background image

 

 

 

 

          

 

Released on 24

th

 of March, 2014 

STEP 5:  CONNECTING YOUR RESERVOIR 

 

 

It is mandatory to use the correct INLET and OUTLET port.

 As an inlet and outlet port you 

have to

 use exactly those ports that are shown in 

the figure below. EK recommends using EK-CSQ compression fittings for best water cooling experience. 

 

STEP 6: FILLING THE RESERVOIR

 

 

1.

 

It is 

mandatory

 to initially fill the pump through G 

1/4 port like shown on figure below, with enclosed 

50ml

 cup of cooling liquid or any other appropriate 

coolant. By doing this you flood the impeller of the 
pump which enables pump to pumps liquid through 
your cooling system. 

If this step is not done 

correctly your pump will not be able to pump 
liquid through your system. You will need to 
repeat this step in order to complete this 
installation properly.

 

2.

 

Close the port with enclosed G1/4 plug. 

 

 

 

 

3.

 

Fill the reservoir fully through G3/8 threaded fill port (marked with arrow) and make sure liquid 

is not spilled over your computer or any electrical devices nearby. 

Run your pump shortly , 

and when the water level reaches dashed line (see figure below) stop the pump. Fill 

the reservoir fully through G3/8 threaded fill port and run the pump shortly. Repeat 

this  procedure  until  your  system  is  fully  filled

.  Lowest  and  highest  recommendable 

operating water levels are indicated on the reservoir's front panel (

MIN

MAX

). Once done with 

the filling process please close your EK-SBAY DDC reservoir with G3/8 plug and tighten is using 

enclosed Allen key. Do not use excessive force. 

4.

 

Secure the bay reservoir with M3x4 DIN 7985 screws mentioned in 

STEP 4

 
 
 

 

 

 

 

 
 
 
 
 

 

STEP 7:  OTHER INSTRUCTIONS  

VERY IMPORTANT NOTICE: 

Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We recommend a 24 hour leak test prior to powering 

up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the block unusable (and will void your warranty).While all efforts have been made to provide the 
most comprehensive tutorial possible, EK Water Blocks assumes no liability expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either 
due to errors or omissions on our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

WARRANTY: 

Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this period, products will be repaired or have 

parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was purchased; (II) the product has been purchased by an end user and has not used for commercial purposes; (III) the 
product has not been misused, handled carelessly, or used in a manner other than in accordance with the instructions provided describing its installation and proper use. This warranty does not confer rights other than 
those expressly set out above and does not cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is voided if 
the product comes in contact with aggressive UV additives or other improper liquids. 

 

REQUIRED TOOLS: 

 

 

 

   

 

Philips and Torx T20 head screwdriver 

 

OUTLET

 G1/4 

threaded port 

INLET

 G1/4 

threaded port 

EK-CSQ 
compression fittings 

EK G1/4 threaded plug with slot 
for 5mm LED diode (enclosed). 

During filling your tubes 
and other water cooling 
components water level 
must not fall under dashed 
line as shown on figure.   

G 3/8 threaded fill port 

During this procedure G 3/8 
threaded fill port must be 
opened. 

!!! During this procedure G 1/4 
threaded fill port must be sealed !!! 

Отзывы: