Selecting the Optimum 
Digital Mammography Monitor

High-Resolution

High resolutions are required to display the correct 
“information volume” of a digital mammography image.

High-Definition & High-Density

For the detection of mammary gland disorders which 
appear as “distortion,” the monitor needs this required 
performance in order to display the subtle structures.

Multi-Grayscale

For the detection of small tumors which appear as delicate 
“density” differences, the monitor needs the correct display 
of extremely subtle grayscale shadings.

DICOM Part 14 Compliance 
with Quality Control Software

For unified image display between multiple monitors, the monitor is 
required to adjust the characteristics to the grayscale standard DICOM 
Part 14 through calibration.

Simple Quality Control Procedures

Quality characteristics gradually change over time and therefore in order to 
maintain a consistent display, the monitor needs to be quality-controllable.

Image Sharpness

For detection of subtle masses and calcifications, the 
monitor needs to display the outlines of the images with a 
high degree of sharpness.

Brightness Uniformity

For correct luminance display of delicate “density” 
differences, the monitor needs uniformity in brightness 
across the entire screen.

1

2

1

Requirement

2

Requirement

3

Requirement

4

Requirement

5

Requirement

6

Requirement

7

Requirement

Содержание Digital Mammography Monitor

Страница 1: ......

Страница 2: ...rol Software For unified image display between multiple monitors the monitor is required to adjust the characteristics to the grayscale standard DICOM Part 14 through calibration Simple Quality Control Procedures Quality characteristics gradually change over time and therefore in order to maintain a consistent display the monitor needs to be quality controllable Image Sharpness For detection of su...

Страница 3: ...ding high definition and high density display without shadings appearing granular C T 512 512 1024 1280 1600 1200 2048 1536 Mammography 1914 2294 Chest CR 1760 2150 2560 2048 D S A 1000 1000 Displaying only 72 DUE for Brightness Uniformity Input Level 80 204 255 CCD Camera Brightness Map Input Level 80 204 255 CCD Camera Brightness Map 100 70 lower 100 70 lower EIZO s confidence in its product qua...

Страница 4: ...to refer to this standard when conducting monitor quality assurance EIZO s easy to use RadiCS quality control software performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors Once attached to the top of the monitor the Clip On Swing Sensor G1 can remain in place and is ready fo...

Страница 5: ...gonal 540 mm 2048 x 2560 0 165 x 0 165 mm 4 096 from a palette of 13 771 tones 170 170 700 cd m2 typical 500 cd m2 800 1 typical 100 ms typical 31 135 kHz 19 51 Hz Frame synchronous mode 49 51 Hz 300 MHz DVI Standard 1 0 DVI D 24 pin 1 upstream 2 downstream Standard Rev 2 0 AC 100 120 V 200 240 V 50 60 Hz 90 watts Less than 1 2 watts Backlight Sensor DVI DMPM English French German Italian Japanese...

Отзывы: