FLAMMABLE MATERIAL WARNING 

Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. 

ELECTRICAL CONNECTIONS 

A qualified electrician should be used for all electrical connections and/or installations. 

USE  CAUTION  WHEN  POWER  LINKING  OTHER  MODEL  FIXTURES  AS  THE  POWER 
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS 
FIXTURE. CHECK SILK SCREEN FOR AMX AMPS. 

MINIMUM DISTANCE TO OBJECTS/SURFACES 
MUST BE 6.6 FEET (2 METERS) 

MINIMUM DISTANCE OF INFLAMMABLE MATERIALS 
FROM THE SURFACE 1.6 FEET (0.5 METER) 

MAXIMUM TEMPERATURE OF EXTERNAL SURFACE 185° F (85°C) 

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED! 

Fixture 

MUST

  be  installed  following  all  local,  national,  and  country  commercial  electrical  and  construction 

codes and regulations. 
Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing the fixture(s) 
on any surface, a professional equipment installer 

MUST

 be consulted to determine if the metal truss/structure 

or  surface  is  properly  certified  to  safely  hold  the  combined  weight  of  the  fixture(s),  clamps,  cables,  and 
accessories. 

Fixture ambient operating temperature range is 

14° to 113°F.

 

(-10° to 45°C)

Do not use the fixture under or above this temperature. 
Fixture(s)  should  be  installed  in  areas  outside  walking  paths,  seating  areas,  or  away  from  areas  were 
unauthorized personnel might reach the fixture by hand. 

NEVER

 stand directly below the fixture(s) when rigging, removing or servicing. 

Overhead  fixture  installation  must  always  be  secured  with  a  secondary  safety  attachment,  such  as  an 
appropriately rated safety cable. 
Allow approximately 15 minutes for the fixture to cool down before servicing. 

RIGGING 

Overhead  rigging  requires  extensive  experience,  including  amongst  others  calculating  working  load 
limits, installation material being used, and periodic safety inspection of all installation material and the 
fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can 
result in bodily injury. 

ALWAYS ATTACH AN APPROPRIATELY RATED SAFETY CABLE (NOT INCLUDED) THAT MEETS ALL 
LOCAL, NATIONAL, AND COUNTRY CODES AND REGULATIONS WHENEVER INSTALLING FIXTURE IN 
A SUSPENDED ENVIRONMENT! 

 

 

Содержание Artiste REMBRANDT

Страница 1: ......

Страница 2: ...d direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elatio...

Страница 3: ...delines 8 Fixture Overview 9 Colors Animation Wheel 11 SpectraColor Guide 12 Fan Modes and Low Noise Operation 13 Lens Installation Replacement 14 Installation Guidelines 15 System Menu 18 DMX Channel Functions and Values 26 Error Codes 35 Specifications 36 Dimensional Drawings 37 Optional Accessories 39 ...

Страница 4: ...Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Fresnel Lens installed Omega Brackets x2 Locking Power Cable CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs Also visit forums elationlighting com with questions comments or suggestions ELATION SERVICE USA Monday Friday 8 00am to 4 30pm PST 323 582 3322 Fa...

Страница 5: ... parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after J...

Страница 6: ...BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURES WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND OR REPAIRS DO NOT PLUG FIXTURE INTO A D...

Страница 7: ...he power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connector into the fixture If the power cord or any of its connectors are damaged replace it immediately with a new one of similar power rating DO NOT block any air ventilation slots All fan and air inlets must remain clean an...

Страница 8: ...rized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tighten...

Страница 9: ...able 2 Tilt Lock 3 System Menu Display 4 MODE ESC Button 5 LEFT Button 6 ENTER Button 7 DOWN Button 8 RIGHT Button 9 UP Button 10 PAN Lock 11 Carrying Handle s 12 RJ45 Input Output 13 5pin DMX Output 14 5pin DMX Input 15 Service Port 16 Fuse 17 Service Port 18 IP65 Locking Power Input ...

Страница 10: ... ensure the fixture performs at its best with the highest output and optimal field Taking over focus control for example to adjust the sharpness of the animation wheels or internal framing module simply set the focus channel within its normal range from DMX 11 to 255 All optimizations are disabled Do not forget to set the focus back to the Optimization range when the effect is removed from the bea...

Страница 11: ...mation wheels one Dot and one Radial allow for independent directional motion including overlapping and counter rotating motion effects that are unique to the fixture Using the focus control the beams can be fuzzy and soft to create subtle depth in the wash field or well defined for powerful animation projection or mid air beam effects Interesting effects can be created by overlapping both wheels ...

Страница 12: ...ure of 6500K to 2700K Full CTO in combination with Cyan Magenta or Yellow allow for a warmer color palette For example Yellow shifts from a slightly greenish tone to a warm amber yellow Utilizing the adjustable CTO with the CMY system greatly enhances the color range of the Rembrandt Using Pure Colors Pure Red Green or Blue are ideal colors to create subtle hues to saturated colors Mixing a slight...

Страница 13: ...ature Auto is the recommend mode for daily operation of the Artiste Rembrandt Low In this mode the fixture reduces fan speeds throughout for a lower noise profile of the fixture This mode should be sufficient for most uses where lower noise is required The fixture output is reduced to about 80 High This mode is only required in very high ambient temperatures when automatic fan speed adjustments ar...

Страница 14: ...d cable and carabiner into notch align Lens Screws with holes and tighten 4x M3 Hex Screws with hexagonal screwdriver Note The correct lens type Fresnel or PC must be selected in the menu or via the DMX control channel to ensure that the focus lens is positioned for the highest output 4x integrated M3 Hex Head Lens Assembly screws Tighten 4x screws with M3 hexagon Allen Screwdriver Align notch wit...

Страница 15: ...e metal truss structure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Fixture ambient operating temperature range is 14 to 113 F 10 to 45 C Do not use the fixture under or above this temperature Fixture s should be installed in areas outside walking paths seating areas or away from areas were unauthorized personnel might reach th...

Страница 16: ...ckets can be installed into the fixture base as illustrated below CLAMP INSTALLATION When mounting fixture to truss be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 screw fitted through the center hole of the Omega Brackets The fixture provides a built in rigging points for a SAFETY CABLE not included Be sure to only use one of t...

Страница 17: ...ior housing and or penetrate the front lens opening of ELATION lighting fixtures can cause severe internal damage including burning to optics dichroic color filters glass and metal gobos prisms animation wheels frost filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific to ELATION lighting fixtures it is a common issue with lighting fixtures from all manufac...

Страница 18: ...ferent functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button To access...

Страница 19: ... Select Lens Hibernation OFF 01M 99M 15M Stand By Mode Service Setting Password Password 050 Service Password RDM UID XXXXXX XXXXXXXXXXXX Set RDM UID PSWD Required Clear Err Info ON OFF Clear Error Info PSWD Required Password 11 enable FollowSpot function use password 60 to open wireless related menu USB Update YES NO Service Port Software Updates Fans Control Auto High Low Studio Mute Select Fan ...

Страница 20: ...rams To Be Run Auto Pro Part2 Program 1 10 Program 1 10 Auto Pro Part3 Program 1 10 Program 1 10 Edit Program Program 1 Pro Test Testing Program Step 01 SCxxx Program In Loop Program 10 Step 64 SCxxx Save and Exit Edit Scenes Edit Scene 001 Edit Scene 250 Pan Tilt Save and Automatically Return Fade Time Scene Time Manual Scenes Edit Input By Outside Stores Scenes via Ext DMX Console Rec Controller...

Страница 21: ...t the DMX value of Channel 1 on the controller to 7 3 Set the DMX value of Channel 2 on the controller to 7 or 8 When set to 7 the DMX address can be set between 1 and 255 When set to 8 the DMX address can be set between 256 and 511 4 Using Channel 3 on the controller set the desired DMX address of the fixture Example 1 If the desired DMX address is 57 set Channel 1 to a value of 7 set Channel 2 t...

Страница 22: ...sonality main menu Service Setting USB Update sub menu 5 Select the software file name on the menu display and press ENTER 6 Select YES to begin update process and Updating will show on the menu display 7 After file is uploaded the fixture will check the software which will take some time The fixture will perform a reset process when the software update process is complete 8 Remove the USB flash d...

Страница 23: ...his function can result in undesired operation this function has been password protected The password is 050 and must be entered each time the calibration menu function is entered Because calibration is an extremely delicate procedure instructions on performing this action are left out of this manual For a first time calibrator please contact our customer support team for step by step instructions...

Страница 24: ...ess MODE ESC in order to return to the main menu 3 Program Selection for Auto Pro Part Select Edit Program Press ENTER to confirm Select Select Programs Press ENTER to confirm Select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press ENTER to confirm Press MODE ES...

Страница 25: ...mbers A maximum of 250 scenes can be programmed Press ENTER to confirm Press MODE ESC in order to return to the main menu Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments See graph...

Страница 26: ...bit 127 0 255 Fine control of Pan movement 3 3 TILT Movement 8bit 127 0 255 Tilt Movement 4 4 Tilt Fine 16bit 127 0 255 Fine control of Tilt movement 5 5 Cyan 0 0 255 Cyan 0 100 Cyan 6 Cyan Fine 0 0 255 Cyan Fine 6 7 Magenta 0 0 255 Magenta 0 100 Magenta 8 Magenta Fine 0 0 255 Magenta Fine 7 9 Yellow 0 0 255 Yellow 0 100 Yellow 10 Yellow Fine 0 0 255 Yellow Fine 8 11 CTO 0 0 255 CTO 0 100 CTO 12 C...

Страница 27: ... Zoom default 11 255 Focus edge adjustment 14 22 Focus Fine 0 0 255 Focus adjustment Fine 15 23 Zoom 138 0 20 Zoom Overdrive small to large 21 255 Zoom small to large 16 24 Zoom Fine 127 0 255 Zoom adjustment Fine 17 25 Shutter strobe 50 X 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No function shutter open 128 159 Pulse effect in sequences 160 191 No...

Страница 28: ...s 139 7 0s 140 8 0s 141 9 0s 142 255 Idle 20 29 Iris 0 0 191 Max diameter to Min diameter 192 223 Pulse opening fast to slow 224 255 Pulse closing slow to fast 30 Iris Fine 0 0 255 Iris Fine 21 31 Frost 0 0 127 Open to Medium Frost 128 255 Open to Heavy Frost 22 32 Animation wheel1 0 0 127 Open 8 255 Animation min to max 23 33 Animation Index Animation rotation 1 0 0 127 Animation indexing 128 189...

Страница 29: ... Speed Of CMY Colour macro Speed 0 0 255 Speed Max Min 37 Colour macros CMY and colour wheel 0 X 0 31 OFF 32 39 Macro1 40 47 Macro2 48 55 Macro3 56 63 Macro4 64 71 Macro5 72 79 Macro6 80 87 Macro7 88 95 Macro8 96 103 Macro9 104 111 Macro10 112 119 Macro11 120 127 Macro12 128 135 Macro13 136 143 Macro14 144 151 Macro15 152 159 Macro16 160 167 Macro17 168 175 Macro18 176 183 Macro19 184 191 Macro20 ...

Страница 30: ...Fine 30 46 Blade 3A 0 0 255 Open to Close 47 Blade 3A Fine 0 0 255 Open to Close Fine 31 48 Blade 3B 0 0 255 Open to Close 49 Blade 3B Fine 0 0 255 Open to Close Fine 32 50 Blade 4A 0 0 255 Open to Close 51 Blade 4A Fine 0 0 255 Open to Close Fine 33 52 Blade 4B 0 0 255 Open to Close 53 Blade 4B Fine 0 0 255 Open to Close Fine 34 54 Framing Index Rotation 127 0 127 Index 0 360 degrees 128 189 CW r...

Страница 31: ...cro12 104 111 Macro13 112 119 Macro14 120 127 Macro15 128 135 Macro16 136 143 Macro17 144 151 Macro18 152 159 Macro19 160 167 Macro20 168 175 Macro21 176 183 Macro22 184 191 Macro23 192 199 Macro24 200 207 Macro25 208 215 Macro26 216 223 Macro27 224 231 Macro28 232 239 Macro29 240 247 Macro30 248 255 Macro31 58 Pan Tilt Speed 0 X 0 225 Max to min speed 226 235 Blackout by movement 236 245 Blackout...

Страница 32: ...io 50 59 Fan Control Low 60 69 Fan Control High 70 79 Fan Control Auto Default 80 84 All motor reset 85 87 Pan Tilt reset 88 90 Color reset 91 93 Idle 94 96 Focus and Zoom reset 97 99 Other motor reset 100 168 Refresh Rate Hz 1s 100 900 101 910 102 920 103 930 104 940 105 950 106 960 107 970 108 980 109 990 110 1000 111 1010 112 1020 113 1030 114 1040 115 1050 116 1060 117 1070 118 1080 119 1090 1...

Страница 33: ...0 127 1170 128 1180 129 1190 130 1200 131 1210 132 1220 133 1230 134 1240 135 1250 136 1260 137 1270 138 1280 139 1290 140 1300 141 1310 142 1320 143 1330 144 1340 145 1350 146 1360 147 1370 148 1380 149 1390 150 1400 151 1410 152 1420 153 1430 154 1440 155 1450 156 1460 157 1470 158 1480 159 1490 160 1500 ...

Страница 34: ...Pan Tilt break default 191 200 Fast mode Pan Tilt break 201 210 Dimmer Curve Linear default 211 220 Dimmer Curve Square 221 230 Dimmer Curve Inverse Square 231 240 Dimmer Curve S Curve 241 Internal program 1 scene1 8 of EEPROM 242 Internal program 2 scene9 16 of EEPROM 243 Internal program 3 scene17 24 of EEPROM 244 Internal program 4 scene25 32 of EEPROM 245 Internal program 5 scene33 40 of EEPRO...

Страница 35: ... therefore the fixture will place itself in a stand by mode until subsequent repairs can be made Less Than 3 Errors The fixture has less than 3 errors therefore most other functions will work properly The fixture will attempt to operate normally until the errors can be correct by a technician The errors in question will remain flashing in the display as a reminder of internal errors Error Codes su...

Страница 36: ...c Shutter and Strobe Adjustable LED Refresh Rate Frequency COLOR SpectraColor CMY RGB color mixing array 6 Dichroic Colors including High CRI Filter UV Linear CTO Color Correction CONTROL CONNECTIONS 2 DMX Channel Modes 35 59 Ch 16 bit Pan Tilt and Dimming Control DMX RDM Art NET and sACN Protocol Support 6 Button Touch Control Panel Full Color 180 Reversible LCD Menu Display Hibernation Mode Powe...

Страница 37: ...37 D I M E N S I O N A L D R A W I N G S W F R E S N E L L E N S Specifications and improvements in the design of this unit and this manual are subject to change without notice ...

Страница 38: ...38 D I M E N S I O N A L D R A W I N G S W P C L E N S O P T I O N A L Specifications and improvements in the design of this unit and this manual are subject to change without notice ...

Страница 39: ... can radiate radio frequency energy and if not installed and used in accordance with the included instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the device off and on the u...

Страница 40: ......

Отзывы: