The stove should be installed on a level floor with adequate load bearing capacity. 
The stove needs to stand on a hearth of non-combustible materials not less than 12mm thick conforming to Building 
Regulations. 
 
At least one permanent external air vent should be installed in the same room as the stove, to ensure a constant air 
supply for combustion. It should consist of a total free area of at least 3850mm².  The vent should be positioned such 
that it is not liable to blockage. 
 
NOT suitable for installation in a shared flue system. 
 
If installed in a standard type chimney, a register plate needs to be fitted inside the chimney. 
 
When purchasing flue pipe, 6” diameter is required. The flue pipe must be fitted INSIDE the flue spigot, and sealed 
with a generous amount of Fire Cement. 
 
Access should be provided for cleaning the flue to ensure that the passageways for exhaust gases remain free from 
obstruction. 
 
We recommend that you have a qualified fitter install your stove. The British recognised standard for solid fuel 
installations is HETAS. You can find a HETAS qualified installer in your area by going to the HETAS website – 

www.hetas.co.uk

.  

 
 

OPERATING INSTRUCTIONS 

 
The Clean Air Act 1993 and Smoke Control Areas 
 

Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke 
control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if 
located in a designated smoke control area. It is also an offence to acquire an “unauthorised fuel” for use within a 
smoke control area unless it is used in an “exempt” appliance (“exempted” from the controls which generally apply in 
the smoke control area). 
 
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise smokeless 
fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales this power rests with 
Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern Ireland) 
Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke 
control areas have been “authorised” in Regulations and that appliances used to burn solid fuel in those areas (other 
than “authorised” fuels) have been exempted by an Order made and signed by the Secretary of State or Minister in 
the devolved administrations. 
 
The Ekol Crystal-12 has been recommended as suitable for use in smoke control areas when burning seasoned wood. 
 
Further information on the requirements of the Clean Air Act can be found here: 

http://smokecontrol.defra.gov.uk/

 . 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of 
smoke control areas and you can contact them for details of Clean Air Act requirements. 
 

FUEL 
 

Wood- All types of wood are suitable provided they are well seasoned, UNTREATED, and have a moisture level 
between 12% and 20%. For soft woods, typically they will need to have been left in suitable storage for 9+ months in 
order for the moisture to evaporate. For hardwoods, this will usually be 18 . It is recommended that logs 
should be no more than 5” or 125mm in diameter. If you are unsure of the moisture content of your fuel, then you can 
buy a moisture meter which will indicate the moisture levels in your fuel. Liquid fuels must NEVER be used. 
 

WARNING: Wet timber should not be used as this will create excess tar deposits in the chimney and stove and could 
increase the risk of chimney fire. Timber which is not of a suitable moisture content will also create more smoke and 
harmful emissions, and will damage the stove and flue system. 

Содержание CRYSTAL-12

Страница 1: ...EKOL CRYSTAL 12 INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...ere you intend to position the stove in relation to your chimney you may wish to use the rear outlet Inside the stove will also be an ash pan which sits underneath the grate and will require regular emptying You will also find a detachable tool for removal of the ash pan You will also find a glove which must be used when opening the door or when adjusting air vents when the fire is hot INSTALLATIO...

Страница 3: ...ood and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for u...

Страница 4: ...and building work is complete The chimney is suitable and sound and has been swept and free from obstruction Adequate ventilation and provision for combustion air has been made That the stove installation has been carried out in accordance with Building Regulations and any applicable local regulations as well as these installation instructions That chimney draw has been checked and within specific...

Страница 5: ...ency of the stove Do not leave the fire unattended until flames are well established on the newly charged logs Always refuel onto hot embers If the fire has died out at the point of refuelling use kindling to re establish the fire and follow the Ignition procedure above It is important that the stove is not overloaded with fuel Reduced burn rates can be achieved by reducing the openings of the Sec...

Страница 6: ...cans can be purchased from most hardware stores Do not use regular paint which is not high temperature resistant After prolonged periods of not using the fire the stove and flue system should be checked for blockages prior to re lighting We recommend regular servicing and safety checks are carried out by a qualified engineer There must be no unauthorised modification of the appliance Use only repl...

Страница 7: ......

Отзывы: