Elation Eled Light Скачать руководство пользователя страница 3

Elation Professional  -  www.elationlighting.com  - ELED Fresnel Instruction Manual Page 5

ELED Fresnel                                                             Set Up

Elation Professional  -  www.elationlighting.com  - ELED Fresnel Instruction Manual Page 6

ELED Fresnel 

 

                                           Set Up

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your Elation

®

 ELED 

Fresnel™.  The  ELED  Fresnel™  voltage  is  between  100v  ~  240v.  Be 

sure to only use the included I.E.C. power cable supplied with the unit, 
this cable matches the current requirements of the unit.

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro

-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav

-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter

-

minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compliant. 

To  ensure  proper  DMX  data  transmission,  when  using  several  DMX 

fixtures try to use the shortest cable path possible. The order in which 
fixtures are connected in a DMX line does not influence the DMX ad

-

dressing. For example; a fixture assigned a DMX address of 1 may be 

placed anywhere in a DMX line, at the beginning, at the end, or any-

where in the middle. When a fixture is assigned a DMX address of 1, 
the DMX controller knows to send DATA assigned to address 1 to that 

unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The ELED Fresnel™ can be controlled via DMX-512 protocol. The ELED 
Fresnel™ can be a two, three, four, six, seven or 11 channel DMX unit. 

The DMX address is set on the back panel of the ELED Fresnel™. Your 

unit and your DMX controller require a approved DMX-512 110 Ohm 
Data cable for data input and data output (Figure 1). We recommend 
Accu-Cable DMX cables. If you are making your 
own  cables,  be  sure  to  use  standard  110-120 

Ohm  shielded  cable  (This  cable  may  be  pur-
chased  at  almost  all  professional  sound  and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end 

of the cable. Also remember that DMX cable must 

be daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con

-

nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Отзывы: