7.  Maintenance & Troubleshooting 

 

7-1. Maintenance 

To maintain accurate measurement, it is necessary to check and do the following. 

With routine maintenance and periodical calibration, MS-093 can be used for a long period of time as more 

than 10 years.    Depending on the installation and operating environment, such as near heavy traffic road 

and airport, MS-093 may get more impact from the environment.  It is highly recommended to perform 

proper maintenance for the installation and operating environment. 

 

Table 7-1. Maintenance Items 

Check Items 

Frequency 

How To 

Effects 

Clean Glass Cover

Several 

times per 

1 week 

Wipe the dirt on the glass cover by 

soft cloth and alcohol 

Solar radiation is blocked by the dirt 

on the glass cover and cause 

decrease in output. 

Check Glass Cover 

Condition 

Every 

Week 

Check glass cover for any 

movement, scratch and/or crack.   

Water may leak inside by rain drops 

and condensation causing damages 

to the sensor and internal parts. 

Check Mirror 

Rotation Condition 

Every 

Month 

Check the reflecting mirror for its 

movement; make sure it is rotating 

smoothly and not stopped or 

rotating irregularly. 

MS-093 may not output any 

sunshine signal, or may cause 

misjudgment between sunshine/not 

sunshine.  

Check Horizontal 

Level 

Every 

Week 

Check and make sure the MS-093 

base plate is in horizontal position 

and adjust the level as necessary 

Measurement error corresponding 

to the shifted incident angle will be 

accounted in the measurements. 

Check Sensor 

Latitude and Tilt 

Condition 

Every 

Month 

Check the latitude scale to check for 

any shifts in the sensor position. 

Measurement error corresponding 

to the shifted incident angle will be 

accounted in the measurements. 

Check Sensor 

Installation 

Direction 

Every 

Month 

Check the direction of MS-093 

installation direction.    Make sure it 

is facing towards the right direction.

Measurement error corresponding 

to the shifted direction angle will be 

accounted in the measurements.   

Check Silica Gel 

Condition 

Every 

Month 

Check the silica gel color change 

from blue to reddish color.    If the 

color had been changed, replace 

with new silica gel. 

Condensation may occur inside the 

glass cover due to humidity and may 

lead to misjudgment of 

sunshine/no-sunshine.  Leaving 

the without replacing silica gel may 

lead to damaging the MS-093 

Calibration 

Every 2 

Years 

Contact EKO for calibration. 

May lead to misjudgment of 

sunshine/no-sunshine. 

Overhauling 

Every 2 

Years 

Contact EKO for overhaul service to 

replace packing and O-rings which 

are used in parts of MS-093 and are 

consumable parts. 

Water leakage inside the sensor 

may occur easily, and lead to 

misjudgment of sunshine/ 

no-sunshine if not treated.   

Содержание MS-093

Страница 1: ...INSTRUCTION MANUAL MS 093 Sunshine Duration Meter...

Страница 2: ...1 WARNING CAUTION 5 4 Introduction 6 4 1 Main Functions 6 4 2 Package Contents 7 5 Getting Started 8 5 1 Sunshine Duration Meter Configuration 8 5 2 Parts Name and Descriptions 9 5 3 Installation 11 5...

Страница 3: ...el 31 0 70 3050117 Fax 31 0 70 3840607 North America Region www eko usa com info eko usa com EKO INSTRUMENTS USA Inc 95 South Market Street Suite 300 San Jose CA 95113 USA Tel 1 408 977 7751 Fax 1 408...

Страница 4: ...ollection points Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from i...

Страница 5: ...elates is in conformity with the following harmonized standards of other normative documents Harmonized standards EN 61326 1997 A1 A2 Class A Emission EN 61326 1997 A1 A2 Immunity EN61000 4 2 EN61000...

Страница 6: ...nexpected accidents Do not give an impact on exposed glass tube Do not hold the glass tube part when carrying Glass tube part may break and lead to serious injury and or accident by broken glass and o...

Страница 7: ...ve the given threshold 120W m2 Also the pyroelectric sensor has flat characteristics thus it can correspond to the changes of solar spectral distribution changes by the climate 2 Mirror The mirror ins...

Страница 8: ...rks MS 093 Main Unit 1 With Sensor Cable Standard cable length 10m Fixing Screws M5 x 2 Latitude Fixing Screw Hexagon Wrench 1 Set Includes 1 set of screw 1 hexagon wrench Reset Box 1 Optional Cable l...

Страница 9: ...ctric circuit part contains control circuit components such as motor and CPLD 3 Reset Box Optional This unit monitors the movement of the mirror and when the mirror rotation stopped it resets the powe...

Страница 10: ...93 Parts Name 1 Sensor Cable Connector 7 Latitude Scale Plate 13 Spirit Level 2 Drying Cartridge 8 Blower fan Unit Optional 14 Leveling Feet 3 Electric Circuit Part 9 Blower fan Unit Skirt 15 Blower f...

Страница 11: ...Box is not used connect the Reset Box Junction Cable directly to DC Power Supply and Data Logger See Table 5 3 Cable Colors and Outputs for details 3 Power Box Optional FG Fuse Power Supply Connector...

Страница 12: ...reflect solar radiation onto the sunshine duration meter The Sunshine Duration Meter is installed in North South direction Table 5 2 Orientation of Sunshine Duration Meter Installing Location Directio...

Страница 13: ...ne See previous section for determining the North South direction 2 Attach the Sensor Stand on the Base Plate in advance Place the Base Plate with Sensor Stand on the mounting base so that the N side...

Страница 14: ...Meter connector This connector is waterproof make sure to securely fasten the connector till the connector ring is completely closed 2 When Reset Box is used connect the Sunshine Duration Meter Senso...

Страница 15: ...ine duration signals from MS 093 uses non voltage contact signal and it makes the contact for 1 second when sunshine is detected When taking measurement by connecting to a data logger MS 093 cannot be...

Страница 16: ...eeds this threshold value it is determined as there is sunshine Moreover when the logic circuit recognizes the sunshine from the logic values which determine either sunshine or no sunshine the non vol...

Страница 17: ...ent between sunshine not sunshine Check Horizontal Level Every Week Check and make sure the MS 093 base plate is in horizontal position and adjust the level as necessary Measurement error correspondin...

Страница 18: ...ogger Mirror stopped rotating When Reset Box is not used Check the power supply make sure the power supply voltage is DC 12V If the power supply is in proper condition turn OFF the power once and put...

Страница 19: ...o 450mA 30 to 40 Operation Temperature Range 20 to 40 Sunshine Duration Outputs Output Sunshine No Sunshine Non voltage contact output Pulse Width 1 0 05sec Voltage Resistance 60V Make contact for one...

Страница 20: ...pe Power Consumption 11VA Size 200 W x 140 D x 80 H Weight Approximately 1 1kg 4 Blower Fan Unit Optional Table 8 4 Blower Fan Unit Specification Items Specifications Maximum Wind Flow Rate Approximat...

Страница 21: ...oshi NJW 2012 PF 2 Power Cable Optional 3 Reset Box Junction Cable Optional 4 Pulse Output Cable Optional To Power Box Connector 2 5m To AC Plug Figure 8 2 Power Cable Figure 8 3 Reset Box Junction Ca...

Страница 22: ...EKO INSTRUMENTS CO LTD Sunshine Duration Meter MS 093 Instruction Manual Ver 4 Pg 21 8 3 Dimensions 1 Sunshine Duration Meter MS 093 Figure 8 5 MS 093 Dimension Bottom of Sensor Stand...

Страница 23: ...EKO INSTRUMENTS CO LTD Sunshine Duration Meter MS 093 Instruction Manual Ver 4 Pg 22 2 Reset Box Optional Figure 8 6 Reset Box Dimension...

Страница 24: ...EKO INSTRUMENTS CO LTD Sunshine Duration Meter MS 093 Instruction Manual Ver 4 Pg 23 3 Power Box Optional Figure 8 7 Power Box Dimension...

Страница 25: ...Cable Cable Length 1 5m Blower Fan Unit Cable Length 10m DC12V Base Plate Base Plate Fixing Bolts Nuts 1 set includes bolts and nuts 2pcs each Table 8 6 Consumable Parts List Parts Name Used Parts Qt...

Страница 26: ...ncy of United nations who has authoritative role in standardization and control over international meteorological related activities World Radiation Reference WRR Radiometric reference instrument syst...

Страница 27: ...eko co jp EKO North America 95 South Market Street Suite 300 San Jose CA 95113 USA P 1 408 977 7751 F 1 408 977 7741 info eko usa com www eko usa com EKO Europe Middle East Africa South America Lulofs...

Отзывы: