Parity
Set the data is the parity.
Permitted values:
o
N = No parity bit (Default).
o
E = Even parity.
o
O = Odd parity.
Stop_Bits
Sets the number of stop bits.
Permitted values:
o
1 = 1 stop bit (Default).
o
2 = 2 stop bits.
Flow_Control
Sets the flow control type.
Permitted values:
o
0 =
o
1 =
4.10
S
ERIAL
C
OMMANDS
S
ETUP
The serial commands configuration parameters are as follows where ‘X’ is for commands 1
to 4 (Default values are shown):
Command_0X_Enabled
Command_0X_Serial_Port
Command_0X_Data_Type
Command_0X_Data
= 0
= 1
= H
= 0
Each configuration parameter and its permitted values are as follows:
Enabled
Enables or disabled the specified command from being
transmitted or showing in the serial log files.
Permitted values:
o
0 = Disabled (Default).
o
1 = Enabled.
Serial_Port
Specifies the data type of the data sent out the specified serial
port.
Permitted values:
o
H = Hexadecimal format.
o
S = String of characters.
Data_Type
Specifies the data type of the data sent out the serial port.
Permitted values:
o
H = Hexadecimal format.
o
S = String of characters.
Data
The data command sent out the serial port. The maximum
length of the serial data command is 255 characters (Default =
0)