Check the mains lead at regular intervals for
signs of defects or damage. A damaged mains
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
앬
The device must not be installed in laundries.
앬
The device must be installed so that the plug is
accessible.
앬
The temperature in the cooling circuit may
become very hot. You should therefore keep all
cables away from the copper pipes.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
2. Items supplied
Split 2503 EQ C+H
1 indoor device (box 1, art. no. 23.654.18)
1 outdoor device (box 2, art. no. 23.654.19)
1 set of installation accessories (for details, see page
20)
Split 3500 EQ C+H
1 indoor device (box 1, art. no. 23.654.36)
1 outdoor device (box 2, art. no. 23.654.37)
1 set of installation accessories (for details, see page
20)
3. Technical data
Split 2500 EQ C+H
Cooling capacity
2600 watts
Heating capacity
2800 watts
Energy efficiency
B (EER 3.09/COP 3.33)
Air capacity
410 m
3
/h
Absorbed humidity (30°C/80%RH)
1.0 l/h
Timer 24
h
Operating voltage
220 - 240 V ~ 50 Hz
Socket fusing
16 A
Nominal power consumption, cooling
840 watts
Nominal current consumption, cooling
3.7 A
Nominal power consumption, heating
830 watts
Nominal current consumption, heating
3.7 A
Compressor Rotary
piston
Compressor starting current
22 A
Outdoor temperature, cooling operation °C
+18 - +43 (DB)
Outdoor temperature, heating operation °C
-7 - + 24 (DB)
Fluid line Ø A
6.35 mm
Suction pipe Ø A
9.53 mm
Length of refrigerant line supplied
5 m
Length of refrigerant line, max.
10 m
Max. difference in height between indoor/outdoor
device
5 m
Refrigerant
R 410 A
Refrigerant filling capacity
730 g
Refrigerant refill quantity from 5 m
20 g/m
Sound pressure level
Inside
≤ 39 dB (A)
Outside
≤ 53 dB (A)
Dimension Inside
79 x 27,5 x 19 cm
Dimension Outside
78 x 54 x 25 cm
Weight Inside
8,5 kg
Weight Outside
28 kg
Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 12
Содержание Split 2500 EQ C+H
Страница 4: ...4 8 9 12 13 10 11 A Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 53 Uhr Seite 4...
Страница 5: ...5 15 14 16 A 780 mm C D 17 Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 54 Uhr Seite 5...
Страница 6: ...6 18 19 23 21 22 20 A B X X Y Y Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 54 Uhr Seite 6...
Страница 8: ...8 31 30 34 33 35 32 B B A A Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 54 Uhr Seite 8...
Страница 30: ...30 Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 54 Uhr Seite 30...
Страница 31: ...31 Anleitung_Split_2500 3500_EQ_C_H_GB _ 10 12 2008 11 54 Uhr Seite 31...