INSTALLATION MANUAL
VIA!Valet6.4
Installation (cont’d)
VIA!Valet6.4 Touch Panel Connections
The VIA!Valet6.4 Touch Panel comes with a 12’ pre-terminated bun-
dled cable which include both Cat-5 and RG-59 coax cable. To
attach the bundled cable between the VIA!Valet6.4 Touch Panel and
the PVIA1 Valet Wall Plate:
1. Connect one end of the RG-59 cable to the VIDEO IN port
on theVIA!Valet6.4 Tocuh Panel. Connect the other end to the
VIDEO OUT jack on the PVIA1 Valet Wall Plate.
2. Connect one end of the RJ45 cable labeled “SYS” to the SYS
port on the VIA!Valet64. Connect the other end to the
TO VIA VALET jack on the PVIA1 Valet Wall Plate.
3. Optional Local Port Connection:
The LOCAL port is not normally used with the VIA!Valet6.4.
If you need to use the LOCAL port, connect the RJ45 connec
tor labeled “LOCAL” to the LOCAL port on the VIA!Valet6.4.
Connect the other end to other locally controlled compo-
nents.
SYSS
Y
S
IR
OUT
VIDEO OUT
9VDC PWR9
16VDC PWR1
TO VIA VALET
12’ Pre-terminated
bundled cable
From VIA!Valet6.4
Touch Panel
SYS
SYS
To PVIA1 Valet
PVIA1 Valet
VIA!Valet6.4
INSTALLATION TIP:
The LOCAL port is not normally used with the
VIA!Valet6.4. If not using the local connection
ELAN recommends removing the unused
Cat-5 cable by peeling it from the 3-cable
pre-terminated bundle and discarding.