background image

EKO INSTRUMENTS CO., LTD. Ventilation Unit MV-01 Instruction Manual Ver. 4 

Pg.  3 

2 - 3 .  A b o u t   I n s t r u c t i o n   M a n u a l  

Copy  Rights  Reserved  by  EKO  INSTRUMENTS  CO.,  LTD.    Making  copies  of  whole  or  parts  of  this 

document without permission from EKO is prohibited. 

This manual was issued: 

2019/11/11 

Version Number: 

 

 

 

2 - 4 .   E n v i r o n m e n t  

 

1.  WEEE Directive 2002/96/EC 

(Waste Electrical and Electronic Equipment) 

In August of 2005, the European Union (EU) implemented the EU WEEE Directive 2002/96/EC and later the 

WEEE  Recast  Directive  2012/19/EU  requiring  Producers  of  electronic  and  electrical  equipment  (EEE)  to 

manage  and  finance  the  collection,  reuse,  recycling  and  to  appropriately  treat  WEEE  that  the  Producer 

places  on  the  EU  market  after  August  13,  2005.  The  goal  of  this  directive  is  to  minimize  the  volume  of 

electrical and electronic waste disposal and to encourage re-use and recycling at the end of life. 

EKO  products  are  subject  to  the  WEEE  Directive  2002/96/EC.  EKO  Instruments  has  labeled  its  branded 

electronic products with the WEEE Symbol (figure Trash bin) to alert our customers that products bearing this 

label should not be disposed of in a landfill or with municipal or household waste in the EU. 

If you have purchased EKO Instruments branded electrical or electronic products in the EU and are intending 

to  discard  these  products  at  the  end  of  their  useful  life,  please  do  not  dispose  of  them  with  your  other 

household  or  municipal  waste.  Disposing  of  this  product  correctly  will  help  save  valuable  resources  and 

prevent  any  potential  negative  effects  on  human  health  and  the  environment,  which  could  otherwise  arise 

from inappropriate waste handling. 

 

2.  RoHS Directive 2002/95/EC 

EKO Instruments has completed a comprehensive evaluation of its product range to ensure compliance with 

RoHS Directive 2002/95/EC regarding maximum concentration values for substances. As a result all products 

are manufactured using raw materials that do not contain any of the restricted substances referred to in the 

RoHS Directive 2002/95/EC at concentration levels in excess of those permitted under the RoHS Directive 

2002/95/EC, or up to levels allowed in excess of these concentrations by the Annex to the RoHS Directive 

2002/95/EC. 

Содержание M V - 0 1

Страница 1: ...INSTRUCTION MANUAL MV 01 Ventilation Unit...

Страница 2: ...4 Environment 3 2 5 CE Declaration 4 3 Safety Information 5 3 1 WARNING CAUTION 5 4 Introduction 7 4 1 Main Features 7 4 2 Package Contents 8 5 Getting Started 9 5 1 Parts Name and Descriptions 9 5 2...

Страница 3: ...31 0 70 3050117 Fax 31 0 70 3840607 North America Region https eko usa com info eko usa com EKO INSTRUMENTS USA Inc 111 North Market Street Suite 300 San Jose CA 95113 USA Tel 1 408 977 7751 Fax 1 40...

Страница 4: ...ith the WEEE Symbol figure Trash bin to alert our customers that products bearing this label should not be disposed of in a landfill or with municipal or household waste in the EU If you have purchase...

Страница 5: ...er Model No MV 01 To which this declaration relates is in conformity with the following harmonized standards of other normative documents Harmonized standards EN 61326 1 2013 Class A Emission EN 61326...

Страница 6: ...ly to the base or mast with bolts and nuts otherwise the instrument may drop due to gale or earthquake which may lead to unexpected accidents Make sure the instrument and the cables are installed in a...

Страница 7: ...is an error in the type of power supply AC or DC or voltage for measurement and then connect this product If you make a mistake it may cause a failure or an accident of this product Do not supply mor...

Страница 8: ...n the sensor dome and sun screen Pyranometer with ventilator can be mounted in horizontal or tilted plane which make it suitable for PV monitoring applications The Tacho output provides a data pulse t...

Страница 9: ...ly Cable 1pc Main Body Fixing Bolts 2pcs M6 x100mm bolts used for fixing the MV 01 main body in installation position Fixing Bolts 3pcs M5 x 10mm bolts used for fixing equipment to MV 01 Fine pitch th...

Страница 10: ...s are used in cold regions and or snowy regions turn on the heater unit to prevent snow and ice getting on the glass dome and sun screen 2 Overcurrent protection Overcurrent protection is included to...

Страница 11: ...ials are used for cable and connector pin terminals are attached to the cable ends for easy connection with DC power supply and data logger If you require a longer cable than the standard 10m and or r...

Страница 12: ...it on the center of the MV 01 from above Securely fix the fixing bolt which has been passed through the fixing hole of the solar radiation sensor to the MV 01 using the supplied hex wrench 4 Adjust th...

Страница 13: ...cable are used Make sure the polarity is correct otherwise the fan will be damaged Voltage drop in AWG22 cable 0 17V 10m 2 2 Power Supply Heater Apply a power supply with a rated specification DC 12...

Страница 14: ...on The frequency of this square wave output is proportional to the rotation of the shaft The tacho signal can be measured using a frequency meter or pulse counter 12VDC Pulse signal 100Hz 2 900rpm Fix...

Страница 15: ...izontal level Cause directional response error Check Cable Monthly Check for any damages disconnection of cables and loose connector Damaged cables and or loose connectors may lead to malfunction Chec...

Страница 16: ...so check for any obstacles like trash plants and bugs are not stuck in the fan Fan RPM is low Make sure the supply voltage is appropriate Long cables cause a supply voltage drop adjust to the appropri...

Страница 17: ...sumption When DC12V input Fan 1 9W Heater 6 5W Operating Temperature Range 40 to 70 Ambient Temperature Tacho output Pulse 100Hz 2900 RPM Environmental Protection IP IP 54 equivalent IEC60529 Standard...

Страница 18: ...s the dimension of MV 01 Table 7 2 Dimensions MV 01 A Fixing Holes Pitch 120 mm B Body Height Fan Unit part 53 mm C Fixed foot 16 mm D Overall width 138 mm Use fixed foot and leveling screws which are...

Страница 19: ...es See 5 2 Installation 2 Wiring for power supply cable wiring details 7 4 Accessories List Table 7 3 Accessories List Option Items Remarks Output Cable Cable Length 20m 30m 50m Terminals Fork termina...

Страница 20: ...asia com EKO North America 111 North Market Street Suite 300 San Jose CA 95113 USA P 1 408 977 7751 F 1 408 977 7741 info eko usa com https eko usa com EKO Europe Middle East Africa South America Lul...

Отзывы: