I N S T A L L A T I O N I N S T R U C T I O N S
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix
designs to any metal truss/structure, or placing the fixture(s) on any surface, a professional
equipment installer
MUST
be consulted to determine if the metal truss/structure or surface
is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and
accessories.
Fixture ambient operating temperature range is
14° to 113°F (-10° to 45°C)
.
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from
areas were unauthorized personnel might reach the fixture by hand.
NEVER
stand directly below the fixture(s) when rigging, removing, or serving.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable that can hold 10 times the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool before servicing.
TO MAINTAIN IP65 RATING INTEGRITY, AND PREVENT WATER FROM ENTERING
FIXTURE, ALL UNUSED CONECTION RUPPER CAPS MUST BE SEALED.
SEAL ALL UNUSED
CONNECTIONCAPS
SEAL ALL UNUSED
CONNECTIONCAPS