GB
- 19 -
12. Possible causes of failure
Fault
Cause
Remedy
The equipment
does not work
- No electrical voltage at the equip-
ment
- The cross section of the extension
cable is not large enough and/or
the extension cable is too long
- The mains voltage is lower than
that speci
fi
ed
- The pump is frozen
- Check the fuse, power cable and
power plug and have them replaced
by quali
fi
ed personnel if necessary
- Use extension cables with larger
cross sections and/or use shorter
extension cables
- Contact the power supply company
if necessary
- Check and thaw if necessary
The motor starts but
there is no pressure
build-up
- The water intake
fi
lter is clogged
- Air intake in the water inlet
- The discharge nozzle is too large
- Water cock closed
- Clean the water intake
fi
lter (see
8.2.1)
- Check the supply hose and hose
connectors and replace if necessa-
ry
- Check and replace if necessary
- Turn open the water cock.
The operating pres-
sure is irregular
- Air intake in the water inlet
- Check the supply hose and hose
connectors and replace if necessa-
ry
Anl_SA_TC_HP_1334_SPK8.indb 19
Anl_SA_TC_HP_1334_SPK8.indb 19
25.04.16 10:29
25.04.16 10:29
Содержание TC-HP 1334
Страница 25: ... 25 Anl_SA_TC_HP_1334_SPK8 indb 25 Anl_SA_TC_HP_1334_SPK8 indb 25 25 04 16 10 29 25 04 16 10 29 ...
Страница 26: ... 26 Anl_SA_TC_HP_1334_SPK8 indb 26 Anl_SA_TC_HP_1334_SPK8 indb 26 25 04 16 10 29 25 04 16 10 29 ...
Страница 27: ... 27 Anl_SA_TC_HP_1334_SPK8 indb 27 Anl_SA_TC_HP_1334_SPK8 indb 27 25 04 16 10 29 25 04 16 10 29 ...
Страница 28: ...EH 04 2016 01 Anl_SA_TC_HP_1334_SPK8 indb 28 Anl_SA_TC_HP_1334_SPK8 indb 28 25 04 16 10 29 25 04 16 10 29 ...