background image

 

  

Applications 

 

  

Specification 

 

 

This device complies with part 15 of the fcc rules. Operation is subject to the 
following two conditions :

 

(1) This device may not cause harmful interference, and

 

(2) This device must accept any interference received including interference 

that may cause undesired operation

 

 

 

 

AC/DC

 

Adapter(12V)

 

 
 

 

  How to change the communication password 

(Coax/UTP/2-Wire) 

 

 

All Intercoax EoC converters have the same password as factory 
defaults setting value and can be used immediately when connecting 
to the product (Plug & Play mode).

 

However, if a number of products are mixed in the same area or 
the signal transmission line is in poor condition, the communication 
passwords for each equipment (or group) can be set differently to 
prevent cross-talk between the lines.

 

1. 

Needed items for Joining

 

EoC Converters / Power supply / Short Cable (Coax, UTP, 2-Wire) / 
Paper clip

 

2. 

Product configuration

 

a.  Connect EoC Converters with Coax cable (or UTP, 2-Wire) and 

power to the one of the converters up with power supply.

 

b.  Check if the Power LED on both devices is ON.

 

3. 

Remove the existing password (Unjoining)

 

This process removes passwords that are entered as factory 
defaults.

 

a.  Press the Join button on one of the connected products using a 

paper clip until the Power LED turns off and on (Approximately 
15 seconds)

 

b.  Remove the existing password by pressing the Join button on the 

opposite product in the same way as above.

 

c.  Join LED will be turned off if the password on the devices is 

removed correctly.

 

4. 

Create New Password (Joining)

 

New password for communication between connected devices is 

created and this will block the communication with other devices (or 
group) which have a different password.

 

a.  Press the Join button for 2 seconds on one of the connected 

product using a paper clip and the Join LED of the device will 
flicker at a constant speed. (Stand-by mode)

 

b.  Press the Join button for 2 seconds on the opposite device in the 

same way as above. And then, the Join LED of the device flickers 
at a constant speed and both devices restart at the same time.

 

c.  Then the Join-Link lights up and communications are resumed 

between the products

 

5. 

When adding new products in 1:N configuration to a group that 
has already been joined. (Group Joining)

 

a.  Connect new device to the group which is already joined. (using 

T-BNC or Y-UTP coupler, Terminal block)

 

b.  Remove the password of the new device in the same way as step 

‘3-a’.

 

c.  Press Join button on the one of the device of the existing group 

for 2 seconds and Join LED flickers at a constant speed.

 

d.  Press Join button on the new device for 2 seconds and new 

device restarts

 

e.  Join-Link lights up and communications are resumed between 

the products.

 

 
 
 
 
 
 

 

  

Caution 

 

 

  Please install the device following the installation guide.

 

  Do not touch the device and cable with wet hands.

 

  Keep away from moisture and shock.

 

  Do not install near any heat sources such as radiators, heat registers, 

stoves or other apparatus that produce heat.

 

  Indoor use only.

 

  Do not use for other purposes.

 

  Do not disassemble or modify this device.

 

  Do not put any sticker or paint on it.

 

  If this device is defective or malfunctioning, please unplug the power 

adapter immediately and contact dealer or service center.

 

  Please use the rated power supply for the product.

 

  Connect DC power to this device first and then to AC outlet.

 

 

 

  

Warranty 

 

 

  This device has passed the quality control and product inspection.

 

  Please install and use according to the installation guide.

 

  The warranty period for this product is 24 months from the date of 

purchase.

 

  If this device is defective or malfunctioning, please unplug the power 

adapter immediately and contact dealer or service center.

 

  Any damages or breakage from user’s abuse, accident, modification 

or natural disasters will not be covered 

manufacturer’s warranty.

 

 

 
 
 

 

10/100 Ethernet

 

PoE

 

Coaxial Cable

 

PoE 

Camera

 

ECP-2601T

 

56V DC/1.2A

 

Power Supply

 

ECP-2601R

 

NVR

 

PoE Switch

 

10/100 Ethernet

 

Coaxial Cable

 

Non-PoE IP 

Camera

 

ECP-2601T

 

ECP-2601R

 

Please visit below website for more detailed information. 

Web: http://www.intercoax.com Tel: +82. 31. 365. 3133~4

 

E-mail: [email protected] 

Fax: +82. 31. 365. 3135

 

Model 

ECP-2601T 

ECP-2601R

 

 

Interface

 

Coax

 

1 x 

75Ω BNC (Female) - Ethernet over Coax (B-LinX)

 

Ethernet

 

1 x RJ45 - 10/100 Base-T with Auto-detect MDIX

 

Transmission Rate

 

95Mbps Full Duplex 

(270Mbps between Intercoax devices)

 

Transmission 

Distance

 

Ethernet

 

up to 2.4Km(RG-6)

 

PoE (PoC)

 

up to 1.2Km (RG-6 / 7W camera)

 

 

LED

 

Indication

 

Ethernet

 

1 x Data-Link (Yellow)

 

EoC

 

1 x Join-Link (Green)

 

Power

 

1 x Power On(Amber)

 

PoE

 

1 x PoE Out (Red)

 

Encryption

 

128-bit AES

 

 

 

Power

 

Input

 

B-Linx or DC12V~57V

 

PoE Switch or 

DC12V~57V

 

 

PoE Output

 

IEEE802.3af(PoE), 

IEEE802.3at (PoE+),

 

Extra PoE up to 60W

 

PoE Not Supported 

PoC Only

 

 

Mechanical

 

Dimension

 

82.4(L) x 61.6(W) x 24(H)mm

 

Weight

 

77g

 

 

Environment

 

Operating Temp

 

-20 ~ 60°C

 

Storage Temp

 

-30 ~ 80°C

 

Relative Humidity

 

10% ~ 90%

 

 

Compliance

 

Certification

 

FCC, CE, KC

 

Surge Protection

 

IEC 61000-4-5 4kV(1.2 / 50us), 2kA(8 / 20us)

 

Optional Accessories

 

56VDC / 1.2A External Power Supply

 

 

 
 

Содержание 0 685

Страница 1: ... 01 2021 Freigabe U A Seite 1 von 9 pe light S COAX Art Nr 0 685 XXXXXXXXXXXXXX eks Engel FOS GmbH Co KG Schützenstrasse 2 4 57482 Wenden Hillmicke Germany Tel 49 0 2762 9313 600 Fax 49 0 2762 9313 7906 E Mail info eks engel de Internet www eks engel de ...

Страница 2: ...it optischen Instrumenten z B Linsen Mikroskop in den Strahl der optischen Transceiver sehen Missachtung dieser Warnung kann zu Augenschäden führen Sehen Sie nicht in den optischen Sender Das gebündelte und abhängig von der Wellenlänge sichtbare oder unsichtbare Licht kann zu Augenschäden führen This manual contains important notes and warnings that could lead to serious personal and properly dama...

Страница 3: ...eräte der pe light COAX Produktfamilie sind industrielle Komplettlösungen für den Einbau in Lichtmasten aus Stahl mit den folgenden Normen in den aktuellen Fassungen DIN EN 40 5 Anforderungen für Lichtmasten aus Stahl DIN 49778 Lichtmaste Gerätesteg mit Schiebemuttern Der Einbau des pe light COAX erfolgt in einem Laternenmast mit dem Innendurchmesser von 100 mm und einem Türausschnitt von 400x85 m...

Страница 4: ...wer supply downwards and remove it Isolierscheibe abheben remove insulating plate Zugentlastung lösen release strain relief Kabeleinsatz abheben remove cable break Koaxkabel anschließen connect COAX cable Isolierschiebe wieder einlegen reinsert insulating plate Netzteil einschieben und fixieren place power supply and tighten the screw Klemmenblock aufrasten mount screw terminal Netzanschlusskabel ...

Страница 5: ... internen COAX Medienwandler zum Switch in einen der vier M12 GB Ethernet Ports des Switches einschrauben Die drei freibleibenden M12 Anschlüsse können von Kundenapplikationen genutzt werden Connect the ethernet cable coming from the internal COAX converter to one of the four M12 GB Ethernet ports of the switch The three remaining M12 ports can be utilized by the end user ...

Страница 6: ...gnet Security advice pe light S COAX is only suitable for metal pole according to DIN EN 40 with door according to DIN 48778 Erdungskabel anschließen pe light COAX in Türöffnung setzen Gehäuse mit beiden Befestigungsschrauben im Mast fixieren Connect earth wire insert pe light COAX into the pole fasten the housing with upper and lower fixing screw Abmessungen Dimensions Masteinbau Pole installatio...

Страница 7: ...stigungsmöglichkeit Mounting options Hakenbefestigung im Laternenmast Hook fastening in lantern pole Betriebstemperatur Operating temperature 20 C bis 60 C 20 C to 60 C Lagertemperatur Storage temperature 30 C bis 80 C 30 C to 80 C Luftfeuchtigkeit Humidity 10 95 rHd nicht kondensierend 10 95 rHd non condensing EMV EMC DIN EN 55032 2016 02 Klasse A DIN EN 61000 6 2 2005 DIN EN 55032 2016 02 Class ...

Страница 8: ...AC outlet Receiver can be powered by PoE Switch Device PoE PD Supported but for safe working it recommeded to use 56VDC Power supply on Receiver When using both PoE switch Device and power supply at the same time power supply works preferentially In case of 7W camera the device supports long distance PoE transmission up to 1 200m over RG6 coaxial cable PoE transmission distance can be varied depen...

Страница 9: ... same way as step 3 a c Press Join button on the one of the device of the existing group for 2 seconds and Join LED flickers at a constant speed d Press Join button on the new device for 2 seconds and new device restarts e Join Link lights up and communications are resumed between the products Caution Please install the device following the installation guide Do not touch the device and cable with...

Отзывы: