background image

Manual

WARNING!

400V

VARNING!

FÅR EJ ÖVERTÄCKAS

OBS!

BYT FILTER 

REGELBUNDET

A 155F / A 155HW

Содержание A 155F

Страница 1: ...Manual WARNING 400V VARNING F R EJ VERT CKAS OBS BYT FILTER REGELBUNDET A 155F A 155HW...

Страница 2: ...t under anv ndning Avfuktarens luftintag och luftutsl pp f r aldrig t ckas ver under drift Skyddsk por och t ckpl tar f r aldrig tas bort under drift Produkten r inte avsedd att anv ndas av personer i...

Страница 3: ...typ av torkning och klimatreglering i andra lokaler Avfuktaren skall anv ndas i lokaler som r uppv rmda 15 35 C TEKNISK DATA M tt H x B x D 1500 x 470 x 370 mm Vikt 70 kg Elanslutning 3N 400V PE Avs...

Страница 4: ...det vre 15 mm r ret Extern magnetventil monteras f r att reglera fl det Denna styrs via termostat i avfuktaren Anslut magnetventilen till 7 8 i plintraden i maskinen Vattentemperaturen b r vara 55 C...

Страница 5: ...tt reglera drifttiden Montera timern p l mplig plats t ex innanf r d rren i torkrummet och anslut enligt f ljande Anv nd kabel med min area 0 75 mm Koppla in mellan timerns och avfuktarens plintar 3 4...

Страница 6: ...g av drifttid Om torkrumsavfuktaren r f rsedd med timer med f rinst lld tid st ll in den aktuella tiden enligt f ljande 1 St ng av str mmen till torkrumsavfuktaren via arbetsbrytaren 2 ppna locket p t...

Страница 7: ...denna verhettningsskydden sitter h gst upp bakom luckan verhettningsskydd GT3 GT3 r ett verhettningsskydd som r placerat i v rme batteriet och bryter man verstr mmen till kontaktor K3 vid 70 C GT3 te...

Страница 8: ...Kontrollera att luftfl det r ok genom avfuktaren Om filtret r igensatt f rs mras luftfl det med l ngre torktid som f ljd Kontrollera att kompressor g r Om temperaturen i torkrummet r l gre n 20 C kan...

Страница 9: ...den p avfuktarens typskylt Typskylten sitter p v nster sida h gst upp p avfuktaren OBS BYT FILTER REGELBUNDET WARNING 400V KL604233 GT2 1 och GT2 2 1 2 times year 604503 TRANSPORT Avfuktaren skall all...

Страница 10: ...es Safety during assembly Electrical connection to power outlets and any additional equipment e g timers shall be performed by a qualified electrician Safety during use The humidifier s air inlet and...

Страница 11: ...55 C Water flow 5 6 l min Power 3 4kW Air flow free circulation 1300 m3 h Refrigerant type R134a GWP effect R134a 1300 Refrigerant quantity 870 g Noise level 1 m in front 61dB A IP rating X4 Working...

Страница 12: ...pipe Install an external solenoid valve here to regulate the flow It is regulated by a thermostat GT1 in the dehumidifier Connect it to 7 8 in the terminal strip The water temperature should be 55 C w...

Страница 13: ...r can be fitted as an accessory to the drying room dehumidifier Fit the timer in a suitable place e g inside the door in the drying room and connect the power as follows Use a cable with 1 5 mm2 min a...

Страница 14: ...this manual If the drying room dehumidifier is fitted with a timer with preset time set the required time as follows 1 Turn off the power to the drying room dehumidifier using the main operation swit...

Страница 15: ...the top behind hatch Overheating protector GT3 GT3 is an overheating protector inside the heating coil It breaks the current to contactor K3 at 70 C GT3 resets automatically when the temperature has d...

Страница 16: ...sor is running The heat does not work Make sure the internal thermostat is set as it should Normal setting 7 RESETTING OF OVERHEATING PROTECTION GT2 1 and GT2 2 If the heating coil stops working it ma...

Страница 17: ...jected to cold it should be left standing in a warm room until it reaches room temperature SCRAPPING Take the dehumidifier to a recycling station according to state or local regulations WARRANTY El Bj...

Страница 18: ...it nn t on annettava valtuutetun s hk asentajan teht v ksi Turvallisuus k yt n aikana Kuivaimen ilmanotto ja ilmanpoistoaukkoa ei saa koskaan peitt k yt n aikana Suojakoteloita ja peitelevyj ei saa ko...

Страница 19: ...en kuivaukseen ja muiden tilojen ilmastons t n Kuivainta on k ytett v l mmitetyiss tiloissa 15 35 C TEKNISET TIEDOT Mitat K x L x S 1500 x 470 x 370 mm Paino 70 kg S hk liit nt 3N 400 V PE Sulake 10 A...

Страница 20: ...s t miseksi asennetaan ulkoinen magneettiventtiili Sit ohjataan kuivaimen termostaatilla Liit magneettiventtiili koneen liitinrivin paikkoihin 7 8 Veden l mp tilan on oltava 55 C kun delta on 10 C ves...

Страница 21: ...t miseksi Asenna ajastin sopivaan paikkaan esim oven sis puolelle kuivaushuoneessa ja liit se seuraavasti K yt kaapelia jonka poikkipinta ala on v hint n 0 75 mm Kytke ajastimen ja kuivaimen liittimie...

Страница 22: ...ssa Langaton ajastin ei kuvattuna t ss ohjekirjassa K yntiajan asettaminen Jos kuivaushuonekuivaimessa on valmiiksi asetetulla ajalla varustettu ajastin s d aika seuraavasti 1 Katkaise kuivaushuonekui...

Страница 23: ...via ja avaa se Ylikuumenemissuoja on ylimp n luukun takana Ylikuumenemissuoja GT3 GT3 on l mmityspatteriin asennettu ylikuumenemissuoja joka katkaisee kontaktorin K3 ohjausvirran 70 C ss GT3 palautuu...

Страница 24: ...ARKISTUSLISTA KUIVAIN KUIVAA HUONOSTI Tarkasta ett ilma virtaa kuivaimen l pi Jos suodatin on tukossa ilmavirta heikkenee ja kuivausaika pitenee Tarkasta ett kompressori k y Jos kuivaushuoneen l mp ti...

Страница 25: ...limp n kuivaimen vasemmalla puolella OBS BYT FILTER REGELBUNDET WARNING 400V KL604233 GT2 1 ja GT2 2 1 2 times year 604503 KULJETUS Kuivainta on aina kuljetettava pystyasennossa Jos se on ollut vaaka...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...El Bj rn AB Box 29 334 21 Anderstorp Tel 0371 588 100 Fax 0371 181 34 info elbjorn se www elbjorn com KL597007 SE_GB_FI 170306...