EIPL 10149BR-US Скачать руководство пользователя страница 13

 

 

 

 

Page 13 of 16 

Drawing   : - TPC575 
Issue 

: - 1 

Date 

: - 08/02/22 

 
 
 

WARNINGS

  

 

 

This appliance can be used by children from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or instruction concerning 

use of the application in a safe way and understand the hazards involved. 

 

Children shall not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children without 

supervision. 

 

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, 

its service agent or similarly qualified person in order to avoid hazard. 

 

This product contains fluorinated greenhouse gases covered by the Kyoto 

Protocol. The refrigeration system is hermetically sealed. 

 

The Global Warming Potential (GWP) of refrigerants used in products 

manufactured by Ebac Industrial Products Ltd is as follows 

R134a – 1300 

R407c – 1610 

 

For type and weight of refrigerant contained in this unit, please refer to the 

product data label 

 

Due to the high pressures within the refrigeration circuit, under no 

circumstances must direct heat be applied to the evaporator coil in an attempt 

to remove the build-up of ice. 

 

No attempt should be made to cut open any part of the refrigeration circuit 

due to high pressures and gas involved. 

 

If the unit is switched off at the mains power supply for any reason, the unit 

must be allowed to stand at rest for at least three minutes before restarting. 

 

Содержание 10149BR-US

Страница 1: ...Page 1 of 16 Drawing TPC575 Issue 1 Date 08 02 22 CD425 10149BR US INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...Page 2 of 16 Drawing TPC575 Issue 1 Date 08 02 22 CD425 PACKAGE CONTENTS Item Description Quantity 10149BR US Dehumidifier 1 3944110 Reinforced tubing 16mm I D 1 TPC575 Manual 1...

Страница 3: ...n tray for collecting and disposing of condensed moisture f A cabinet to house the above components The fan draws the moist air through the evaporator coils which cools the air below its dew point Moi...

Страница 4: ...igerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data la...

Страница 5: ...NOTE after the pump has emptied there will still be a small amount of water standing in the pump reservoir which will leak if the dehumidifier is not kept upright POSITIONING The CD425 is designed fo...

Страница 6: ...r blows out of the top of the machine 3 Check dehumidification process a Remove front cover b Check actual relative humidity inside the area c Set humidity control to a lower value than the actual rel...

Страница 7: ...sed water should cover the entire evaporator coil 4 Leave the unit to run for approximately 42minutes from compressor starting after which the unit should go through a 4 minute defrost cycle During th...

Страница 8: ...covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5...

Страница 9: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 10: ...g diagram to find fault and repair Little or no water extraction 1 Insufficient air movement 2 Compressor fault 3 Loss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the...

Страница 11: ...Contactor Compressor 3030321 1 Auxiliary contact Fan 3030322 1 Solenoid Coil 3030454 1 Transformer 230V 12V 3031144 1 Transformer 460V 220V 3031173 1 Terminal Block 3031418 1 Overload 3032623 1 Coil...

Страница 12: ...H OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS S...

Страница 13: ...d This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products man...

Страница 14: ...Page 14 of 16 Drawing TPC575 Issue 1 Date 08 02 22...

Страница 15: ...Page 15 of 16 Drawing TPC575 Issue 1 Date 08 02 22...

Страница 16: ...state Bishop Auckland County Durham DL14 9AD Tel 44 0 1388 664400 Fax 44 0 1388 662590 www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite...

Отзывы: