All disclosures, notices and warranty conditions are being written on EKWB web page.  Please check terms of use.                    Revision 1.0. Published on October 30

st

, 2014   

PLACING SB AND MOSFET BLOCK ON MOTHERBOARD. Place the EK-FB KIT GA-X99 LE water block with pre-installed standoffs gently to the motherboard or vice versa. Make 
sure that mounting holes are aligned. 

Between block and PCB use plastic washer and glue it on standoffs if not pre-glued!!!

  

 

  

 

 

 

 
 

 

  

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 4:  ATTACHING THE BLOCK TO THE MOTHERBOARD 

 

STEP 5:  CHECKING FOR CONTACTS 

Prior to fastening the screws please make sure the mounting holes on the motherboard’s 

circuit board are aligned with water block. 

 

Use 4 screws four for attaching M2.5x4 and 2 (two) M3x4 DIN7985 screws and 6 (six) PVC 

washers. Tighten the screws, beginning near the center of the board and continue evenly 

outwards. EK recommends installing loosely first all the screws and only then start fastening 

them. Do not use excessive force when tightening the screws! Use the enclosed screws and 

washers as shown in picture below:  

 

 

  

 

Temporarily remove the water block to check for uniform surface contact between 
the block and the components. Note the pattern of contact on a piece of paper. 
Then repeat steps 3 and 4 to reattach the block applying more or less pressure to 
the areas where you have found it necessary. Note that there is no need for perfect 

thermal pad imprint on the inductors/coils (mentioned in STEP2) 
 
 

 

 

 

 

 
 
                                                                                       

6. POSITIONING FITTINGS AND CONNECTING TO WATER CIRCUIT 

 

Attach the liquid cooling tubes and connect the water-block(s) into the cooling circuit. EKWB recommends using EK-CSQ compression fittings with the EK-FB GA X99 LE series 
water block. You can use any opening as an inlet/outlet port. Plan your tubing routing in advance! 

 

 

       

 

REQUIRED TOOLS AND MOUNTING SCREWS: 

 scissors  

 philips screwdriver    

 thermal grease

 

 

 

EK-CSQ fitting 

Tubing 

Chip die thermal grease imprint 

Thermal pad imprints 

M2.5 x 4 screw 

M3 x 4 screw 

PVC washer M2.5 

PVC washer M3 

Glue plastic washer on standoffs on 
SB and Mosfet block

 if not pre-glued

 

 

Plastic washer M3 

Plastic washer 
M2.5 