The  following  procedures  should  be  followed  to  test  the  RM85  for  correct 
operation: 
 

 

1. 

After  unpacking,  examine  all  external  features  to  confirm  damage-
free shipment. Report all defects and damage at once.  Connect the 
power cable to a grounded 15 Amp electrical outlet. 

 
 

2. 

Check dehumidification process as follows: 

 

 
 

 

A. 

Place unit on a level surface. 

 

 

B. 

Start up unit by switching to “I”. 

 

 

C.   Check that the compressor is running. 

 

 

D. 

Leave the machine running for 15 minutes. 

 

 

E.   Observe the evaporator coils through the front grille, to confirm 

frost formation. 

 

   

 

i. If the air temperature is below 78

°

F, an even coating of frost 

should cover the entire evaporator coil.   

   

 

ii. If the air temperature is above 78

°

F, frost and/or droplets of 

condensed water should cover the entire evaporator coil. 

 

   

F. 

When  the  unit  is  operated  in  ambient  of  less  than  59°F,  a 
defrost  cycle  should  occur  approximately  every  hour.  The 
exact  time  is  impossible  to  predict  as  the  unit  is  fitted  with  a 
temperature sensitive defrost control. 

 

If, after carrying out the above procedures, the unit does not appear to 

function properly, refer to the 

Trouble Shooting

 section, which follows, 

or contact the Factory Service Center. 

 
 
 
 
 
 
 
After using the RM85, turn it off for five minutes to allow the condensate on 
the coils to drain into the pump reservoir, then press the momentary pump 
purge switch for twenty to thirty seconds to evacuate the water from the pump 
reservoir. 

CAUTION: 

DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION 

CAUTION: 

ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT 

LEAST FIVE MINUTES BEFORE RESTARTING. 

Содержание rm85

Страница 1: ...Page 1 of 12 Drawing TPC408 Issue 3 Date 08 08 14 RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...2 of 12 Drawing TPC408 Issue 3 Date 08 08 14 RM85 PACKAGE CONTENTS Item Description Quantity 10560RG US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC408 Manua...

Страница 3: ...air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradua...

Страница 4: ...erants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data labe...

Страница 5: ...l ii If the air temperature is above 78 F frost and or droplets of condensed water should cover the entire evaporator coil F When the unit is operated in ambient of less than 59 F a defrost cycle shou...

Страница 6: ...e covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5...

Страница 7: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 8: ...as 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Contact the Factory Ser...

Страница 9: ...3 1 6 Filter 2056004 1 7 Capillary 3014254 2 X 2ft 8 Solenoid valve 3020837 1 9 Filter dryer 3020909 1 10 Compressor 3022198 1 11 Defrost Relay 3030269 1 12 Solenoid coil 3030451 1 13 Hour meter 30307...

Страница 10: ...Page 10 of 12 Drawing TPC408 Issue 3 Date 08 08 14...

Страница 11: ...Page 11 of 12 Drawing TPC408 Issue 3 Date 08 08 14...

Страница 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: