Drawing   : - TPC442 
Issue 

: - 2 

Date 

: - 24/11/16 

 

WARNINGS

  

 

 

This appliance can be used by children from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or instruction concerning 

use of the application in a safe way and understand the hazards involved. 

 

Children shall not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children without 

supervision. 

 

If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, 

its service agent or similarly qualified person in order to avoid hazard. 

 

This product contains fluorinated greenhouse gases covered by the Kyoto 

Protocol. The refrigeration system is hermetically sealed. 

 

The Global Warming Potential (GWP) of refrigerants used in products 

manufactured by Ebac Industrial Products Ltd is as follows 

R134a – 1300 

R407c – 1610 

 

For type and weight of refrigerant contained in this unit, please refer to the 

product data label 

 

Due to the high pressures within the refrigeration circuit, under no 

circumstances must direct heat be applied to the evaporator coil in an attempt 

to remove the build-up of ice. 

 

No attempt should be made to cut open any part of the refrigeration circuit 

due to high pressures and gas involved. 

 

If  the  unit  is  switched  off  at  the  mains  power  supply  for  any  reason,  the  unit 

must be allowed to stand at rest for at least three minutes before restarting. 

 

For correct installation and operation the unit inlet and outlet must have a 

clearance of 0.5M from all adjacent surfaces and or structures. 

Содержание 10560HD-GB

Страница 1: ...Page 1 of 16 Drawing TPC442 Issue 2 Date 24 11 16 DUAL VOLTAGE RM85 H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...ly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area The RM85H de...

Страница 3: ...n be seen through the hole Using a flat blade screwdriver move the switch lever down to the 230 volt position If 110 volt is required the switch lever must be in the upper position Once the required v...

Страница 4: ...ing once back shell is removed The voltage selection switch is located on the rear of the electrical panel hanging from the fan deck Choose the correct voltage for the mains supply your unit will be c...

Страница 5: ...GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the prod...

Страница 6: ...ing conditioned The required humidity level can be set as follows Press the S button once to access the set point Press the or button to change the display to the desired Humidity level Press the S bu...

Страница 7: ...nd the display will return to its normal reading when the unit returns to dehumidifying mode Fan running If after carrying out the above procedures the unit does not appear to function properly refer...

Страница 8: ...ng accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains cable for damage or loose connections 5 In order t...

Страница 9: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 10: ...nt air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty...

Страница 11: ...ry 3014254 2 X 2ft 8 Solenoid valve 3020837 1 9 Filter dryer 3020909 1 10 Compressor 3022198 1 11 Defrost Relay 3030269 1 12 Voltage selection capacitor 3030375 1 13 Solenoid coil 3030451 1 14 Humidit...

Страница 12: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Страница 13: ...Page 13 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 14: ...Page 14 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 15: ...Page 15 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 16: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: