S Y S T E M   M E N U  

The  fixture  comes with an  easy to navigate system menu. The control panel (see 
image below) located on the front the fixture provides access to the main system 
menu and is where all necessary system adjustments are made to the fixture. During 
normal operation, pressing 

MODE

 button once will access the fixture’s main menu. 

Once in the main menu you can navigate through the different functions and 
access the sub-menus with the 

UP 

and 

DOWN 

buttons. Once you reach a field that 

requires adjusting, press the 

ENTER

 button to activate that field and use the 

UP

 and 

DOWN

 buttons to adjust the field. Pressing the 

ENTER 

button once more will confirm 

your setting. You may exit  the main menu at any time without making any 
adjustments by pressing the 

MODE/ESC

 button. 

LCD CONTROL PANEL LOCKOUT FEATURE 

When the 

AUTO LOCK

  menu is set to 

ON 

(default setting); the LCD control panel 

display will turn OFF and become LOCKED after non-use. To UNLOCK, press the 

ENTER

  button followed by pressing and holding the 

MODE

  button until the LCD 

control panel display is UNLOCKED. 

 

When the 

AUTO LOCK

 menu is set to 

ON1

 and is LOCKED, follow these steps to UNLOCK: 

 

1.

 

When locked, the display will show: 

LOCKED*****

 

2.

 

Press 

UP

, then the display will change to: 

LOCKED****

 (one * disappears) 

3.

 

Press 

DOWN

, then the display will change to: 

LOCKED***

 (two * disappear) 

4.

 

Press 

UP

, then the display will change to: 

LOCKED**

 (three * disappear) 

5.

 

Press 

DOWN

, then the display will change to: 

LOCKED*

 (4 * disappear) 

6.

 

Press 

ENTER

, then the display will change to 

LOCKED

 and then become unlocked. 

 

Содержание DTW BLINDER 350 IP

Страница 1: ...DTW BLINDER 350 IP user manual E L A TI ON DTW BLINDER 350 IP user manual...

Страница 2: ...OFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss asso...

Страница 3: ...IP User Manual C O N T E N T S General Information 4 Warranty 7 Safety Instructions and Guidelines 8 Overview 10 Installation 11 System Menu 15 DMX Channel Functions And Values 18 Cleaning and Mainten...

Страница 4: ...nst particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been desi...

Страница 5: ...mer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 powerCON TRUE1 Cable 2 Removable 25 Narrow Beam Fresnel Le...

Страница 6: ...n a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on...

Страница 7: ...ser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this w...

Страница 8: ...omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will void the original manufactures warranty and incre...

Страница 9: ...a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safet...

Страница 10: ...w w w e l a t i o n l i g h t i n g c o m 10 DTW BLINDER 350 IP User Manual O V E R V I E W SAFETY CABLE RIGGING POINTS...

Страница 11: ...ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized person...

Страница 12: ...egrated into the back of the fixture RIGGING Overhead rigging requires extensive experience including amongst others calculating working load limits installation material being used and periodic safet...

Страница 13: ...horizontal at 9 and 3 o clock See image below left 2 Insert lens into COB module See image below right 3 While applying gentle pressure against the lens slowly turn the lens counter clockwise a turn u...

Страница 14: ...NG Max number of DTW BLINDER 350 IP units power linked together 3 units 120V 6 units 240V NOTE USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO DTW BLINDER 350 IP POWER CONSUMPTION OF OTHER LIGHTING F...

Страница 15: ...button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button LCD CONTROL PANEL LOCKOUT FEATURE When the AUTO LOCK m...

Страница 16: ...lue WW 000 255 Set Manual Warm White Value Amber 000 255 Set Manual Amber Value FADING SPEED 00 99 Set Fading Program Speed FLASH 000 255 Set Fading Program Flash Rate DIMMER Standard Stage TV Archite...

Страница 17: ...w w w e l a t i o n l i g h t i n g c o m 17 DTW BLINDER 350 IP User Manual DIMMER Select desired DIMMER MODE Standard Stage TV Architectural Theatre...

Страница 18: ...k 255 100 2 2 0 255 AMBER PIXEL 1 Warm White 0 Black 255 100 3 3 0 255 WARM WHITE PIXEL 2 Cool White 0 Black 255 100 4 4 0 255 AMBER PIXEL 2 Warm White 0 Black 255 100 1 5 3 5 0 255 DIM TO WARM All PI...

Страница 19: ...refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following point...

Страница 20: ...m Channel Control 1 800K 3 200K Electric Strobe and Variable Dimming Curves Modes CONTROL CONNECTIONS 9 DMX Channel Modes 9 Total Channels 4 Touch Button Control Panel and LCD Menu Display RDM Remote...

Страница 21: ...21 7 3 lux fc lux fc lux fc WW LEDs 3 100K 3 447 320 1 992 185 1 321 123 AMBER LEDS 1 400K 352 33 213 20 143 13 FULL ON 2 940K 6 269 582 3 417 317 2 424 225 78 Beam Diameter No Fresnel Lens 3 m 9 8 f...

Страница 22: ...l i g h t i n g c o m 22 DTW BLINDER 350 IP User Manual DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any p...

Страница 23: ...3 DTW BLINDER 350 IP User Manual O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Clamp 8050000053 Omega Bracket 107mm NEU088 3 ft 1m PowerCON TRUE1 Power Lin...

Страница 24: ......

Отзывы: