14
S Y S T E M M E N U
Supports Software Version:
≥
V1.08
Features are subject to change without any prior written notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES
(Default Settings in
BOLD
)
DESCRIPTION
Receive
Set DMX Address
001
~ XXX
DMX Address Setting
User Mode
User Mode
Standard
, Basic, Extend, User A, User B, User C Set DMX Channel Mode
Edit A
Max. Chan
:
Chase Fade
Edit User Defined
Channel Assignments
Edit B
Edit C
Function
Status
Remote Add
ON/
OFF
Set Fixture Address Via DMX Control
NoDMX Mode
Hold
/ Auto / Blackout
Function If NO DMX Detected
Pan Invert
ON /
OFF
Pan Reverse Movement
Tilt Invert
ON /
OFF
Tilt Reverse Movement
Pan Degree
630/
540
Pan Degree Select
Feedback
ON
/OFF
Movement Feedback
Move. Spd
Speed
1
~ 4
Movement Mode Select
Stand By
OFF, 01M~99M,
15M
Stand By Mode
Fixture ID
ServicePIN
PIN=XXX
Service PIN
050
RDM PID
XXXXX
RDM PID Code
NOTE: ServicePIN must be entered in order to set fixture IP Address and Universe
Unit IP Addr
XXX.XXX.XXX.XXX.
Enter Fixture's IP Address
Universe
000
-255
Enter Universe Number
ProtocolSet
ArtNet
, SACN
Set Network Protocol
KlingNet
Enable
/
Disable
Enable KlingNet Protocol
Net Switch
ON
/ OFF
Activate NET OUT Port.
Fan. Set
Head Fan
Auto
, High, Low
Fan Speed Set
LCD. Set
Backlight
02~60m
05m
LCD Backlight Shut Off Time
FlipDisplay
ON /
OFF
Flip/Reverse LCD Display 180º
Key Lock
ON /
OFF
Control Front Panel Buttons Key Lock
Disp Flash
ON
/ OFF
Display flashes when NO DMX
Dim Curve
Standard
, Stage, TV, Architectur, Theatre
Set Dimmer Curve Mode
Temp. C/F
Fahrenheit
/Celsius
Temperature Switch Between F˚/ C˚
Init. Effect
PAN =XXX
Initial Effect Position
Disp. Set
Chan. Value
PAN...
Value of each Channel Displayed
Slave Set
Slave 1
, Slave 2, Slave 3
Set Slave Mode Preset
Auto. Pro
Alone
, Master
Set Auto Program Mode
Pixel
Standard
, Flip
Set Pixel Flip Mode
DFSE
ON /
OFF
Restore Factory Settings
Information
Time. Info
Current
XXXX (Hours)
Fixture Run Time From Power ON
Total Time
XXXX (Hours)
Fixture Total Run Time
Last Clear
XXXX (Hours)
Clear Fixture Last Run Time
Timer PIN
PIN=
066
Enter PIN to Access Clear Last. Menu
Clear Last
ON /
OFF
Reset Fixture Last Run Time
Temp. Info
Head Temp.
XXX
F°
/
C°
Temperature in Fixture Head
Error Info
Error Record 1 ~ Error Record 10
Display 10 Recent Error Messages
Model. Info
ChorusLine16
Display Model Name
Software Version
1U01 - 5U01
≥
V1.08
Software Versions