EK-FF1-TP

16xD.O. 16(10)A/230Vac 

~

 50/60 Hz

8xBlind 16(10)A/230Vac 

~

 50/60 Hz

4B

5B

4A

5A

6B

7B

6A

7A

3

4

1A

A

B

19

20

1B

21

22

2B

23

24

3B

25

26

4B

27

28

5B

29

30

6B

31

32

7B

33

34

8B

5

6

2A

A

B

7

8

3A

A

B

9

10

4A

A

B

11

12

5A

A

B

13

14

6A

A

B

15

16

7A

A

B

17

18

8A

A

B

1

2

L

N

bus KNX

230V~ 50/60Hz

+

L

-

N

Bus

KNX

100-230 Vac

50/60 Hz

a

Connection of KNX bus line and 100-230 Vac power supply

Connection of the loads

The  connection  of  the  controlled  loads  (fig.  b,  fig.  c)  is 

made with the screw terminals located at the top. In case 

the device is used as 8-fold blind actuator f, the terminals 

must be connected coupling the channels as follows: 1A-

1B, 2A-2B, 3A-3B, 4A-4B.
Characteristics of the terminals
•  screw clamping of conductors

•  maximum cross section of conductor 2.5 mm² (single-

wire) or 1.5 mm² (multi-wire)

•  recommended wire stripping approx. 6 mm

•  torque max 0.8 Nm

The output contacts for the up / down directions are in-

terlocked so that no voltage is applied simultaneously on 

both contacts.

Configuration and commissioning

Configuration  and  commissioning  of  the  device  require 

the use of the ETS

®

 (Engineering Tool Software) program 

V4 or later releases. These activities must be carried out 

according to the design of the building automation system 

done by a qualified planner.
Configuration
For the configuration of the device parameters the corre

-

sponding application program or the whole ekinex

®

 pro-

duct database must be loaded in the ETS program. For 

detailed information on configuration options, refer to the 

application manual of the device available on the website 

www.ekinex.com

Warning!

 Sockets controlled via bus must be cle-

arly identified. Controlling loads with mobile installa

-

tion (e.g. household appliances connected to mains 

sockets) must be planned and realized with a care-

ful evaluation of the risks that may arise in the case 

of control without direct visual contact with the load 

(remote  control).  Connecting  loads  different  than 

those planned, remote controlling without direct ve-

rification of the current conditions of the connected 

load or automatic controlling based on scenes or 

time-scheduling can cause serious damage to pe-

ople and objects. 

c

Connection of the loads (device used as 8-fold blind actuator)

b

Connection of the loads (device used as 16-fold binary output)

L

N

5A

9

10

6A

11

12

7A

13

14

8A

15

16

1A

2A

3

4

3A

5

6

4A

7

8

L

N

27

28 29

30 31

32 33

34

19

20 21

22 23

24 25

26

17

18

5B

6B

7B

8B

1B

2B

3B

4B

4

3

1A

20

19

1B

M

L

N

6

5

2A

22

21

2B

M

8

7

3A

24

23

3B

M

10

9

4A

26

25

4B

M

5A

28

27

5B

M

L

N

6A

30

29

6B

M

7A

32

31

7B

M

8A

34

33

8B

M

12

11

14

13

16

15

18

17

Product 

code

Application

program

(## = release)

Communica-

tion objects

(max nr.)

Group 

adresses

(max nr.)

EK-FF1-TP

APEKFF1TP##.knxprod

442

254

Warning!

 The electrical connection of the device 

can be carried out only by qualified personnel. The 

incorrect installation may result in electric shock or 

fire. Before making the electrical connections, make 

sure the power supply has been turned off. 

!

!

Characteristics of the terminals
•  screw clamping of conductors

•  maximum cross section of conductor 2,5 mm²

•  ecommended wire stripping approx. 6 mm

•  torque max 0,5 Nm

Commissioning
or commissioning the device the following activities are 

required: 
•  make the electrical connections as described above; 

•  turn on the bus power supply; 

•  switch the device operation to the programming mode 

by pressing the programming pushbutton located on 

the front side of the housing. In this mode of operation, 

Содержание EK-FF1-TP

Страница 1: ...h LEDs Configuration as normally opened or normally closed switch Logic gates and forced operation mode Status feedback only at bus operating Locking function for each channel Time programming delay for switching on and off stai rcase lighting function with prewarning signal Integration in scenes Counter of operating hours configurable by bus Control of blinds The device can be used for switching ...

Страница 2: ...le wire conductors and diameter between 0 6 and 0 8 mm recommended wire stripping approx 5 mm color codification red positive bus conductor black negative bus conductor Thanks to the pushbuttons located on the front of the de vice the connected loads can be manually controlled in the absence of voltage on the KNX bus or when the pro gramming has not yet been carried out and in this way it is possi...

Страница 3: ...s must be cle arly identified Controlling loads with mobile installa tion e g household appliances connected to mains sockets must be planned and realized with a care ful evaluation of the risks that may arise in the case of control without direct visual contact with the load remote control Connecting loads different than those planned remote controlling without direct ve rification of the current...

Страница 4: ...tallation electrical connection configuration and commissioning of the device can only be carried out by qualified personnel in compliance with the applicable technical standards and laws of the respective countri es Warning Incorrect disposal of this product may cause serious damage to the environment and hu man health Please be informed about the correct disposal procedures for waste collecting ...

Отзывы: