background image

IC

: (Hardwire Interconnect- normally not used

except to hardwire interconnect to mains smoke
alarms which don’t have an Ei168 

RadioLINK

Base)

The alarm does not need to be earthed.  However the
earth terminal is provided for the convenience of the
installers so that any earth wire or cable coloured green
or green & yellow, can be safety terminated.

Note: House wiring should not be  bunched up  in
the area of the alarms but quickly directed away.
This will minimize their effect on the radio aerial.

7. Replace the wiring cover.

8. Remove the required Smoke/ Heat Alarm from
the box (discard the mounting plate supplied).
Carefully line up the smoke/heat alarm on the
Ei168 

RadioLINK

Base and slide it on 

(see fig 4).

9. Connect the mains power to the alarm circuit.
Check the green light is on.  If the amber light
flashes every 10 seconds, remove the alarm
(see figure 5 on  how to remove alarm ) and
manually depress the rechargeable cell "on"
switch as shown in figure 7 and replace the
alarm. If there is still a problem the cells may be

SLIDE

ON

5

WARNING:

 DISCONNECT MAINS

BEFORE REMOVING ALARM

Figure 5

Figure 4

Содержание RadioLINK Ei168

Страница 1: ...al for use with Smoke Heat Alarms Contains vital information on the products operation and installation Read and retain carefully If you are just installing this product the manual MUST be given to th...

Страница 2: ...TINGTHE REPEATER FUNCTION 5 TROUBLESHOOTING RF LINK 6 LIMITATIONSOF RADIO COMMUNICATIONS 7 CHECKING MAINTAININGYOUR SMOKEALARMSYSTEM 8 GETTINGYOUR RadioLINK BASESERVICED 9 FIVEYEARGUARANTEE 10 TECHNIC...

Страница 3: ...he Ei168 RadioLINK Base This will auto matically activate the rechargeable back up cells Repeat this procedure for all alarms in the system see page 5 1 3 To House Code insert a small screwdriver into...

Страница 4: ...se will normally be wired to the nearest mains circuit in the ceiling usually the lighting circuit provided unswitched live is available The Smoke Heat Alarm is then slid on to the RadioLINK Base rath...

Страница 5: ...ying with the advice in the Smoke Heat Alarm instruction leaflet 2 Disconnect the AC mains supply from the circuit that is going to be used 3 Carefully align the RadioLINK Base and screw into place as...

Страница 6: ...surface a position the mounting plate so the cable trunking is as shown in figure 3 b Carefully cut and trim the knockouts in the RadioLINK Base side walls to blend with the contours of the trunking...

Страница 7: ...ill minimize their effect on the radio aerial 7 Replace the wiring cover 8 Remove the required Smoke Heat Alarm from the box discard the mounting plate supplied Carefully line up the smoke heat alarm...

Страница 8: ...perty within 15 minutes before the timeout period expires If any other RadioLINK accessories are to be used they must also be put into the house code mode at this time see their instructions leaflets...

Страница 9: ...arms with nearby systems Finally attach the label provided to the distribution board to identify the alarm circuits Note To clear house codes see section 10 Technical Specification 4 ACTIVATING THE RE...

Страница 10: ...er Note To deactivate the Repeater function see section 10 Technical Specification 5 TROUBLESHOOTING RF LINK If when checking the radio link interconnection some of the alarms do not respond to the bu...

Страница 11: ...ange of existing units even though they may have already been house coded correctly in the system It is important therefore to check that all detectors are communicating in their final installed posit...

Страница 12: ...operating frequencies regardless of the house coding The Ei168 RadioLINK Base has been tested to EN 300 220 1 V1 3 1 200 09 in accordance with the requirements of EN 300 220V1 1 1 2000 09 These tests...

Страница 13: ...on If it is off check circuit breakers fuses and wiring etc Check the red light on the cover flashes every 40 seconds ii Press the test hush button for up to 20 seconds on each unit The horn will soun...

Страница 14: ...ins rechargeable cell back up is checked directly after installation and then at least yearly as follows i Check that the amber light on the side of the RadioLINK Base is not flashing once every 10 se...

Страница 15: ...n installed correctly and is receiving AC power green light on in smoke heat alarms contact Customer Assistance at the nearest address given at the end of this leaflet If it needs to be returned for r...

Страница 16: ...g Your RadioLINK Base Serviced We shall at our discretion repair or replace the faulty unit Do not interfere with the RadioLINK Base or attempt to tamper with it This will invalidate the guarantee but...

Страница 17: ...em A maximum number of 12 Ei168 units can communicate together on one system however the range is likely to be the limiting factor in many cases Communication All units will communicate together as sh...

Страница 18: ...signal range Activating the Repeater Function Press and hold the test button until the alarm sounds and the amber light comes on then immediately while the light is on press and hold the House Code sw...

Страница 19: ...locate RF linked Smoke Heat Alarms Ei428 RadioLINK RELAY MODULE This module is a device that switches a relay upon receipt of an alarm signal from a suitable Ei smoke heat alarm Ei407 RadioLINK MANUAL...

Страница 20: ...ess Park Maesbury Road Oswestry Shropshire SY10 8NN U K Telephone 0870 7584000 www aico co uk Ei Electronics Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 61 471277 www eielectronic...

Отзывы: