INTRODUCTION

 

Congratulations, you have just purchased one of the most innovative and 
reliable  IP65 rated lighting fixtures on the market today! This fixture  has been 
designed to perform reliably for years when the guidelines in this booklet are 
followed. Please read and understand the instructions in this manual carefully 
and thoroughly before attempting to operate this unit. These instructions contain 
important information regarding safety during use and maintenance.   

IP65 RATED 

An IP rated lighting fixture is one, which is commonly installed in outdoor 

environments and has been designed with an enclosure that effectively protects 

the ingress (entry) of external foreign objects such as dust and water. The 

International Protection (IP) 

rating system is commonly expressed as 

"IP"

 (Ingress 

Protection) followed by two numbers (i.e. IP65) where the numbers define the 

degree of protection. The first digit (Foreign  Bodies Protection) indicates the 

extent of protection against particles entering the fixture and the second digit 

(Water Protection) indicates the extent of protection against water entering the 

fixture. An IP65 rated lighting fixture is one, which has been designed and tested 

to protect against the ingress of dust (6) and high-pressure water jets from any 

direction (5). 

 

M A R I N E / C O A S T A L   E N V I R O N M E N T   I N S T A L L A T I O N S !  

Please note although this fixture is IP rated, the fixture is 

NOT

 suitable for marine 

and/or coastal environment installations. Installing this fixture in a marine and/or 

coastal environment may cause corrosion and/or excessive wear to the interior 

and/or exterior components of the fixture.  Damages and/or performance 

issues resulting from installation in a marine and/or coastal environment will void 

the manufactures warranty and will 

NOT

  be subject to any warranty claims 

and/or repairs. 

 

ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH  A 
NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT  MOST ELECTRICAL 
SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION. 

O P T I O N A L   C O R R O S I O N - R E S I S T A N T   C O A T I N G  

Optional Corrosion-Resistant Coatings may be available for this fixture. 

Please consult your 

Elation Professional

 sales representative for details. 

 

Содержание DTW BLINDER 350 IP

Страница 1: ...DTW BLINDER 350 IP user manual E L A TI ON DTW BLINDER 350 IP user manual...

Страница 2: ...OFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss asso...

Страница 3: ...IP User Manual C O N T E N T S General Information 4 Warranty 7 Safety Instructions and Guidelines 8 Overview 10 Installation 11 System Menu 15 DMX Channel Functions And Values 18 Cleaning and Mainten...

Страница 4: ...nst particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been desi...

Страница 5: ...mer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 powerCON TRUE1 Cable 2 Removable 25 Narrow Beam Fresnel Le...

Страница 6: ...n a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on...

Страница 7: ...ser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this w...

Страница 8: ...omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will void the original manufactures warranty and incre...

Страница 9: ...a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safet...

Страница 10: ...w w w e l a t i o n l i g h t i n g c o m 10 DTW BLINDER 350 IP User Manual O V E R V I E W SAFETY CABLE RIGGING POINTS...

Страница 11: ...ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized person...

Страница 12: ...egrated into the back of the fixture RIGGING Overhead rigging requires extensive experience including amongst others calculating working load limits installation material being used and periodic safet...

Страница 13: ...horizontal at 9 and 3 o clock See image below left 2 Insert lens into COB module See image below right 3 While applying gentle pressure against the lens slowly turn the lens counter clockwise a turn u...

Страница 14: ...NG Max number of DTW BLINDER 350 IP units power linked together 3 units 120V 6 units 240V NOTE USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO DTW BLINDER 350 IP POWER CONSUMPTION OF OTHER LIGHTING F...

Страница 15: ...button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button LCD CONTROL PANEL LOCKOUT FEATURE When the AUTO LOCK m...

Страница 16: ...lue WW 000 255 Set Manual Warm White Value Amber 000 255 Set Manual Amber Value FADING SPEED 00 99 Set Fading Program Speed FLASH 000 255 Set Fading Program Flash Rate DIMMER Standard Stage TV Archite...

Страница 17: ...w w w e l a t i o n l i g h t i n g c o m 17 DTW BLINDER 350 IP User Manual DIMMER Select desired DIMMER MODE Standard Stage TV Architectural Theatre...

Страница 18: ...k 255 100 2 2 0 255 AMBER PIXEL 1 Warm White 0 Black 255 100 3 3 0 255 WARM WHITE PIXEL 2 Cool White 0 Black 255 100 4 4 0 255 AMBER PIXEL 2 Warm White 0 Black 255 100 1 5 3 5 0 255 DIM TO WARM All PI...

Страница 19: ...refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following point...

Страница 20: ...m Channel Control 1 800K 3 200K Electric Strobe and Variable Dimming Curves Modes CONTROL CONNECTIONS 9 DMX Channel Modes 9 Total Channels 4 Touch Button Control Panel and LCD Menu Display RDM Remote...

Страница 21: ...21 7 3 lux fc lux fc lux fc WW LEDs 3 100K 3 447 320 1 992 185 1 321 123 AMBER LEDS 1 400K 352 33 213 20 143 13 FULL ON 2 940K 6 269 582 3 417 317 2 424 225 78 Beam Diameter No Fresnel Lens 3 m 9 8 f...

Страница 22: ...l i g h t i n g c o m 22 DTW BLINDER 350 IP User Manual DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any p...

Страница 23: ...3 DTW BLINDER 350 IP User Manual O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Clamp 8050000053 Omega Bracket 107mm NEU088 3 ft 1m PowerCON TRUE1 Power Lin...

Страница 24: ......

Отзывы: