Drawing   : - TPC476 
Issue 

: - 2 

Date 

: - 11/04/19 

 

OPERATION 

 
After unpacking, examine all external features to confirm damage-free 
shipment. Report all defects and damage at once. 
 
Connect the drainage outlet to a suitably sized hose and run the hose to a 
permanent drain. 
 
Connect to a grounded 13A electrical outlet. To protect the compressor, you 
should allow 5 minutes between switching the dehumidifier off and on again. 
 

 

CHECK DEHUMIDIFICATION PROCESS AS FOLLOWS: 

 

 
1.  Place unit on a level surface. 
2.  Start up unit by switching to “I” and humidistat fully clockwise 
3.  Check that the compressor is running. 

 

4.  Leave the machine running for 15 minutes. 
5.  Observe  the  evaporator  coils  through  the  rear  grille,  to  confirm  frost 

formation or weeping. 

  If the air temperature is below 25

°

C, an even coating of frost should 

cover the entire evaporator coil. 

  If the air temperature is above 25

°

C, frost and/or droplets of 

condensed water should cover the entire evaporator coil. 

 
6.  When  the  unit  is  operated  in  ambient  of  less  than  15°C,  a  defrost  cycle 

should  occur  approximately  every  hour.  The  exact  time  is  impossible  to 
predict as the unit is fitted with a temperature sensitive defrost control. 

 

If, after carrying out the above procedures, the unit does not appear to 

function properly, refer to the 

Trouble Shooting

 section, which follows, 

or contact the Factory Service Center. 

 
 
 
 
 
 
 

CAUTION: 

DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION 

CAUTION: 

ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT 

LEAST FIVE MINUTES BEFORE RESTARTING. 

Содержание BD75P

Страница 1: ...Page 1 of 12 Drawing TPC476 Issue 2 Date 11 04 19 BD75P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...phase plus the additional heat generated by the compressor The air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered...

Страница 3: ...al GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the p...

Страница 4: ...e the evaporator coils through the rear grille to confirm frost formation or weeping If the air temperature is below 25 C an even coating of frost should cover the entire evaporator coil If the air te...

Страница 5: ...ng accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains cable for damage or loose connections 5 In order t...

Страница 6: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 7: ...fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass va...

Страница 8: ...019712 1 5 Capillary 3014251 1 64ft 6 Solenoid valve 3020836 1 7 Filter dryer 3020937 1 8 Solenoid coil 3030452 1 9 On Off switch 3035914 1 10 Fan Motor 3947013 1 11 Fan Blade 3947014 1 12 Castor 3050...

Страница 9: ...to Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407...

Страница 10: ...Page 10 of 12 Drawing TPC476 Issue 2 Date 11 04 19...

Страница 11: ...Page 11 of 12 Drawing TPC476 Issue 2 Date 11 04 19...

Страница 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: