ELAD DUO-ART 60
User Manual - Rev. 1.3 - 04/2018
© 2018 ELAD S.r.l. All rights reserved. No part of this document may be reproduced, published, used, disclosed or disseminated
in any form or by any means, electronic, photocopying or otherwise, without prior written permission of ELAD S.r.l.
11
Name
Type
Code
Description
Warning
W-130
The DUO-ART is in REMOTE mode but the active interface
is not FDMDUO.
Warning
W-131
Reporting a communication problem between the DUO-
ART and the FDM-DUO.
Warning
W-145
Indicates an internal communication problem. After
"warn" a code composed of alphanumeric characters is
added.
Warning
W-146
Indicates an internal problem of the operation of the
DUO-ART.
This
problem
resolves
automatically.
Warning code: ST-P10-b3.
Warning
W-147
Indicates the inability to perform an internal operation.
Warning
W-148
Automatic activation of the stand-by following an
unauthorized transmission.
Warning code: ST-P10-b2.
Warning
W-160
This warning appears when the maximum time available
for automatic tuning of the antenna expires. This time can
be set from the "AutoTune Timeout" menu.
Warning
W-161
This warning appears if the target SWR has not been
reached after the time-out has been set. This warning is
only displayed if the "Target SWR" menu is set to a value
other than 0.
Warning
W-162
The FDM-DUO has left the tuning mode (Tune) before the
DUO-ART. This warning is displayed if the tuning mode of
the FDM-DUO times out or if the FDM-DUO detects a high
SWR.
Warning
W-163
This warning appears if the DUO-ART has found a tuning
point but the calculated SWR is too high.
Warning
W-175
High temperature warning.
Error
E-400
Maximum temperature exceeded.
This error cannot be
reset
. It is necessary to wait for the temperature to
decrease before you can use the DUO-ART amplifier again.
High
temperature
High
temperature
Auto Tune
Max SWR
Auto Tune
DUO aborts
Auto Tune
SWR warning
Auto Tune
timeout
Band warn
StBy
CMD not
available
Micro Reset
warning
Comm
warn
DUO EXTIO
warning
DUO mode
not activated