background image

English

Deutsch

Français

中文

Instructions for Use

Important:

  Please read this “Instructions for Use”, and Installation Manual (on the 

CD-ROM) carefully to familiarize yourself with safe and effective usage. 

Please retain this manual for future reference.

• The latest 

"

Instruction for Use” is available for download from our web 

site: http://www.eizo.com

Gebrauchsanweisung

Wichtig:

 

Bitte lesen Sie diese „Gebrauchsanweisung“ und das separate 

Installationshandbuch sorgfältig durch, um sich mit dem sicheren und 

sachgemäßen Gebrauch des Produkts vertraut zu machen. 

Bewahren Sie dieses Handbuch zum späteren Nachschlagen auf.

• „Gebrauchsanweisung“ steht Ihnen auf unserer Website zum Download 

zur Verfügung: http://www.eizo.com

Mode d’emploi

Important :

  Veuillez lire attentivement ce « Mode d’emploi » ainsi que le Manuel 

d’installation (tome séparé) afin de vous familiariser avec ce produit et de 

l’utiliser efficacement et en toute sécurité. 

Veuillez conserver ce manuel pour référence ultérieure.

• La dernière version du « Mode d’emploi » est à disposition pour 

téléchargement sur notre site Web : http://www.eizo.com

设定手册

重要事项:  请仔细阅读本“使用说明书”和“安装手册”(单独卷),熟

悉安全和高效使用。请保留本手册,以备日后参考。

• 

最新“使用说明书”可在我们的网站上下载 

 http://www.eizo.com

Содержание RadiForce GX540-CL

Страница 1: ...sorgf ltig durch um sich mit dem sicheren und sachgem en Gebrauch des Produkts vertraut zu machen Bewahren Sie dieses Handbuch zum sp teren Nachschlagen auf Gebrauchsanweisung steht Ihnen auf unserer...

Страница 2: ...Instructions for Use Monochrome LCD monitor English...

Страница 3: ...or example the symbol illustrates the notification of general prohibition such as Grounding the unit This product has been adjusted specifically for use in the region to which it was originally shippe...

Страница 4: ...d proper maintenance please read carefully this section and the caution statements on the monitor Location of the Caution Statements Symbols on the unit Symbol This symbol indicates Main Power Switch...

Страница 5: ...r electric shock Use the unit in an appropriate location Not doing so may result in fire electric shock or equipment damage Do not place outdoors Do not place in the transportation system ship aircraf...

Страница 6: ...walls and others an arm stand is fixed on have adequate mechanical strength When the unit is dropped please ask your local EIZO representative for advice Do not continue using a damaged unit Using a d...

Страница 7: ...not use the unit laid down or upside down Blocking the ventilation slots prevents proper airflow and may result in fire electric shock or equipment damage Do not touch the plug with wet hands Doing s...

Страница 8: ...duce changes in luminosity caused by long term use and maintain a stable display When the screen image is changed after displaying the same image for extended periods of time an afterimage may appear...

Страница 9: ...amage the cabinet or panel Note The optional ScreenCleaner is recommended for cleaning the cabinet and panel surface The stains on the cabinet and panel surface can be removed by moistening part of a...

Страница 10: ...view 11 Using RadiCS LE ScreenManager Pro for Medical 11 1 4 Controls and Functions 12 Chapter 2 Setting Up 13 2 1 Compatible Resolutions 13 2 2 Connecting Cables 13 2 3 Adjusting the Screen Height an...

Страница 11: ...istory is included See 1 3 EIZO LCD Utility Disk page 11 The software ScreenManager Pro for Medical to adjust the screen using the mouse and keyboard is included See 1 3 EIZO LCD Utility Disk page 11...

Страница 12: ...n EIZO LCD Utility Disk CD ROM is supplied with this product The following table shows the disk contents and the overview of the software programs Disk contents and software overview The disk includes...

Страница 13: ...or Measures the environmental illumination 8 Integrated Front Sensor slide type Used for calibration and Grayscale Check 9 Main power switch Turns the main power on or off 10 Power connector Connects...

Страница 14: ...les Attention Check that the monitor and the PC are powered off When replacing the current monitor with this monitor be sure to change the PC settings for resolution and vertical scan frequency to tho...

Страница 15: ...ts up green 6 Turn on the PC The screen image appears If an image does not appear refer to Chapter 3 Troubleshooting page 15 for additional advice Attention Turn off the monitor and PC after using the...

Страница 16: ...a problem Solve the problem turn off the monitor and then turn it on again Refer to the User s Manual of the output device for further details 2 The message below appears This message appears when the...

Страница 17: ...brightness may be higher than the target brightness Raise the target brightness 34 The sensor may not have come out during calibration or light may have entered the sensor Turn off the main power wait...

Страница 18: ...lection is set to Manual DC5V Output is set to Off and DP Power Save is set to On Power Off 0 5 W or less when no USB device is connected DC5V Output is set to Off and DP Power Save is set to On Main...

Страница 19: ...71 209 5 8 2 245 5 9 7 15 0 59 355 14 0 30 TILT 629 24 8 173 6 8 320 12 6 236 9 3 3 0 12 512 20 2 146 5 5 8 105 4 1 350 13 8 455 17 9 30 TILT 65 5 2 58 99 3 90 99 3 90 94 5 3 72 171 6 7 161 6 3 549 21...

Страница 20: ...DVI D connector for digital signal input only The other is a DVI I connector for both digital and analog signal inputs DVI DMPM DVI Digital Monitor Power Management DVI DMPM is a digital interface po...

Страница 21: ...NEC Corporation PC 9801 and PC 9821 are trademarks of NEC Corporation NextWindow is a registered trademark of NextWindow Ltd Intel Intel Core and Pentium are registered trademarks of Intel Corporation...

Страница 22: ...waves that could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment where such effects are avoided Classification of Equipment Type of protectio...

Страница 23: ...mful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tele...

Страница 24: ...estic purposes Harmonic emissions IEC EN61000 3 2 Class D Voltage fluctuations flicker emissions IEC EN61000 3 3 Complies Guidance and manufacturer s declaration electromagnetic immunity The RadiForce...

Страница 25: ...transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the foll...

Страница 26: ...of transmitter W Separation distance according to frequency of transmitter m 150kHz to 80MHz d 1 2 P 80MHz to 800MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2...

Страница 27: ...ied period of time since the date of manufacture The label is attached to the back of the device Name and Concentration of Hazardous Substances Component Name Hazardous Substance Name Lead Pb Mercury...

Страница 28: ...40 4 8 5B Phone 86 512 6252 0100 Fax 86 512 6252 1508 153 Shimokashiwano Hakusan Ishikawa 924 8566 Japan Phone 81 76 277 6792 Fax 81 76 277 6793 Siemensallee 84 76187 Karlsruhe Germany Phone 49 721 20...