18
9.4Maintenance, Recharging and Replacement of the accumulator
The truck must be parked in a safe location before any operation on the accumulator.
9.4.1 Maintenance Technician
Battery charging, maintenance and replacement must be operated by qualified professionals. The user manual,
supply preparation and charging requirements must be carefully read before the preparation operation.
9.4.2 Fire protection measures
When operating the battery, smoking and open flame are strictly prohibited. Storage batteries and charging should
be kept away from combustible materials, and should be kept at least 2 meters away. Places where batteries are
placed should be well ventilated and equipped with fire protection facilities.
9.4.3 Battery maintenance
1) Keep the nuts on every battery cell dry and clean. Tighten every terminal and cable end, and brush them with
grease to prevent corrosion. Naked cable ends and terminal posts should be covered with a skid-proof insulating
cover.
2) Every two cells should be well-connected. Check the nuts on each pole, if loose, tighten the nuts.
3) Keep the surfaces of accumulator clean and dry. After the completion of recharging, clean spilled acid with cotton
yarns or brush. And clean with wet towel if necessary.
4) Over recharging and over discharging should be avoided, and fast charging and insufficient recharging are also
not allowed. Otherwise life span of the accumulator may be affected.
5) Do not put conductive objects including metal tools on the accumulator, or short circuit or even explosion may be
caused.
6) Never spill any hazardous liquid or solid material on surfaces of the accumulator. When using a densimeter or a
thermometer, make sure the surface is clean and clear.
7) Recharge the discharged accumulator in time. Delayed recharging may damage the accumulator. Do not delay
recharging more than 24 hours. Recharging of the accumulator may not work outdoors in cold weather. In this case,
move it indoors to perform recharging.
8) If the accumulator will not be in use for a long time, it should be recharged and discharged once every month and
it should be fully recharged every time.
9) During recharging or using, the liquid level of electrolyte lowers because of water evaporation, so pure water
should be added. It is not allowed to add electrolyte with a specific weight of 1.280.