background image

All disclosures, notices and warranty conditions are being written on the EKWB website. Please read terms of use.                         Released on 15

th

 of March, 2013. Revision 1.1 

 

 

PLEASE NOTE: 

1.

 

Only one port must be used as inlet and one port as outlet! 

2.

 

Ports can be exchanged, meaning inlet can be used as outlet and at the same time outlet can be used as inlet. 

 
STEP 4:  ATTACHING THE EK-FC TERMINAL INTERCONNECT  
 

Please take the following steps for installing any EK-FC Terminal interconnect to your graphics cards water blocks: 

1.

 

Remove the preinstalled FC Single Terminal from the water block using 2,5mm Allen key by unfastening three M4 Screws. 

2.

 

Save the O-ring gaskets and M4 Screws from the FC Single Terminal. 

3.

 

Install OR 15x1 mm O-ring gaskets in grooved slots on the EK-FC Terminal interconnect. Make sure the gaskets are installed correctly! Each water 

block or blank link requires two (2) gaskets! 

4.

 

Secure the EK-FC Terminal interconnect with M4x28 DIN7984 Screws (enclosed) using the enclosed Allen (hex) key 2.5mm! 

5.

 

If necessary plug all unused Terminal ports using appropriate EK-FC Terminal Blank Links (Serial or Parallel – depending on the type of your 

bridge). When using EK-FC Terminal Blank Links make sure you follow installation guides provided with the Blank Links. 

6.

 

Plug all unneeded G1/4 threaded ports using Allen (hex) key 6mm (if needed) and install inlet/outlet fittings. EK recommends EK-PSC and EK-CSQ 

compression fittings. 

 

STEP 5:  OTHER INSTRUCTIONS  

VERY IMPORTANT NOTICE: Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We recommend a 24 hour leak test prior to 
powering up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the block unusable (and will void your warranty).While all efforts have been 
made to provide the most comprehensive tutorial possible, EK Water Blocks assumes no liability expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water 
Blocks cooling products, either due to errors or omissions on our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

WARRANTY: Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this period, products will be repaired or 
have parts replaced at our discretion provided that: 

(I)

 

the product is returned to the agent from whom it was purchased; 

(II)

 

the product has been purchased by an end user and has not used for commercial purposes; 

(III)

 

the product has not been misused, handled carelessly, or used in a manner other than in accordance with the instructions provided describing its installation and proper use. 

This warranty does not confer rights other than those expressly set out above and does not cover any claims for consequential loss or damage. 

This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. 

This warranty is voided if the product comes in contact with aggressive additives or other improper liquids. 

 

REQUIRED TOOLS: 

 

 

 

 

Allen (hex) key 6mm & 2.5mm (both enclosed).

 

 For 

support

 please visit: 

www.ekwb.com/support

 

For 

product suggestion

 please visit: 

thinkcell.ekwb.com

 

 

EK-CSQ type compression fitting 

EK-Plug G1/4 

EK-FC Terminal series interconnect 

Screw M4x28 DIN7984 

OR 15x1mm 

gasket 

!!! A T T E N T I O N !!! 

!!! DO NOT OVERTIGHTEN THE 

SCREWS !!! 

DOING SO WILL RENDER YOUR 

WATER BLOCK USELESS! 

Once the feel the screw grab, 

use no more than ¼ of the turn. 

Отзывы: