![Elation Design Spot 250 Pro Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/elation/design-spot-250-pro/design-spot-250-pro_user-manual_2376109046.webp)
Design Spot 250 Pro™
©Elation Professional® 46 Design Spot 250 Pro™
defective motor IC drive on the main PCB).
05Er -
Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er -
Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er -
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.
This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
08Er -
Fix Gobo-wheel error
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive
circuit on the main PCB). The fix gobo wheel is not located in the default position after the
reset.
09Er -
Prism-wheel error
This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Prism wheel is not located in the default position after
the reset.
10Er
- Focus-error
This message will appear after the reset of the fixture and if the magnetic indexing circuit
Содержание Design Spot 250 Pro
Страница 2: ...Design Spot 250 Pro Elation Professional 2 Design Spot 250 Pro...
Страница 51: ...Design Spot 250 Pro Elation Professional 51 Design Spot 250 Pro 16 PHOTOMETRIC DATA...
Страница 52: ...Design Spot 250 Pro Elation Professional 52 Design Spot 250 Pro 17 GOBOS...
Страница 53: ...Design Spot 250 Pro Elation Professional 53 Design Spot 250 Pro 18 DIMENSIONAL DRAWINGS...
Страница 54: ...Design Spot 250 Pro Elation Professional 54 Design Spot 250 Pro 19 CIRCUIT SCHEMATIC...