© ELAN Home Systems 2005 • All rights reserved. Page 31
E L A N H O M E S Y S T E M S
INSTALLATION MANUAL
VIA!4.0
Installation - Connections Beyond 220 Feet (cont’d)
ELAN Z•System
Use local a local PVIA1 to connect a VIA!4.0 to a PZ6 Precision Panel
located more than 220 feet away.
ELAN HD System
Use a local PVIA1 to connect a VIA!4.0 to an ELAN PHD12 Precision
Panel located more than 220 feet away.
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
SIR
N/C
PVIA1 Rear
GND
P & DB
Zone 1 Shown
<110 Feet
>220 Feet
White/Blue
Orange
White/Orange
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
Green
Brown
PWR1
PZ6
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
SIR
Green
PVIA1 Rear
<110 Feet
>220 Feet
PHD12 TELCO/DB2
Punchdown Connector
N/C
N/C
Brown
Blue
White/Blue
PWR1
Use
BOTH
Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)
Use
BOTH
Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)