 LEDs* Warm White, 7W

1. LCD Display

   This multi-function display will detail all DMX Address, Chase , Program, Speed activity that pertains to the

   current operation mode of the unit.

2. Mode button

   This button will call up the unit operation mode between DMX and Chase mode.

3. Menu button

   This button will active the different functions in Receive and Chase modes.

Front Panel Overview

Rear Panel Overview

6

8

2 3 4 5

7

9

10

1

11

Note: In the Chase mode, Menu key is used to only activate Chase Dimmer, Chase Program, Chase Speed, 

Fade Time and Lamp Mode. While in the " Receive " mode, only used to only select DMX Address, Channel. 

4. UP button

    This button will increase the displayed value in the LED display.

5. Down Key

    This button will decrease the displayed value in the LED display.

6. DMX Out 

    This connector sends your DMX signal through to the next unit. 

7. DMX In

    This connector accepts your DMX input signal.

8. Power Input: 

    AC100-240V~50/60Hz, Max15A. The supply power is input into your unit via this connector. Be sure to 

   always connect to proper voltage.

9. Power Thru:

    AC100-240V~50/60Hz, Max15A. This connector sends the supply power to the next unit.

10. Fuse:

      F3.15A 250V 5*20mm. These fuses prevent you from overloading damaging your unit. Be sure to always 

      replace with the exact same type fuse.

11. Power Switch:

      Turn on/off the power supply.

Lumina Strip 

Содержание Lumina Strip

Страница 1: ...Lumina Strip USER MANUAL Version 1 2 24 004 3557 00 90040 3402 ...

Страница 2: ...This device is not suitable for direct mounting on normally flammable surfaces To keep a minimum 0 2m safety distance to any flammable materials DO NOT make any inflammable liquids water or metal objects enter the unit This unit contains no user serviceable parts inside This unit contains dangerous voltages always remove the power plug from the wall socket before any service operation and when not...

Страница 3: ... four screws are secured firmly if not please secure them with the screwdriver loose 4 screws for lamp replacement The unit has also been designed to hold up as user s desire So you can fix the unit on the holder by the wing screw They are placed in the accessory bag included The following installation diagrams are for user reference INSTALLATION Method 1 Method 2 Note Once this unit is for hangin...

Страница 4: ...zed service technician SYSTEM CONNECTION Maximum amount of this units that may be connected is 16pcs AC100 120V or 32pcs 220 240V One universe DMX can drive up to 32 pcs of Lumina Strip please add DMX booster if Lumina Strip are connected together in line over 32 pcs or data cable over 100M The connections may be illuminated as following 3pin Power Cable 5pin DMX Cable DMX IN 1 2 3 32 POWER IN DMX...

Страница 5: ...ION AND MOUNTING OPTIONS REFER TO USER MANUAL 4 1 Layout Overview 1 Lamp Totally 10 LEDs Warm White 7W 1 LCD Display This multi function display will detail all DMX Address Chase Program Speed activity that pertains to the current operation mode of the unit 2 Mode button This button will call up the unit operation mode between DMX and Chase mode 3 Menu button This button will active the different ...

Страница 6: ...5 Lumina Strip LCD Display Menu System MODE MENU RDM DMX POWER UP DOWN LCD Display Mode Key Menu Key Up Key Power indicator RDM DMX indicator Down Key Lumina Matrix LED Menu Tree ...

Страница 7: ...annel DMX dimmer and DMX address Tap Mode button to switch the operation mode between DMX and Program DMX Mode Mode Parameter Parameter Value Function DMX Program Address Channel No DMX Glide Program Speed Master Lamp Mode Fade Time 001 512 07 08 10 11 16 OFF Hold Program OFF ON Full 01 16 AUTO 01 100 00 100 Tungsten LED 00 100 To set the initial DMX receiving address To set the DMX Control Mode T...

Страница 8: ...t to Unit Setting TV dr 3 dr 4 Programs Master Dimmer Master Dim Fine Program Speed Program Fade Dim Mode Dim Mode 8 Bit 7 Channel Configuration 8 Channel Configuration 10 Channel Configuration 0 255 0 255 bright bright bright bright Fast More 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Standard dr 1 Stage dr 2 TV dr 3 Architectural dr 4 Theatre dr 5 D...

Страница 9: ...chitectural dr 4 Architectural dr 4 Architectural dr 4 Theatre dr 5 Theatre dr 5 Theatre dr 5 Default to Unit Setting Default to Unit Setting Default to Unit Setting 0 20 0 20 0 20 21 40 21 40 21 40 41 60 41 60 41 60 61 80 61 80 61 80 81 100 81 100 81 100 101 255 101 255 101 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Master Dim Dim Mode 0 255 0 255 0 255 0 255 0 255 LED 1 10 0...

Страница 10: ...tting 0 20 0 20 0 20 21 40 21 40 21 40 41 60 41 60 41 60 61 80 61 80 61 80 81 100 81 100 81 100 101 255 101 255 101 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Master Dim Fine Dim Mode 16 bit 0 255 0 255 0 255 Dim Mode 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255...

Страница 11: ...DIM MODES Lumina Strip 10 ...

Страница 12: ...D will display LampMode Tungdten user can press UP or DOWN button to switch to LampMode LED menu Press MENU button and select Fade Time menu the LCD will display FadeTime followed by three digits user can press UP or DOWN button set the desired Fade time value from 000 to 100 Selecting any program of Program01 16 will activate the selected program while selecting Auto will automatically play the b...

Страница 13: ...Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with Lumina Strip Table 1 Lumina Strip RDM Parameter IDs Lumina Strip LED Light Elation lighting 12 Lumina Strip Lumina Strip ...

Страница 14: ...and DOWN buttons to change the DMX Address Value Note There is no DMX input in the master unit of the connection Address 001 Channel 01 MODE MENU UP DOWN MODE MENU UP DOWN Press MENU button and select Channel Mode The Channel Mode is indicated by Channel followed by two digits 07 08 10 11 16 You can tap the UP and DOWN buttons to change the setting from 07 08 10 11 or 16 which you wish to run Chan...

Страница 15: ...Table 1 Lumina Strip RDM Parameter IDs Lumina Strip 14 ...

Страница 16: ...able B 2 ANSI E1 20 2010 Status Message ID Value Data Value 1 Data Value 2 Status ID Description 8100H 00H 00H ALL OK Manufacturer Specific PIDs Manufacturer Defind PIDs range is 0x8000 0xffdf See Table A 3 ANSI E1 20 2010 Get Allowed SET Allowed RDM Parameter Id s TYPE UNIT PREFIX MIN MAX DEFAULT DESCRIPTION chase program chase speed chase dimmer lamp mode fade time percent 8A08H 8A09H 8A01H 8A42...

Страница 17: ...m_Tool exe software the tool will search RDM devices automatically for the first time user may also search devices via ArtTod Control command When the software searched a RDM device the RDM UID will be listed in the RDM UID Lists Select the listing RDM UID then press Update Selected Device command to upload the desired updating program press open command to start updating After finishing updating ...

Страница 18: ...TENTION DRY LOCATIONS EMPLACEMENTS SECS NOT FOR RESIDENTIAL HOUSEHOLD USE PAS POUR USAGE RESIDENTIEL MENAGE RISK OF FIRE AND ELECTRIC SHOCK RISQUE DE CHOC ELECTRIQUE ET INCENDIE O FOR SUPPLY CONNECTIONS USE WITH WIRE RA TED AT LEAST 60 C POUR LES CONNEXIONS D ALIMENT ATION DE FIL D UNE NOTATION O MINIMALE DE 60 C MINIMUM SAFETY DIST ANCE TO FLAMMABLE MA TERIALS 0 2m DISTANCE DE SECURITE AUX MATERI...

Отзывы: