background image

Quality Control Sensor

Digital Mammography Monitor

Quality Control Tool

Four options are available:

Displaying the Optimum Digital Mammography Image

EIZO offers all the necessary components for correct digital mammography image display.

Bit

Compatible Operating System

Frame Buffer Memory

Bus Interface

Maximum Disply Resolutions

Output Terminals

Dot Clock

Scanning Frequency (H, V)

Maximum Power Consumption

12-bit /10-bit / 8-bit
Windows XP / 2000 Professional
128 MB
PCI 32-bit (33 MHz / 66 MHz)
2048 x 2560
DVI-I x 2
Up to 148 MHz
103.9 kHz
50 Hz
16.8 watts

High-Performance Graphics Board

Standard Configuration

10-bit / 8-bit
Windows XP / 2000 Professional
256 MB
PCI 32-bit (33 MHz) / 64-bit (66 MHz)
2048 x 2560
DVI-I x 2
Up to 148 MHz
103.9 kHz
50 Hz
40 watts

8-bit
Windows XP
1 GB
PCI Express x 16
2048 x 2560
DVI-D x 2
214.25 MHz
131 kHz
50 Hz
75 watts

8-bit
Windows XP
256 MB
PCI Express x 16 / x 1
2048 x 2560
DVI-D x 2
162 MHz
75 kHz
60 Hz
22 watts

Accessories

Monitor Cleaning Kit

Keep your screen free from dust and fingerprints with 
this screen cleaner kit. Includes pump spray and cloth. 
(Bundled with GS520-CLG and GS520-BLG.)

Panel Protector

Protect against scratches and dust with high light 
transmission panel.

Dual Height Adjustable Stand

Mount two panels in either portrait or landscape 
orientation.

5

6

■ 

PAS 1054

“ Requirements and Testing of Digital Mammography 
Equipment ” established by the Normenausschusses 
Radiologie (DIN NAR) in cooperation with the Deutschen 
Röntgengesellschaft (DRG) and others. In line with the 
QS-RL (Qualitätssicherungs-Richtlinie) quality assurance 
ordinance, it is mandatory in Germany to refer to this 
standard when conducting monitor quality assurance.

EIZO's easy-to-use RadiCS quality control 
software performs precise calibration conforming 
to DICOM Part 14 and enables quality control 
complying with ACR Practice Guideline and 
other QC standard for digital mammography 
monitors.

Once attached to the top of the monitor the 
Clip-On Swing Sensor G1 can remain in place 
and is ready for use. This saves the time and 

trouble of attaching 
a n d   r e m o v i n g   i t  
w h e n p e r f o r m i n g
quality control tasks. 

Quality Control of Digital Mammography Monitor

As with the use of film mammography, image quality testing of 
the monitor at installation and regularly during use should be 
carried out. This ensures that the monitor maintains a consistent 
display of quality digital mammography.

● 

An option of  

An option of  clear 

clear base and 

base and 

blue

blue base backlights are available.

 base backlights are available.

● 

Paired monitors which provides the same 

Paired monitors which provides the same 

color and grayscale for two monitors 

color and grayscale for two monitors 
bundled as a pair in one box, also available.

bundled as a pair in one box, also available.

 

ACR “Practice Guideline for Determinants of Image

  

Quality in Digital Mammography” 

A guideline established by the American College of Radiology 
(ACR) in cooperation with the American Association of 
Physicists in Medicine (AAPM), Radiological Society of North 
America (RSNA), and Society for Imaging Informatics in 
Medicine (SIIM).

 

EUREF “European Guidelines for Quality Assurance 

    in Breast Cancer Screening and Diagnosis”

A  s t a n d a r d   i s s u e d   b y   t h e   E u r o p e a n   C o m m i s s i o n   i n  
cooperation with the European Reference Organization for 
Quality Assured Breast Screening and Diagnostic Services 
(EUREF), and European Breast Cancer Network (EBCN), 
European Society of Mastology (EUSOMA).

Содержание Digital Mammography Monitor

Страница 1: ......

Страница 2: ...rol Software For unified image display between multiple monitors the monitor is required to adjust the characteristics to the grayscale standard DICOM Part 14 through calibration Simple Quality Control Procedures Quality characteristics gradually change over time and therefore in order to maintain a consistent display the monitor needs to be quality controllable Image Sharpness For detection of su...

Страница 3: ...ding high definition and high density display without shadings appearing granular C T 512 512 1024 1280 1600 1200 2048 1536 Mammography 1914 2294 Chest CR 1760 2150 2560 2048 D S A 1000 1000 Displaying only 72 DUE for Brightness Uniformity Input Level 80 204 255 CCD Camera Brightness Map Input Level 80 204 255 CCD Camera Brightness Map 100 70 lower 100 70 lower EIZO s confidence in its product qua...

Страница 4: ...to refer to this standard when conducting monitor quality assurance EIZO s easy to use RadiCS quality control software performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors Once attached to the top of the monitor the Clip On Swing Sensor G1 can remain in place and is ready fo...

Страница 5: ...gonal 540 mm 2048 x 2560 0 165 x 0 165 mm 4 096 from a palette of 13 771 tones 170 170 700 cd m2 typical 500 cd m2 800 1 typical 100 ms typical 31 135 kHz 19 51 Hz Frame synchronous mode 49 51 Hz 300 MHz DVI Standard 1 0 DVI D 24 pin 1 upstream 2 downstream Standard Rev 2 0 AC 100 120 V 200 240 V 50 60 Hz 90 watts Less than 1 2 watts Backlight Sensor DVI DMPM English French German Italian Japanese...

Отзывы: