![Elation FS-150SCI Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/elation/fs-150sci/fs-150sci_user-instructions_2376171002.webp)
Power Supply:
Before plugging your unit in, be sure the source volt-
age in your area matches the required voltage for your Elation
®
FS-
150SCI.™ The Elation
®
FS-150SCI
™
is available in a 115v and 230v
version. Because line voltage may vary from venue to venue, be sure to
plug your unit into a matching wall outlet before attempting to operate.
Data Cable (DMX Cable) Requirements (For DMX Operation
Only and Master-Slave):
The FS-150SCI can be controlled via
DMX-512 protocol. The Elation
®
FS-150SCI™ is a three channel DMX
unit. The DMX address is set on the front panel of the FS-150SCI.
Your unit and your DMX controller require a stan-
dard 3-pin XLR connector for data input and data
output (Figure 1). If you are making your own
cables, be sure to use standard two conductor
shielded cable (This cable may be purchased at
almost all pro sound and lighting stores). Your
cables should be made with a male and female
XLR connector on either end of the cable. Also
remember that DMX cable must be daisy chained
and can not be split.
Notice:
Be sure to follow figure three when making your own cables.
Do not use the ground lug on the XLR connector. Do not connect the
cable’s shield conductor to the ground lug or allow the shield conductor
to come in contact with the XLR’s outer casing. Grounding the shield
could cause a short circuit and erratic behavior.
©
Elation Professionals
®
- www.elationlighting.com - FS-150SCI™ Instruction Manual Page 3
©
Elation Professionals
®
- www.elationlighting.com - FS-150SCI™ Instruction Manual Page 4
Figure 1
Figure 2
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT
OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT
OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT
OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 3
FS-150SCI™ Set Up
1 Ground
1 Ground
XLR Male Socket
XLR Pin Configuration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Shield
SAFETY PRECAUTIONS:
• Do not spill water or other liquids in to or on to your unit.
• Be sure that the local power outlet match that of the required voltage
for your unit.
• Do not attempt to operate this unit if the power cord has been frayed
or broken. Please route your power cord out of the way of foot traf-
fic.
• Do not attempt to remove or break off the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and fire in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the top cover under any conditions. There are no
user serviceable parts inside.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged in any
way.
• Never operate this unit when it’s cover is removed.
• To reduce the risk of electrical shock or fire, do not expose this unit
rain or moisture
• This unit is intended for indoor use only, use of this product outdoors
voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
FEATURES:
• Seven vibrant colors plus white.
• Long life (9000 hours) SC-150 discharge lamp.
• Variable speed shutter.
• Micro-stepping motors for smooth color transitions.
• Built in controller - Run up to 16 heads with the built-in controller.
• Master/Slave configuration
• DMX-512 protocol capable
• Full Focusing.
• Fully automated IRIS.
• Fan cooled.
• Uses 3 DMX Channels.
FS-150SCI™ Introduction