Ekofires 1011 GRAND LED ELECTRIC Скачать руководство пользователя страница 3

5.0 SITE REQUIREMENTS 

©

2016 Focal Point Fires plc.

3

3.0 ELECTRICAL INSTALLATION REQUIREMENTS

• Never immerse the product in water or any other liquids.

• DO NOT use the appliance outdoors.

• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-

pletely cool.

• DO NOT clean the appliance with abrasive chemicals.

• Never use accessories that are not recommended or supplied by the manufacturer. It

could cause danger to the user or damage to the appliance.

• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may

result in electric shock, fire or damage to the appliance.

• DO NOT install the fire using an extension cord.

• Unplug from the mains supply if the appliance is not to be used for long periods.

2.0 APPLIANCE DATA

Weight (kg):

17.0 kg

Supply Cord:

1.8 metres

Dimensions (mm):

H 965 x W 432 x D 152

Fuse:

13Amp

Supply Voltage and rating power: 220-240V a.c. 50Hz, 1800W

Location:

Indoor Use

Heating Elements:

2 x 900Watts (1.8kW)

Lighting:

LED 

The appliance is supplied with a pre-wired three pin plug (13 Amp fuse rated), and 1.8 metre cable. A standard switched outlet/wall socket,

(including earth provision), must therefore be located within this distance, and be easily accessible in order to isolate the supply for maintenance

and cleaning.  This socket must not be mounted behind or above the appliance.   

IMPORTANT: THIS APPLIANCE MUST BE EARTHED.

1.0 PRELIMINARY NOTES - CONTINUED

GB IE

It should be noted that the appliance creates warm convected air currents. These currents move heat from the room

surroundings to, and up the wall surfaces adjacent to the heater.

Installing the heater next to these types of wall coverings or operating the heater where impurities in the air, (such as tobacco

smoke) exist, may slightly discolour wall finishing.

If the appliance is to be mounted on a dry lined or timber framed construction then the integrity and ability of the wall to

carry the weight of the appliance must be confirmed. It is important in these circumstances that any vapour barrier and/or

structural members of the house frame are not damaged.

If you are unsure of the ability of the wall to carry the weight and/or which type of wall fixing to use, you should take

professional advice and obtain the correct fixings. Alternatively, find a more suitable wall location.

DO NOT

• mount on a ceiling or floor

• recess any part of the appliance into the wall, or run the supply cable under carpets.

• site any electrical equipment e.g. plasma screen TV sets etc, on the wall below the appliance.

• site in a position where curtains or drapes could cover the appliance, or other soft materials could cover e.g. below a coat

rack

• site behind an opening door where mechanical impact/damage could occur

• site where the supply cable would become a trip hazard

• sit, stand or forcefully pull on the appliance

• obstruct, cover or force items into the openings

• use the heater to dry clothes

• site/use in an outdoor location(s)

It is important that the following clearances are maintained from the appliance to combustible materials. These clearances are

dependent on the mounting location as defined below:

4.0 COMPONENT CHECKLIST

QUANTITY

DESCRIPTION

1

Heater unit

1

Decorative glass facia

1

Remote control handset

1

Instruction Booklet

1

Bag of crystals

5

Fixing screws

Wall plugs

Содержание 1011 GRAND LED ELECTRIC

Страница 1: ...ight in the text images and layout of this booklet is owned by Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fire...

Страница 2: ...from 3 years and less than 8 years shall only switch on off the appliance pro vided that it has been placed or installed in its intended normal operating position and they have been given supervision...

Страница 3: ...gs to and up the wall surfaces adjacent to the heater Installing the heater next to these types of wall coverings or operating the heater where impurities in the air such as tobacco smoke exist may sl...

Страница 4: ...used are sufficient The appliance should not be installed until all wet plastering and or dry wall sanding and wall painting has been completed Do not block the ventilation holes of the appliance The...

Страница 5: ...wall plugs have at least one screw in a wall stud NOTE If hole locations are on studs you do not need to drill or use wall plugs simply apply screws directly into studs Lift the appliance onto the wa...

Страница 6: ...THE CRYSTAL EMBERS The glass front must be removed and the appliance must be mounted in its final location before the crystal embers are installed A Cleaning the crystals is recommended Crystal ember...

Страница 7: ...carried out before the fire can be operated NOTE The visual effect will remain operational if the cutout is activated only the fan heater is prevented from working Switch OFF the appliance at the wal...

Страница 8: ...d connections If the supply cable becomes damaged it must be replaced by a service agent or competent person such as a qualified electrician This appliance is supplied with a 3 pin plug fitted with a...

Страница 9: ...urse the costs of any third party who undertakes any work carried on the product or fits parts unless we have approved such work in advance of it being carried out The guarantee period will not be ext...