STEP 4: INSTALLING THE MOUNTING PLATE 

STEP 5: FINISHING THE INSTALLATION 

Screw in the four (4) rubber vibration dampers into the threaded holes 

on the bottom side of the reservoir. Do not use any tools to fasten the 

dampers in to position, use thumbs only. 

Then use enclosed M4x4 DIN 7984 screws to install the metal plate on 

the reservoir using enclosed Allen key 2.5 mm. 
 

Secure  the  metal  plate  through  the  openings  to  the  computer  chassis 

using enclosed M4x6 ISO 7380 screws, washers and M4 nuts. User may 
need to drill 4 (four) 

∅4

 

mm holes through chassis metal using electric 

power drill if there are no appropriate mounting holes available. 

 

 

 

The  EK-XRES  DCP  4.0  offers  three  inlet  (suction)  G1/4  ports.  In  order  to  use  the 

selected port as inlet it is mandatory to use the enclosed EK-Extender G1/4 with the 

G/4 threaded fitting. Use enclosed G1/4 Plugs to plug the remaining two unused ports. 

In order to make air bleeding process easier one can install the enclosed PU mesh in 

the inlet compartment of the XRES. 

 

STEP 6: CONNECTING YOUR RESERVOIR 

 

Connect two G1/4 threaded fittings to the reservoir (IN/suction) and pump (OUT/pressure). Please note the water flow orientation. EKWB recommends 

using  EK-CSQ  fittings  and  EK-CSQ  Adapters  with  the  EK-XRES  DCP  4.0  series reservoirs.  To  ensure  that  the  tubes are  securely  attached  to  the  barb/fittings, 

please use hose clamps or an appropriate substitute.

 

 

STEP 7: FILLING THE RESERVOIR 

Unscrew the top cap and fill the coolant in the reservoir. Make sure the liquid is not spilled over your computer or any electrical devices nearby. Run your pump 

shortly for couple of times to make sure water floods your tubes and other water cooling components. Repeat the procedure until you are done and pay attention 

to  the  water  level  in  your  reservoir.  Lowest  level  of  the  coolant  should  be  at  least  1  cm  above  the  plastic  (Acetal)  base  of  the  reservoir.  The  highest 

recommendable water level is approximately 0.5 cm below the top of the acrylic tube. Once done with the filling process please close your 

EK-XRES DCP 4.0

 

by 

reinstalling the end cap, twisting it clock-wise. 

STEP 8: OTHER INSTRUCTIONS 

VERY IMPORTANT NOTICE: 

Once  the  installation is completed,  it  is a  recommended practice  to  test the  cooling  circuit  for  leaks  prior to  powering  up  the 

computer. We recommend a 24 hour leak test prior to powering up the computer. Do not test the product using tap water pressure. This will rupture the top of 
the  housing  and  render  the  product  unusable  (and  will  void  your  warranty).  While  all  efforts  have  been  made  to  provide  the  most  comprehensive  tutorial 
possible, EK Water Blocks assumes no liability expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water 
Blocks  cooling  products,  either  due  to  errors  or  omissions  on  our  part  in  the  above  instructions,  or  due  to  failure  or  defect  in  the  EK  Water  Blocks  cooling 
products. 

WARRANTY: 

Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final 

user. During this period, products will be repaired or have parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it 
was purchased; (II) the product has been purchased by an end user and has not used for commercial purposes; (III) the product has not been misused, handled 
carelessly, or used in a manner other than in accordance with the instructions provided describing its installation and proper use. This warranty does not confer 
rights other than those expressly set out above and does not cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and 
does not  affect  your statutory  rights  as a  consumer.  This warranty  is voided  if  the  product  comes in  contact  with aggressive  UV  additives or other improper 
liquids.

 

REQUIRED TOOLS: 

Philips head screwdriver

        

Power drill with 4 mm drill bit (optional)

 

 

Water in

 

Water out

 

G1/4 Fitting 

Plastic foam 

DCP 4.0 Pump 

Screw M4x4 
DIN 7984 
 

Rubber 
anti-
vibration 
dumper 

Metal plate 
 

EK-Extender G1/4 

Use these zip holes to mount the 

XRes to the PC chasis using 

enclosed M4×6mm screws and 

nuts. 