11. Troubleshooting
Fault
Possible causes
Remedies
The motor fails to
start
a) Motor terminals disconnected
b) The mower is standing in high
grass
c) The mower housing is clogged
d) Safety switch is not inserted
e) Battery is not correctly inserted
f) Insu
ffi
cient or no contact between
the handle and the handle fastener
(Fig. 3 / Section 5).
a) Have repaired by the Customer
Service Center
b) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary
c) Clean the housing so that the blade
moves freely
d) Insert safety switch (see 6.)
e) Remove the battery and reinsert
(see 5.)
f) Undo the handle connection, check
the contacts for dirt and carefully
clean with a brush. Tighten the
handle connection (see 5).
The motor perfor-
mance drops
a) The grass is too high or too damp
b) The mower housing is clogged
c) The blade is severely worn
d) Battery performance decrea-
sing
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
d) Check the battery performance
and charge the battery if necessary
(see 5.)
Cutting is irregular
a) The blade is worn
b) Wrong cutting height
a) Replace or resharpen the blade
b) Correct the cutting height
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period
Anl_Rasarro_SPK9.indb 30
Anl_Rasarro_SPK9.indb 30
14.11.2018 10:50:49
14.11.2018 10:50:49
Содержание RASARRO
Страница 192: ... 192 Anl_Rasarro_SPK9 indb 192 Anl_Rasarro_SPK9 indb 192 14 11 2018 10 51 11 14 11 2018 10 51 11 ...
Страница 193: ... 193 Anl_Rasarro_SPK9 indb 193 Anl_Rasarro_SPK9 indb 193 14 11 2018 10 51 11 14 11 2018 10 51 11 ...
Страница 194: ...EH 11 2018 01 Anl_Rasarro_SPK9 indb 194 Anl_Rasarro_SPK9 indb 194 14 11 2018 10 51 11 14 11 2018 10 51 11 ...