background image

 

 

If the device has been exposed to temperature changes due to environmental changes, do not switch 
it on immediately. The arising condensation could damage the device. Leave the device switched off 
until it has reached room temperature. 
 
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by 
the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

 

 

This device falls under protection-class I. Therefore it is essential that the device be earthed. 
The electric connection must carry out by qualified person. 
Make sure that the available voltage is not higher than stated at the end of this manual. 
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 
replacement of the cable must be done by an authorized dealer. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 
During initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective, it should decrease gradually. 
 

Never touch the device during operation! 

The housing may heat up 

CAUTION!

 

Please be aware that damages caused by manual modifications to the device are not subject to 
warranty. Keep away from children and non-professionals. 
 

GENERAL GUIDELINES 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc. 
This fixture is only allowed to be operated with the max alternating current which stated in the 
technical specifications in the last page of this manual, the device was designed for indoor use only. 
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure 
that the device will serve you for a long time without defects. Do not shake the device. 
Avoid brute force when installing or operating the device. 
 
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, 
moisture or dust. The minimum distance between light-output from the projector   
 
Always fix the fixture with an appropriate safety cable if you use the clamp to hang up the fixture. 
When fixing the device on a raised-from-the- ground support, be sure to use no less than screws and 
nuts of M10 x 25 mm and insert them in the pre-arranged screw holes in the base of the fixture. 
If you use the quick lock cam in hanging up the fixture, please make sure the 4 quick lock fasteners 
turned in the quick lock holes correctly. 
 
Operate the device only after having familiarized with its functions. Do not permit operation by 
persons not qualified for operating the device. Most damages are the result of unprofessional 

                                                                                                    - 

 -                               XM080-V1.0 NR       

                             

Содержание DESIGN PROMO 360

Страница 1: ...DESIGN PROMO 360 USER MANUAL...

Страница 2: ...there be any consult your dealer and don t install this device Features 16 bit resolution Movement 540 630 optional For smooth and precise resolution Can rotate continuously While Channel 4 on DMX va...

Страница 3: ...by manual modifications to the device are not subject to warranty Keep away from children and non professionals GENERAL GUIDELINES This device is a lighting effect for professional use on stages in di...

Страница 4: ...ate safety cable Never stand directly below the device when mounting removing or servicing the fixture The operator has to make sure the safety relating and machine technical installations are approve...

Страница 5: ...stall the second Omega holder Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safet...

Страница 6: ...the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You...

Страница 7: ...address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the device the controller is switched off or defective if the cable or...

Страница 8: ...atic Run as Master ALON SO A Sound controlled Run in Stand Alone RUN SOUN MAST SO M Sound controlled Run as Master VALU D XX D 00 DXXX Display the DMX 512 value of each channel RDIS ON OFF Reverse dis...

Страница 9: ...r pressing MODE ESC to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 P...

Страница 10: ...desired channel If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm or Press MODE ESC to return to the main menu Reverse display With this functio...

Страница 11: ...the main menu Pan degree select With this function you can select pan angle 6300 or 5400 1 Select DEGR by pressing UP or DOWN button 2 Press ENTER the display shows 630 or 540 3 Press UP or DOWN butt...

Страница 12: ...of the device All settings will be set back to the default values shaded Any edited scenes will be lost 1 Select LODA by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP...

Страница 13: ...or Press MODE ESC to return to the main menu Editing the channels of the individual scenes With this function you can edit the program to be called up in Run a Editing via the Control Board 1 Select S...

Страница 14: ...DOWN button 5 Press ENTER the display shows OFF 6 Press UP or DOWN button the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time...

Страница 15: ...be correct by a technician The errors in question will remain flashing in the display as a reminder of internal errors 01 Er pan movement wheel error The pan movement wheel is not located in the defa...

Страница 16: ...C 60Hz 230VAC 60Hz 240VAC 60Hz Power consumption max 45W Motors 1 micro motors PCB model MH 250 PT 05D PCB fuse F1 4L F2 5L 2PCS Packing dimensions 45x31x49cm Net weight 10 5 KGS Gross weight 14KGS Re...