number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit.

1. Access the main menu.

2. Tap the UP button until “EDIT” is displayed, press ENTER.

3. Tap the UP button until “RUN” is displayed, press ENTER.

4.  “AUTO”  is  displayed.  If  you  press  the  UP  button  it  will  show  “SOUN”. Select

which one you want to activate, and press ENTER.

5.  Press  UP,  to  select  “ALON”  or  “NAST”.  Which  mean  stand  alone,  and

master/slave mode.

6.  Select a mode, and press ENTER to confirm.

7.  Press MODE/ESC to return to the main menu.

Содержание Design Par 575H

Страница 1: ...Rev 3 09 2007 Design Par 575H Elation Professional 4295 Charter Street Los Angeles Ca 90058 www elationlighting com...

Страница 2: ...llation 13 a Lamp optimization 14 1 Mounting and Installation 16 a Mounting Positions 17 a Mounting Points 18 a Securing 19 1 Understanding DMX 20 a DMX Connections 20 a DMX Terminator 21 a 3 Pin to 5...

Страница 3: ...unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for furt...

Страница 4: ...ed on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 HALOGEN LAMP WARNING This fixture is fitt...

Страница 5: ...ltage requirements of the unit Be sure the power cord is never crimped or damaged If the power cord is damaged replace it immediately with a new one of similar power rating Always disconnect from main...

Страница 6: ...low at least 30 minutes after disconnecting main power before you open the DESIGN PAR 575H To prevent personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never look dir...

Страница 7: ...o not attempt to operate this fixture if the power cord has become damaged or frayed Important Notice Damages resulting from the disregard of safety and general user instructions found in this user ma...

Страница 8: ...MX addressing from any DMX console Auto test for all functions Automatic Pan Tilt Correction Glass Dichroic Reflector for Even Lamp Output Anti Reflective Coated Lenses Gel frame holder included Uses...

Страница 9: ...be at least 5 meter about 1 5ft Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always be to use mounting hardware no less than M10 x...

Страница 10: ...Par 575H Elation Professional 10 Design Par 575H 5 FIXTURE OVERVIEW 1 HEAD ASSEMBLY This assembly holds the lamp gel holder lens and reflector 2 LAMP SOCKET ASSEMBLY COVER This cover retains the lamp...

Страница 11: ...u system 7 DOWN BUTTON This button is used to scroll backwards when navigating through the fixture s menu system 8 ENTER BUTTON This button is used to select and confirm a menu function 9 DATA PORT Th...

Страница 12: ...troller 15 OMEGA CLAMP SOCKET This fixture uses a cam lock clamp system that allows a quick and efficient means to secure a clamp to the unit To attach a clamp to the unit attach a clamp that is rated...

Страница 13: ...is hot During the installation of halogen lamps do not touch the glass portion of the bulb bare handed Always use a cloth to handle the lamps during insertion and removal Do not install lamps with a h...

Страница 14: ...tput and reduce intensity The minimum deviation amount is 1 0mm Running the fixture within a lower deviation can cause damage to the lamp and or lens The Design Par 575H lamp holder is aligned at the...

Страница 15: ...nly distributed 4 If the light is brighter around the edge than it is in the center or if light output is low the lamp is too far back in the reflector Push the lamp out by turning each of the adjustm...

Страница 16: ...e Before taking into operation for the first time the installation has to be approved by an expert When installing the device make sure there is no highly inflammable material within a distance of min...

Страница 17: ...rking load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt t...

Страница 18: ...at integrates the hanging yoke as well as the safety cable rigging point in one unit see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamp to th...

Страница 19: ...choose for your DESIGN PAR 575H always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above B...

Страница 20: ...hielded digital cable rated at a 120 ohms this cable can be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female 3 pin XLR connector on eith...

Страница 21: ...DMX 512 connection with DMX terminator You should always use a terminator on the last fixture to avoid erratic behavior A terminator is a 90 120 ohm 1 4 watt resistor that is connected between pins 2...

Страница 22: ...e Be advised that setting all you fixtures to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fi...

Страница 23: ...your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 PIN XLR plug cable with DMX signal from controller is not connecte...

Страница 24: ...the functionality of the LED indicators Lamp on Lamp on DMX OK DMX OK NO DMX NO DMX Lamp off Lamp off The first LED indicators represents DMX signal If the indicators is on a clean DMX signal is prese...

Страница 25: ...ly readout PASS to confirm a new setting has been made and locked into memory You may exit the main menu at any time without making any adjustments by tapping the MODE ESC button MODE ESC Button To ac...

Страница 26: ...OFF Display turn off after 2mins 11 DISP FLIP ON OFF This function will reverse the display 180 LAAU ON OFF Automatic lamp start with power RDMX ON OFF Change DMX address via external controller DLOF...

Страница 27: ...will immediately begin to flash 3 While the current three digit address is flashing use the Up and Down buttons to select adjust the address Lock your new address into the unit s memory by pressing th...

Страница 28: ...ne and press ENTER 5 Press MODE ESC to return to the main menu AUDI This feature is used to run the internal preset programs in AUDIO mode in either a Master Slave or a stand alone operating mode Foll...

Страница 29: ...Press ENTER to confirm 6 Press MODE ESC to return to the main menu 5 RESE RESET MENU ALL Resets all the motors in the unit SCAN Resets the Pan and Tilt motors ALL When you activate this reset function...

Страница 30: ...mp running time LIFE With this function you can display the total running time of the fixture 1 Access the main menu 2 Tap the UP button until TIME is displayed press ENTER 3 Tap the UP button until L...

Страница 31: ...the UP button to select ON to activate this function or OFF to deactivate this function 5 Press ENTER to confirm 6 Press MODE ESC to return to the main menu 8 RTLT MENU This menu function will reverse...

Страница 32: ...0 1 Access the main menu 2 Tap the UP button until DEGR is displayed press ENTER 3 The display will display 630 540 4 Press the UP button to select 630 or 540 for the pan movement angle 5 Press ENTER...

Страница 33: ...the display will show VALU 4 Tap the UP button until D ON is displayed and tap the ENTER button 5 Press the UP button to select ON to activate this function or OFF to deactivate this function 6 Press...

Страница 34: ...mp when unit is turned on Use this function to turn this feature on and off 1 Access the main menu 2 Tap the UP button until SPEC is displayed press ENTER 3 Tap the UP button until LAAU is displayed p...

Страница 35: ...you want to set the starting address to 57 set channel 1 to a value of 7 set channel 2 to a value of 7 and use channel 3 to set your address to 57 by selecting a channel value of 57 Example 2 If you...

Страница 36: ...l SPEC is displayed press ENTER 3 Tap the UP button until DFSE is displayed press ENTER 4 The display will show ON OFF 5 Press the UP button to display ON to activate this fu o r O F F t o deactivate...

Страница 37: ...ctivate this function 6 Press ENTER to confirm 7 Press MODE ESC to return to the main menu FANS This function is used to change the functionality of the internal cooling fans Follow the procedure belo...

Страница 38: ...buttons to enter the proper password 5 Once the proper password is entered the display will read CHXX were as XX represents the fixture channel number in the case of the Design Par 575H 1 16 6 Select...

Страница 39: ...P or DOWN buttons until REC is displayed then press ENTER 4 After entering the REC function the display will read RE XX where as XX represents the scene number in the internal memory to which the scen...

Страница 40: ...for the scene number For example SC 01 is displayed it means you will be editing scene 1 press ENTER You can change the scene number by tapping the UP button 4 Press ENTER the display will show C 01 t...

Страница 41: ...The number of steps can be defined under EDIT and the scenes can be called up under Run To run the scenes see page 30 Editing procedure 2 Using an external controller 1 Call up the first scene in you...

Страница 42: ...on until EDIT is displayed press ENTER 3 Tap the UP button until RUN is displayed press ENTER 4 AUTO is displayed If you press the UP button it will show SOUN Select which one you want to activate and...

Страница 43: ...ixture into a 6 channel DMX fixture CHANNEL 1 Pan Movement max 630 or 540 User Selectable CHANNEL 2 16bit Pan Movement pan fine CHANNEL 3 Tilt Movement max 265 CHANNEL 4 16bit Tilt Movement tilt fine...

Страница 44: ...0 255 Intensity 0 100 Channel 7 Strobe 0 4 Dimmer 5 255 Strobe effect from slow to fast Channel 8 Lamp on off reset internal programs 0 19 Normal control 20 39 No function 40 59 Lamp on 60 79 Lamp swi...

Страница 45: ...be made If after a third attempt all the errors have not been corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more er...

Страница 46: ...esign Par 575H Elation Professional 46 Design Par 575H malfunctions sensor failed or magnet is missing or there is a stepper motor failure defective motor or a defective motor IC drive on the main PCB...

Страница 47: ...ely 4 Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on installation and usage ha...

Страница 48: ...d with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number...

Страница 49: ...luding warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or...

Страница 50: ...Design Par 575H Elation Professional 50 Design Par 575H 15 PHOTOMETRIC DATA...

Страница 51: ...Design Par 575H Elation Professional 51 Design Par 575H 16 DIMENSIONAL DRAWINGS...

Страница 52: ...Design Par 575H Elation Professional 52 Design Par 575H 17 Circuit Schematic...

Страница 53: ...V 4A 250V GMA 5x20mm fine wire fuse Lamp Options GLA GLC HX 601 HX 600 HX 401 HX 400 Optical system Parabolic glass reflector Includes Medium Lens Lens Options Very Narrow Narrow Medium Wide Color Gel...