![Elastic Networks ELMo 120 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/elastic-networks/elmo-120/elmo-120_installation-and-maintenance-manual_2375712022.webp)
2-6 ELMo 120 Multiplexer installation and testing
Revision 2.01
ELMo 120 Multiplexer Installation and Maintenance Guide
08-01023-01
Task:
Connecting power to the ELMo 120 Multiplexer
modem shelf
Use this procedure to install the power feeds from a -48 V dc power source to
the ELMo 120 Multiplexer modem shelf.
Note: The voiceband filter shelf does not require a power feed.
Requirements
This procedure requires the following:
•
volt-ohm meter
•
ELMo 120 Multiplexer power harness
•
-48 V dc power fuse bay or dc rectifier
Power supply and wiring specifications are described in Appendix A.
Action
Step Action
1
Eject all cards (Power, Switch, and Modems) from the backplane of the shelf.
Ensure that the cards completely dislodge from their backplane connectors.
2
Route and connect a ground wire from the building’s grounding facility to the
ground stud on the shelf side-flange. See Appendix A, “Grounding
environment specifications” on page A-3 for ELMo 120 Multiplexer grounding
requirements.
—continued—
!
CAUTION
Serious equipment damage
Never connect untested power to the ELMo 120 with any circuit
packs installed. If the power feed polarities happen to be
reversed, the ELMo 120 shelf and rectifier could be seriously
damaged.
Содержание ELMo 120
Страница 2: ......
Страница 4: ...ii Revision 2 01 ELMo 120 Multiplexer Installation and Maintenance Guide 08 01023 01 ...
Страница 6: ...Revision 2 01 ELMo 120 Multiplexer Installation and Maintenance Guide 08 01023 01 iv ...
Страница 10: ...viii About this document Revision 2 01 ELMo 120 Multiplexer Installation and Maintenance Guide 08 01023 01 ...
Страница 70: ...I 4 Index Revision 2 01 ELMo 120 Multiplexer Installation and Maintenance Guide 08 01023 01 ...
Страница 71: ......