INTRODUCTION 

 

Designed  for  a  wide  range  of  applications,  the  RM85H  is  a  rugged,  industrial  unit, 
which  utilizes  an  energy-efficient  compressor  and  a  compact  portable  design  to 
provide easy efficient drying. 
 
 
The RM85 has a number of special features: 
 

 

High efficiency rotary compressor 

 

EIPL’s  “

Hot Gas

” defrost system 

 

Hours run meter 

 

Integral pump out system 

 

Provision for permanent drainage 

 

Robust rotational moulded polyethylene housing 

 

Extra long power cord 

 

Separate outlets allowing dry air to be ducted 

 
The  fan  draws  the  moist  air  through  the  cold  evaporator  coil,  which  cools  the  air 
below  its  dew  point.    Moisture  forms  on  the  evaporator  coil  and  is  collected  in  the 
condensate  tray,  which  is  equipped  with  a  permanent  drain.    The  cooled  air  then 
passes  through  the  hot  condenser  coil  where  it  is  reheated  using  the  same  energy 
removed  during  the  cooling  phase,  plus  the  additional  heat  generated  by  the 
compressor.    The  air  is,  therefore,  discharged  from  the  dehumidifier  at  a  slightly 
higher  temperature  with  a  lower  absolute  humidity  than  that  which  entered.  
Continuous  circulation  of  air  through the  dehumidifier gradually  reduces the  relative 
humidity within the area. 
 
The  RM85H  dehumidifier  is  a  rugged,  reliable  drying  unit  designed  to  operate 
effectively over a broad range of temperature and humidity conditions.  An active hot 
gas  defrost  system,  controlled  by  an  electronic  timer,  guarantees  positive  de-icing, 
thereby optimizing operation at low temperatures. 
 

A  digital  Humidistat  is  included  which  allows  for  precise  humidity  control.  A 
programmable display lets you set a specific desired humidity level.

 

 
The  unit  incorporates  a  rotational  moulded  polyethylene  shell  resilient  to  damage 
caused by rough handling. 
 
The  unit  is  fitted  with  a  transformer  which  will  allow  the  unit  to  operate  on  either 
110volts or 230volts 1ph 50Hz power supply. The unit is factory set at 110 volts. 
 
All electrical components within the unit are rated for 110volts, for safety reasons.  
 
The unit can easily be adjusted to operate from a 230 volt power supply as follows: 
 

Warning: ensure the unit is switched OFF and isolated form the supply. 
 

The  voltage  selector  switch  is  located  at  the rear  of  the machine  –  see diagram  on 
Page 4. 
 

Содержание 10560HD-GB

Страница 1: ...Page 1 of 16 Drawing TPC442 Issue 2 Date 24 11 16 DUAL VOLTAGE RM85 H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...ly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area The RM85H de...

Страница 3: ...n be seen through the hole Using a flat blade screwdriver move the switch lever down to the 230 volt position If 110 volt is required the switch lever must be in the upper position Once the required v...

Страница 4: ...ing once back shell is removed The voltage selection switch is located on the rear of the electrical panel hanging from the fan deck Choose the correct voltage for the mains supply your unit will be c...

Страница 5: ...GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the prod...

Страница 6: ...ing conditioned The required humidity level can be set as follows Press the S button once to access the set point Press the or button to change the display to the desired Humidity level Press the S bu...

Страница 7: ...nd the display will return to its normal reading when the unit returns to dehumidifying mode Fan running If after carrying out the above procedures the unit does not appear to function properly refer...

Страница 8: ...ng accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains cable for damage or loose connections 5 In order t...

Страница 9: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 10: ...nt air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty...

Страница 11: ...ry 3014254 2 X 2ft 8 Solenoid valve 3020837 1 9 Filter dryer 3020909 1 10 Compressor 3022198 1 11 Defrost Relay 3030269 1 12 Voltage selection capacitor 3030375 1 13 Solenoid coil 3030451 1 14 Humidit...

Страница 12: ...oto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R40...

Страница 13: ...Page 13 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 14: ...Page 14 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 15: ...Page 15 of 16 Drawing TPC442 Issue 2 Date 24 11 16...

Страница 16: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Отзывы: