background image

4│en 

Product description 

Fig. 1: 

Overview of the system 

1 Code pad 

2 Power supply 

3 Control panel 

4 Distributor 

5 Motorised lock 

6 Cable transfer 

7 Connecting cable 

Code pad; 

Control panel; 

Operating instructions, mounting instructions, wiring diagram; 

Optional: matching accessories (cable transfer, power supply, 

connecting cable, covers, etc.). 

This product is an access control system with a non-physical identification 

feature (pin code). The system is comprised of a code pad and control 

panel. It is available in various makeups and component combinations. 

Non-physical identification features (pin codes) are entered and compared 

with the stored reference codes. If they match up, the door opens. 
The system is primarily designed for opening house doors, apartment 

doors and garage doors in homes and businesses. 

Function of the code pad 

The code pad captures the pin code by means of the capacitive keypad. It 

compares what has been entered with the stored reference code. The 

code pad can handle pin codes containing 4 to 8 digits. The digits in the 

pin code cannot all be the same; at least one of them must be different. 

There are 2 types of pin code: the admin code for configuring the system 

and the user code for opening the door. 

System 

overview 

 

Scope of 

delivery 

Proper use 

and area of 

application 

Code pad 

    www.rkdoorsystems.co.uk

Page 4

Product description

Содержание home FS OM

Страница 1: ...www rkdoorsystems co uk OpErAtInG InStructIOnS en 01 ekey home Touchpad Operating Instructions...

Страница 2: ...s and establishing normal mode 8 Entering the admin code 8 Changing the admin code 9 10 Setting the automatic back illumination 11 Setting the brightness of the back illumination 11 Setting the relay...

Страница 3: ...ices are not used within the scope of proper use Unauthorised modifications are carried out on the system devices by the operator These operating instructions are not subject to updating Subject to op...

Страница 4: ...to be operated with safety extra low ekey home voltage SELV Only use power supplies rated protection class 2 according to VDE 0140 1 Failure to do so will result in life threatening danger due to elec...

Страница 5: ...features pin codes are entered and compared with the stored reference codes If they match up the door opens The system is primarily designed for opening house doors apartment doors and garage doors i...

Страница 6: ...orrect menu item etc An acoustic signal transmitter signals that the button has been pressed and that access has been enabled The back illumination of the keypad is blue dimmable and switches on or of...

Страница 7: ...g 1 relay 1 input Integration into doors 1 relay Table 3 Control panel makeups Function of the control panel The control panel is the actuator of the system It serves to switch one relay Controls and...

Страница 8: ...eed s 1 after input is complete Operational lifetime Button presses approx 1 million Table 5 Technical specifications ekey home keypad integra 2 0 Description Unit Value ekey home CP mini 1 ekey home...

Страница 9: ...l to light up check the wiring and power supply Implementation Implementing the devices couples the control panel and the code pad with one another The following steps apply to the only ekey home CP m...

Страница 10: ...It automatically switches back to normal mode if you do not press a button within 10 s This function allows you to change the existing admin code The admin code may contain between 4 and 8 digits The...

Страница 11: ...w on the left and green on the right The status LEDs light up red The required admin code has already been assigned as a user code Enter the admin code from the beginning again 7 Enter the new admin c...

Страница 12: ...tatus LED lights up green on the left 2 Press The status LEDs light up green The status LEDs light up red Something has been entered incorrectly The brightness threshold was not changed Enter the admi...

Страница 13: ...is in normal mode The switching time for the relay can be set up to 99 9 in 0 1 second increments By default the switching time is set to 3 seconds Enter the required relay switching time in tenths o...

Страница 14: ...nd optical signals off 1 acoustic signals on and optical signals off 2 acoustic signals off and optical signals on 3 acoustic and optical signals on The signalling to indicate that a button has been p...

Страница 15: ...green on the left 2 Press The status LEDs light up green The status LEDs light up red Something has been entered incorrectly The signalling was not changed Enter the admin code from the beginning aga...

Страница 16: ...r code is already present Enter the admin code from the beginning again 4 Enter the required user code again on the keypad 5 Press The status LEDs light up green The status LEDs light up red The two e...

Страница 17: ...er 3 times there will be a 15 minute lock There will be another 15 minute lock each time the code is entered incorrectly after that NOTICE You can also open the door using the digital input PIN 7 8 on...

Страница 18: ...erably deleted The admin code is reset to the default setting 9999 the relay switching time to 3 seconds the brightness threshold to 10 and the brightness value to 100 The acoustic and optical signall...

Страница 19: ...ntrol panel This can only be undertaken mini 1 for the 1 at the factory ekey home CP micro Step Action Description Display 1 Press and hold the button with the operating rod for at least 4 seconds Sta...

Страница 20: ...e status LED lights up red on the right An incorrect user code has been entered 3 times 1 minute or 15 minute system lock After the 1 minute or 15 minute lock enter a correct user code The 1 minute or...

Страница 21: ...ekey biometric systems GmbH Translated documentation 20 en Dismantling and disposal Pursuant to Directive 2002 96 EC of the European Parliament and Council of 27 January 2003 on the sale return and e...

Отзывы: